Manufacturer: DualSun SAS Registry: CEC Verified Engineering Specification

DualSun SAS DualSun 310M-60-00 is a 310.0 W STC (283.3 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 18.9% efficiency, 40.3 V Voc at 25 C, and 44.24 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
283.3 W
Voc @ 25C
40.3 V
Efficiency
18.9%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does DualSun SAS DualSun 310M-60-00 Compare Against Peer CEC Listings?

Solar engineering breakdown for DualSun SAS DualSun 310M-60-00: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from DualSun SAS and peers, DualSun SAS DualSun 310M-60-00 stands 100.0 W below the 410.0 W Mono-c-Si median and typical 91.4% PTC-to-STC thermal output (283.3 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Mid-range 40.3 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does DualSun SAS DualSun 310M-60-00 Fall Across Listed CEC Models?

Distribution marker showing DualSun SAS DualSun 310M-60-00 (310.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where DualSun SAS DualSun 310M-60-00 (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCDualSun SAS DualSu: 310.0 W

What Dataset Percentiles Define DualSun SAS DualSun 310M-60-00?

Dataset percentiles tracking DualSun SAS DualSun 310M-60-00 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

DualSun SAS DualSun 310M-60-00 Engineering BenchmarksPercentile comparison of DualSun SAS DualSun 310M-60-00 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention91.4%Module Efficiency18.9%

What Do the Dataset Ranks Show for DualSun SAS DualSun 310M-60-00?

Benchmark highlights for DualSun SAS DualSun 310M-60-00 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,649

18.9% Aperture Efficiency

Power density 189.0 W/m2 (1.01 percentage points below 19.91% CEC median). PTC/STC ratio: 91.4% (rank #15,834).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.24 V at -10 C (575.1 V string) and 45.36 V at -20 C (13 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 42.6 m2 (459 sq ft) producing 7,366 W PTC; NEC 690.8 OCPD floor is 15.57 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.3 * (1 + (-0.279/100) * (-10 - 25)) = 44.24 V | OCPD = 1.56 * 9.98 = 15.57 A

Inputs from CEC Modules.csv for DualSun SAS DualSun 310M-60-00: Voc=40.3 V, beta_Voc=-0.279%/C, Isc=9.98 A, STC=310.0 W, Area=1.64 m2.

Result: 13 panels max on 600 V (575.1 V); 26 panels for 8 kW (459 sq ft).

What Are the Published CEC Specifications for DualSun SAS DualSun 310M-60-00?

Official CEC datasheet figures for DualSun SAS DualSun 310M-60-00 (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for DualSun SAS DualSun 310M-60-00.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 283.3 W (91.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.98 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.2 V / 9.35 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.279 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.9% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many DualSun SAS DualSun 310M-60-00 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many DualSun SAS DualSun 310M-60-00 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 353 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 459 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 583 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This DualSun SAS Series?

Consolidated DualSun SAS wattage variants sharing the DualSun SAS DualSun 310M-60-00 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the DualSun SAS DualSun 310M-60-00 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
DualSun SAS DualSun 300M-60-00 300.0 W 272.9 W 40.1 V 32.8 V 18.29%
DualSun SAS DualSun 305M-60-00 305.0 W 278.6 W 40.2 V 33.0 V 18.6%
DualSun SAS DualSun 310M-60-00 310.0 W 283.3 W 40.3 V 33.2 V 18.9%
DualSun SAS DualSun 315M-60-00 315.0 W 288.0 W 40.5 V 33.4 V 19.21%
DualSun SAS DualSun 320M-60-00 320.0 W 292.7 W 40.8 V 33.6 V 19.51%

How Many DualSun SAS DualSun 310M-60-00 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on DualSun SAS DualSun 310M-60-00 (44.24 V at 14 F).

Computed from Voc=40.3V and beta_Voc=-0.279%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.36 V 13 panels 589.7 V 22 panels
-10 C (14 F) 44.24 V 13 panels 575.1 V 22 panels
0 C (32 F) 43.11 V 13 panels 560.4 V 23 panels
25 C (77 F STC) 40.3 V 14 panels 564.2 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to DualSun SAS DualSun 310M-60-00?

Competing CEC solar panels closest to DualSun SAS DualSun 310M-60-00 in nameplate wattage and Voc, starting with Bluesun Solar Energy Tech CoLtd BSM310M-60.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM310M-60
Bluesun Solar Energy Tech CoLtd
310.0 W Tie (0 W) 40.18 V 19.02% 91.9%
Boviet Solar Technology Co Ltd BVM6610M-310
Boviet Solar Technology Co Ltd
310.0 W Tie (0 W) 40.1 V 19.05% 92.2%
Boviet Solar Technology Co Ltd BVM6610M-310-H
Boviet Solar Technology Co Ltd
310.0 W Tie (0 W) 40.1 V 19.02% 93.1%
Boviet Solar Technology Co Ltd BVM6610M-W5-310-H
Boviet Solar Technology Co Ltd
310.0 W Tie (0 W) 40.1 V 19.05% 93.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for DualSun SAS DualSun 310M-60-00?

Evaluate DualSun SAS DualSun 310M-60-00 (310.0 W STC, 40.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), DualSun SAS DualSun 310M-60-00 reaches 45.36 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 459 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (459 sq ft).
  • 2026 tax credit baseline: cash residential installs of DualSun SAS DualSun 310M-60-00 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

DualSun SAS DualSun 310M-60-00 8 kW Residential Fit

Needs 26 modules (459 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM310M-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 283.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for DualSun SAS DualSun 310M-60-00 by DualSun SAS grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for DualSun SAS DualSun 310M-60-00?

Multiplying DualSun SAS DualSun 310M-60-00's 9.98 A short-circuit current by 1.56 equals 15.57 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can DualSun SAS DualSun 310M-60-00 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.24 V cold Voc at 14 F and handles 9.98 A Isc; string inverters cap DualSun SAS DualSun 310M-60-00 at 13 panels on 600 V.

Is DualSun SAS DualSun 310M-60-00 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of DualSun SAS DualSun 310M-60-00 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.