DualSun SAS DualSun 310M-60-00 is a 310.0 W STC (283.3 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 18.9% efficiency, 40.3 V Voc at 25 C, and 44.24 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 283.3 W
- Voc @ 25C
- 40.3 V
- Efficiency
- 18.9%
How Does DualSun SAS DualSun 310M-60-00 Compare Against Peer CEC Listings?
Solar engineering breakdown for DualSun SAS DualSun 310M-60-00: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from DualSun SAS and peers, DualSun SAS DualSun 310M-60-00 stands 100.0 W below the 410.0 W Mono-c-Si median and typical 91.4% PTC-to-STC thermal output (283.3 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Mid-range 40.3 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does DualSun SAS DualSun 310M-60-00 Fall Across Listed CEC Models?
Distribution marker showing DualSun SAS DualSun 310M-60-00 (310.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define DualSun SAS DualSun 310M-60-00?
Dataset percentiles tracking DualSun SAS DualSun 310M-60-00 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for DualSun SAS DualSun 310M-60-00?
Benchmark highlights for DualSun SAS DualSun 310M-60-00 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.9% Aperture Efficiency
Power density 189.0 W/m2 (1.01 percentage points below 19.91% CEC median). PTC/STC ratio: 91.4% (rank #15,834).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.24 V at -10 C (575.1 V string) and 45.36 V at -20 C (13 max).
26 Panels = 8,060 W STC
Occupies 42.6 m2 (459 sq ft) producing 7,366 W PTC; NEC 690.8 OCPD floor is 15.57 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.3 * (1 + (-0.279/100) * (-10 - 25)) = 44.24 V | OCPD = 1.56 * 9.98 = 15.57 A
Inputs from CEC Modules.csv for DualSun SAS DualSun 310M-60-00: Voc=40.3 V, beta_Voc=-0.279%/C, Isc=9.98 A, STC=310.0 W, Area=1.64 m2.
Result: 13 panels max on 600 V (575.1 V); 26 panels for 8 kW (459 sq ft).
What Are the Published CEC Specifications for DualSun SAS DualSun 310M-60-00?
Official CEC datasheet figures for DualSun SAS DualSun 310M-60-00 (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 283.3 W (91.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.2 V / 9.35 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.9% (1.64 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many DualSun SAS DualSun 310M-60-00 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many DualSun SAS DualSun 310M-60-00 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 353 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 459 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 583 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This DualSun SAS Series?
Consolidated DualSun SAS wattage variants sharing the DualSun SAS DualSun 310M-60-00 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| DualSun SAS DualSun 300M-60-00 | 300.0 W | 272.9 W | 40.1 V | 32.8 V | 18.29% |
| DualSun SAS DualSun 305M-60-00 | 305.0 W | 278.6 W | 40.2 V | 33.0 V | 18.6% |
| DualSun SAS DualSun 310M-60-00 | 310.0 W | 283.3 W | 40.3 V | 33.2 V | 18.9% |
| DualSun SAS DualSun 315M-60-00 | 315.0 W | 288.0 W | 40.5 V | 33.4 V | 19.21% |
| DualSun SAS DualSun 320M-60-00 | 320.0 W | 292.7 W | 40.8 V | 33.6 V | 19.51% |
How Many DualSun SAS DualSun 310M-60-00 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on DualSun SAS DualSun 310M-60-00 (44.24 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.36 V | 13 panels | 589.7 V | 22 panels |
| -10 C (14 F) | 44.24 V | 13 panels | 575.1 V | 22 panels |
| 0 C (32 F) | 43.11 V | 13 panels | 560.4 V | 23 panels |
| 25 C (77 F STC) | 40.3 V | 14 panels | 564.2 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to DualSun SAS DualSun 310M-60-00?
Competing CEC solar panels closest to DualSun SAS DualSun 310M-60-00 in nameplate wattage and Voc, starting with Bluesun Solar Energy Tech CoLtd BSM310M-60.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM310M-60 Bluesun Solar Energy Tech CoLtd |
310.0 W | Tie (0 W) | 40.18 V | 19.02% | 91.9% |
| Boviet Solar Technology Co Ltd BVM6610M-310 Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.05% | 92.2% |
| Boviet Solar Technology Co Ltd BVM6610M-310-H Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.02% | 93.1% |
| Boviet Solar Technology Co Ltd BVM6610M-W5-310-H Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.05% | 93.1% |
What Are the Design Limits and Best-Fit Uses for DualSun SAS DualSun 310M-60-00?
Evaluate DualSun SAS DualSun 310M-60-00 (310.0 W STC, 40.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), DualSun SAS DualSun 310M-60-00 reaches 45.36 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 459 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (459 sq ft).
- 2026 tax credit baseline: cash residential installs of DualSun SAS DualSun 310M-60-00 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
DualSun SAS DualSun 310M-60-00 8 kW Residential Fit
Needs 26 modules (459 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM310M-60.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 283.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for DualSun SAS DualSun 310M-60-00 by DualSun SAS grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for DualSun SAS DualSun 310M-60-00?
Multiplying DualSun SAS DualSun 310M-60-00's 9.98 A short-circuit current by 1.56 equals 15.57 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can DualSun SAS DualSun 310M-60-00 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.24 V cold Voc at 14 F and handles 9.98 A Isc; string inverters cap DualSun SAS DualSun 310M-60-00 at 13 panels on 600 V.
Is DualSun SAS DualSun 310M-60-00 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of DualSun SAS DualSun 310M-60-00 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)