Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SM295M (FB) — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SM295M (FB) is a 295.0 W STC (271.6 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.1% efficiency, 40.21 V Voc at 25 C, and 44.19 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
271.6 W
Voc @ 25C
40.21 V
Efficiency
18.1%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SM295M (FB) Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SM295M (FB) handles rooftop heat (271.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR SM295M (FB) exhibits 9.5 A short-circuit current, requiring a 14.82 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #16,890 of 21,677 (115.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 45.6 m2 for an 8 kW system (34 panels for 10 kW). Mid-range 40.21 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does PEIMAR SM295M (FB) Fall Across Listed CEC Models?

Where PEIMAR SM295M (FB) (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SM295M (FB) (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SM295M (FB): 295.0 W

What Dataset Percentiles Define PEIMAR SM295M (FB)?

Percentile placement of PEIMAR SM295M (FB) across power density (181.0 W/m2), thermal retention, and nameplate STC wattage.

PEIMAR SM295M (FB) Engineering BenchmarksPercentile comparison of PEIMAR SM295M (FB) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention92.1%Module Efficiency18.1%

What Do the Dataset Ranks Show for PEIMAR SM295M (FB)?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SM295M (FB) specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,938

18.1% Aperture Efficiency

Power density 181.0 W/m2 (1.81 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.19 V at -10 C (574.5 V string) and 45.33 V at -20 C (13 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 45.6 m2 (491 sq ft) producing 7,605 W PTC; NEC 690.8 OCPD floor is 14.82 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.21 * (1 + (-0.283/100) * (-10 - 25)) = 44.19 V | OCPD = 1.56 * 9.5 = 14.82 A

Inputs from CEC Modules.csv for PEIMAR SM295M (FB): Voc=40.21 V, beta_Voc=-0.283%/C, Isc=9.5 A, STC=295.0 W, Area=1.63 m2.

Result: 13 panels max on 600 V (574.5 V); 28 panels for 8 kW (491 sq ft).

What Are the Published CEC Specifications for PEIMAR SM295M (FB)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SM295M (FB).

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SM295M (FB).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 271.6 W (92.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.21 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.95 V / 8.98 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.283 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.1% (1.63 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SM295M (FB) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SM295M (FB) (295.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 368 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 491 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 597 sq ft $2,510 $4,245

How Many PEIMAR SM295M (FB) Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SM295M (FB) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.21V and beta_Voc=-0.283%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.33 V 13 panels 589.3 V 22 panels
-10 C (14 F) 44.19 V 13 panels 574.5 V 22 panels
0 C (32 F) 43.05 V 13 panels 559.6 V 23 panels
25 C (77 F STC) 40.21 V 14 panels 562.9 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SM295M (FB)?

Alternative CEC solar modules from competing brands near PEIMAR SM295M (FB) (295.0 W), including GCL System Integration Technology Co Ltd GCL-M6/60295.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M6/60295
GCL System Integration Technology Co Ltd
295.0 W Tie (0 W) 39.3 V 18.1% 90.2%
CSI Solar Co Ltd CS3K-295MS
CSI Solar Co Ltd
295.0 W Tie (0 W) 39.1 V 18.4% 93.0%
CertainTeed CT290M10-02
CertainTeed
290.0 W -5.0 W 39.77 V 17.83% 91.8%
CertainTeed CT290M11-02
CertainTeed
290.0 W -5.0 W 39.77 V 17.83% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SM295M (FB)?

Evaluate PEIMAR SM295M (FB) (295.0 W STC, 40.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SM295M (FB) reaches 45.33 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 491 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (491 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SM295M (FB) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SM295M (FB) 8 kW Residential Fit

Needs 28 modules (491 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 271.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SM295M (FB) by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits.

Why is PEIMAR SM295M (FB) PTC wattage (271.6 W) lower than STC (295.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 271.6 W PTC (92.1% retention) across PEIMAR SM295M (FB)'s 1.63 m2 aperture.

Who should skip PEIMAR SM295M (FB) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 PEIMAR SM295M (FB) panels (491 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-M6/60295.

What is the 1,000 V commercial string limit for PEIMAR SM295M (FB)?

On 1,000 V commercial inverters at -10 C (44.19 V cold Voc), PEIMAR SM295M (FB) fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SM295M (FB).

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.