CSI Solar Co Ltd CS3K-295MS is a 295.0 W STC (274.3 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.4% efficiency, 39.1 V Voc at 25 C, and 43.1 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 274.3 W
- Voc @ 25C
- 39.1 V
- Efficiency
- 18.4%
How Does CSI Solar Co Ltd CS3K-295MS Compare Against Peer CEC Listings?
Solar engineering breakdown for CSI Solar Co Ltd CS3K-295MS: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 295.0 W STC and 274.3 W PTC, CSI Solar Co Ltd CS3K-295MS sits -90.0 W vs all-CEC median (below all-CEC median; higher than 20.4% of peers) among 21,677 listed modules. Power density reaches 184.0 W/m2 (1.51 percentage points below 19.91% CEC median). Lower 39.1 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-M6/60295 rates 295.0 W.
Where Does CSI Solar Co Ltd CS3K-295MS Fall Across Listed CEC Models?
Distribution marker showing CSI Solar Co Ltd CS3K-295MS (295.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CSI Solar Co Ltd CS3K-295MS?
Dataset percentiles tracking CSI Solar Co Ltd CS3K-295MS power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS3K-295MS?
Benchmark highlights for CSI Solar Co Ltd CS3K-295MS covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.4% Aperture Efficiency
Power density 184.0 W/m2 (1.51 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.1 V at -10 C (560.3 V string) and 44.24 V at -20 C (13 max).
28 Panels = 8,260 W STC
Occupies 44.9 m2 (483 sq ft) producing 7,680 W PTC; NEC 690.8 OCPD floor is 15.18 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.1 * (1 + (-0.292/100) * (-10 - 25)) = 43.1 V | OCPD = 1.56 * 9.73 = 15.18 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS3K-295MS: Voc=39.1 V, beta_Voc=-0.292%/C, Isc=9.73 A, STC=295.0 W, Area=1.603 m2.
Result: 13 panels max on 600 V (560.3 V); 28 panels for 8 kW (483 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS3K-295MS?
Official CEC datasheet figures for CSI Solar Co Ltd CS3K-295MS (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 274.3 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.3 V / 9.14 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.292 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.4% (1.603 m2) | Array roof footprint density |
| Cell Count & Technology | 3 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS3K-295MS Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CSI Solar Co Ltd CS3K-295MS modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 362 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 483 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 587 sq ft | $2,510 | $4,245 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Consolidated CSI Solar Co Ltd wattage variants sharing the CSI Solar Co Ltd CS3K-295MS mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3K-290MS | 290.0 W | 269.5 W | 38.9 V | 32.1 V | 18.09% |
| CSI Solar Co Ltd CS3K-295MS | 295.0 W | 274.3 W | 39.1 V | 32.3 V | 18.4% |
How Many CSI Solar Co Ltd CS3K-295MS Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CSI Solar Co Ltd CS3K-295MS (43.1 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.24 V | 13 panels | 575.1 V | 22 panels |
| -10 C (14 F) | 43.1 V | 13 panels | 560.3 V | 23 panels |
| 0 C (32 F) | 41.95 V | 14 panels | 587.3 V | 23 panels |
| 25 C (77 F STC) | 39.1 V | 15 panels | 586.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS3K-295MS?
Competing CEC solar panels closest to CSI Solar Co Ltd CS3K-295MS in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/60295.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/60295 GCL System Integration Technology Co Ltd |
295.0 W | Tie (0 W) | 39.3 V | 18.1% | 90.2% |
| GCL System Integration Technology Co Ltd GCL-M6/60290 GCL System Integration Technology Co Ltd |
290.0 W | -5.0 W | 39.1 V | 17.79% | 90.2% |
| GCL System Integration Technology Co Ltd GCL-P6/60290 GCL System Integration Technology Co Ltd |
290.0 W | -5.0 W | 39.1 V | 17.79% | 90.7% |
| CertainTeed CT290M10-01 CertainTeed |
290.0 W | -5.0 W | 38.8 V | 17.72% | 90.9% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS3K-295MS?
Evaluate CSI Solar Co Ltd CS3K-295MS (295.0 W STC, 39.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS3K-295MS reaches 44.24 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 483 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (483 sq ft).
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS3K-295MS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS3K-295MS 8 kW Residential Fit
Needs 28 modules (483 sq ft) with a 20 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 274.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS3K-295MS by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many CSI Solar Co Ltd CS3K-295MS panels fit on a 600 V winter solar string?
At -10 C (14 F), CSI Solar Co Ltd CS3K-295MS cold Voc rises from 39.1 V to 43.1 V (beta_Voc -0.292%/C), capping a 600 V string at 13 panels (560.3 V).
How much roof area does an 8 kW array of CSI Solar Co Ltd CS3K-295MS need?
An 8 kW DC system uses 28 CSI Solar Co Ltd CS3K-295MS modules (8,260 W STC / 7,680 W PTC), covering roughly 483 sq ft and saving ~$2,067/yr at 18.54 c/kWh.
How does CSI Solar Co Ltd CS3K-295MS compare against GCL System Integration Technology Co Ltd GCL-M6/60295?
CSI Solar Co Ltd CS3K-295MS outputs 295.0 W STC (39.1 V Voc, rank #16,890 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/60295 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)