PEIMAR SG320M is a 320.0 W STC (288.2 W PTC) Mono-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 16.49% efficiency, 44.9 V Voc at 25 C, and 50.23 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 320.0 W
- PTC Wattage
- 288.2 W
- Voc @ 25C
- 44.9 V
- Efficiency
- 16.49%
How Does PEIMAR SG320M Compare Against Peer CEC Listings?
Solar engineering breakdown for PEIMAR SG320M: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Across 5,889 Mono-c-Si listings from PEIMAR and peers, PEIMAR SG320M stands 90.0 W below the 410.0 W Mono-c-Si median and typical 90.1% PTC-to-STC thermal output (288.2 W real-world rating). Sizing 6 kW (19 panels) to 10 kW (32 panels) yields $1,522-$2,563/yr in baseline US bill offset. Mid-range 44.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does PEIMAR SG320M Fall Across Listed CEC Models?
Distribution marker showing PEIMAR SG320M (320.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define PEIMAR SG320M?
Dataset percentiles tracking PEIMAR SG320M power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for PEIMAR SG320M?
Benchmark highlights for PEIMAR SG320M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
320.0 W STC · Higher Than 29.0%
320.0 W STC (-65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.49% Aperture Efficiency
Power density 164.9 W/m2 (3.42 percentage points below 19.91% CEC median). PTC/STC ratio: 90.1% (rank #18,772).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.23 V at -10 C (552.5 V string) and 51.75 V at -20 C (11 max).
25 Panels = 8,000 W STC
Occupies 48.5 m2 (522 sq ft) producing 7,205 W PTC; NEC 690.8 OCPD floor is 14.63 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.9 * (1 + (-0.339/100) * (-10 - 25)) = 50.23 V | OCPD = 1.56 * 9.38 = 14.63 A
Inputs from CEC Modules.csv for PEIMAR SG320M: Voc=44.9 V, beta_Voc=-0.339%/C, Isc=9.38 A, STC=320.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (552.5 V); 25 panels for 8 kW (522 sq ft).
What Are the Published CEC Specifications for PEIMAR SG320M?
Official CEC datasheet figures for PEIMAR SG320M (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 320.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 288.2 W (90.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.38 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.5 V / 8.77 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.339 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.49% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many PEIMAR SG320M Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many PEIMAR SG320M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.08 kW | 397 sq ft | $1,522 | $2,573 |
| 8 kW Class | 25 | 8.0 kW | 522 sq ft | $2,002 | $3,386 |
| 10 kW Class | 32 | 10.24 kW | 668 sq ft | $2,563 | $4,334 |
How Many PEIMAR SG320M Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on PEIMAR SG320M (50.23 V at 14 F). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.75 V | 11 panels | 569.2 V | 19 panels |
| -10 C (14 F) | 50.23 V | 11 panels | 552.5 V | 19 panels |
| 0 C (32 F) | 48.71 V | 12 panels | 584.5 V | 20 panels |
| 25 C (77 F STC) | 44.9 V | 13 panels | 583.7 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG320M?
Competing CEC solar panels closest to PEIMAR SG320M in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3U-320P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3U-320P CSI Solar Co Ltd |
320.0 W | Tie (0 W) | 45.1 V | 16.67% | 92.3% |
| Centrosolar America TM7 320SW Centrosolar America |
320.0 W | Tie (0 W) | 45.6 V | 16.41% | 90.9% |
| Centrosolar America TM7S 320SW Centrosolar America |
320.0 W | Tie (0 W) | 45.6 V | 16.41% | 90.9% |
| CertainTeed CT320P00-01 CertainTeed |
320.0 W | Tie (0 W) | 45.7 V | 17.68% | 91.8% |
What Are the Design Limits and Best-Fit Uses for PEIMAR SG320M?
Evaluate PEIMAR SG320M (320.0 W STC, 44.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG320M reaches 51.75 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of PEIMAR SG320M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR SG320M 8 kW Residential Fit
Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-320P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 288.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR SG320M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What fuse or breaker size does NEC 690.8 require for PEIMAR SG320M?
Multiplying PEIMAR SG320M's 9.38 A short-circuit current by 1.56 equals 14.63 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SG320M before finalizing component orders.
Can PEIMAR SG320M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.23 V cold Voc at 14 F and handles 9.38 A Isc; string inverters cap PEIMAR SG320M at 11 panels on 600 V.
Is PEIMAR SG320M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SG320M rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)