Skip to main content
WireAndSun
Calculators
CEC PV Module

CertainTeed CT320P00-01 — CEC Solar Module Specifications

Manufacturer: CertainTeed Registry: CEC Verified Engineering Specification

CertainTeed CT320P00-01 is a 320.0 W STC (293.6 W PTC) Multi-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 17.68% efficiency, 45.7 V Voc at 25 C, and 50.34 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
320.0 W
PTC Wattage
293.6 W
Voc @ 25C
45.7 V
Efficiency
17.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CertainTeed CT320P00-01 Compare Against Peer CEC Listings?

Solar engineering breakdown for CertainTeed CT320P00-01: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Across 1,407 Multi-c-Si listings from CertainTeed and peers, CertainTeed CT320P00-01 stands 41.2 W above the 278.8 W Multi-c-Si median and strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677). Sizing 6 kW (19 panels) to 10 kW (32 panels) yields $1,522-$2,563/yr in baseline US bill offset. Mid-range 45.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does CertainTeed CT320P00-01 Fall Across Listed CEC Models?

Distribution marker showing CertainTeed CT320P00-01 (320.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CertainTeed CT320P00-01 (320.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCertainTeed CT320P: 320.0 W

What Dataset Percentiles Define CertainTeed CT320P00-01?

Dataset percentiles tracking CertainTeed CT320P00-01 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

CertainTeed CT320P00-01 Engineering BenchmarksPercentile comparison of CertainTeed CT320P00-01 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage320.0 WPTC/STC Retention91.8%Module Efficiency17.68%

What Do the Dataset Ranks Show for CertainTeed CT320P00-01?

Benchmark highlights for CertainTeed CT320P00-01 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #14,944 / 21,677

320.0 W STC · Higher Than 29.0%

320.0 W STC (-65.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,541

17.68% Aperture Efficiency

Power density 176.8 W/m2 (2.23 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.34 V at -10 C (553.7 V string) and 51.66 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,000 W STC

Occupies 45.2 m2 (487 sq ft) producing 7,340 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.7 * (1 + (-0.29/100) * (-10 - 25)) = 50.34 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for CertainTeed CT320P00-01: Voc=45.7 V, beta_Voc=-0.29%/C, Isc=9.0 A, STC=320.0 W, Area=1.81 m2.

Result: 11 panels max on 600 V (553.7 V); 25 panels for 8 kW (487 sq ft).

What Are the Published CEC Specifications for CertainTeed CT320P00-01?

Official CEC datasheet figures for CertainTeed CT320P00-01 (Multi-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed CT320P00-01.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 320.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 293.6 W (91.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.4 V / 8.8 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.29 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.68% (1.81 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many CertainTeed CT320P00-01 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many CertainTeed CT320P00-01 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.08 kW 370 sq ft $1,522 $2,573
8 kW Class 25 8.0 kW 487 sq ft $2,002 $3,386
10 kW Class 32 10.24 kW 623 sq ft $2,563 $4,334

How Many CertainTeed CT320P00-01 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on CertainTeed CT320P00-01 (50.34 V at 14 F). Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Computed from Voc=45.7V and beta_Voc=-0.29%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.66 V 11 panels 568.3 V 19 panels
-10 C (14 F) 50.34 V 11 panels 553.7 V 19 panels
0 C (32 F) 49.01 V 12 panels 588.1 V 20 panels
25 C (77 F STC) 45.7 V 13 panels 594.1 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to CertainTeed CT320P00-01?

Competing CEC solar panels closest to CertainTeed CT320P00-01 in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-P6/72320.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/72320
GCL System Integration Technology Co Ltd
320.0 W Tie (0 W) 45.8 V 16.49% 90.6%
GCL System Integration Technology Co Ltd GCL-P6/72B320
GCL System Integration Technology Co Ltd
320.0 W Tie (0 W) 45.8 V 16.49% 90.2%
Centrosolar America TM7 320SW
Centrosolar America
320.0 W Tie (0 W) 45.6 V 16.41% 90.9%
Centrosolar America TM7S 320SW
Centrosolar America
320.0 W Tie (0 W) 45.6 V 16.41% 90.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CertainTeed CT320P00-01?

Evaluate CertainTeed CT320P00-01 (320.0 W STC, 45.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CertainTeed CT320P00-01 reaches 51.66 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 487 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (487 sq ft).
  • 2026 tax credit baseline: cash residential installs of CertainTeed CT320P00-01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CertainTeed CT320P00-01 8 kW Residential Fit

Needs 25 modules (487 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72320.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 293.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed CT320P00-01 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

What fuse or breaker size does NEC 690.8 require for CertainTeed CT320P00-01?

Multiplying CertainTeed CT320P00-01's 9.0 A short-circuit current by 1.56 equals 14.04 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for CertainTeed CT320P00-01 before finalizing component orders.

Can CertainTeed CT320P00-01 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.34 V cold Voc at 14 F and handles 9.0 A Isc; string inverters cap CertainTeed CT320P00-01 at 11 panels on 600 V.

Is CertainTeed CT320P00-01 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CertainTeed CT320P00-01 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.