PEIMAR SG310P is a 310.0 W STC (281.0 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.98% efficiency, 44.65 V Voc at 25 C, and 49.81 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 281.0 W
- Voc @ 25C
- 44.65 V
- Efficiency
- 15.98%
How Does PEIMAR SG310P Compare Against Peer CEC Listings?
How PEIMAR PEIMAR SG310P handles rooftop heat (281.0 W PTC), 8 kW sizing, and cold winter string voltage.
PEIMAR builds the PEIMAR SG310P (Multi-c-Si) as a compact residential or specialty off-grid module delivering 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). Compared against Anhui Rinengzhongtian Semiconductor Development QJM310-72 (310.0 W), this model holds typical 90.6% PTC-to-STC thermal output (281.0 W real-world rating). Mid-range 44.65 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.26 A overcurrent floor served by a 15 A breaker.
Where Does PEIMAR SG310P Fall Across Listed CEC Models?
Where PEIMAR SG310P (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define PEIMAR SG310P?
Percentile placement of PEIMAR SG310P across power density (159.8 W/m2), thermal retention, and nameplate STC wattage. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for PEIMAR SG310P?
Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SG310P specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.98% Aperture Efficiency
Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.81 V at -10 C (597.7 V string) and 51.28 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,306 W PTC; NEC 690.8 OCPD floor is 14.26 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.65 * (1 + (-0.33/100) * (-10 - 25)) = 49.81 V | OCPD = 1.56 * 9.14 = 14.26 A
Inputs from CEC Modules.csv for PEIMAR SG310P: Voc=44.65 V, beta_Voc=-0.33%/C, Isc=9.14 A, STC=310.0 W, Area=1.94 m2.
Result: 12 panels max on 600 V (597.7 V); 26 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for PEIMAR SG310P?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SG310P. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 281.0 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.65 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.3 V / 8.54 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.98% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many PEIMAR SG310P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SG310P (310.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 418 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 543 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 689 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?
All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SG310P architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PEIMAR SG300P | 300.0 W | 268.3 W | 43.4 V | 36.2 V | 15.46% |
| PEIMAR SG305P | 305.0 W | 276.4 W | 44.53 V | 36.2 V | 15.72% |
| PEIMAR SG310P | 310.0 W | 281.0 W | 44.65 V | 36.3 V | 15.98% |
| PEIMAR SG315P | 315.0 W | 285.7 W | 44.77 V | 36.4 V | 16.23% |
| PEIMAR SG320P | 320.0 W | 290.3 W | 45.75 V | 37.5 V | 16.49% |
How Many PEIMAR SG310P Modules Fit in a Cold-Weather String?
Maximum series module counts for PEIMAR SG310P from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.28 V | 11 panels | 564.1 V | 19 panels |
| -10 C (14 F) | 49.81 V | 12 panels | 597.7 V | 20 panels |
| 0 C (32 F) | 48.33 V | 12 panels | 580.0 V | 20 panels |
| 25 C (77 F STC) | 44.65 V | 13 panels | 580.4 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG310P?
Alternative CEC solar modules from competing brands near PEIMAR SG310P (310.0 W), including Anhui Rinengzhongtian Semiconductor Development QJM310-72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJM310-72 Anhui Rinengzhongtian Semiconductor Development |
310.0 W | Tie (0 W) | 44.65 V | 15.98% | 90.0% |
| Anhui Rinengzhongtian Semiconductor Development QJP310-72 Anhui Rinengzhongtian Semiconductor Development |
310.0 W | Tie (0 W) | 44.65 V | 15.98% | 90.6% |
| CSI Solar Co Ltd CS6X-310P CSI Solar Co Ltd |
310.0 W | Tie (0 W) | 44.9 V | 16.31% | 91.4% |
| Auxin Solar AXN6M612T310 Auxin Solar |
310.0 W | Tie (0 W) | 45.0 V | 15.89% | 89.4% |
What Are the Design Limits and Best-Fit Uses for PEIMAR SG310P?
Evaluate PEIMAR SG310P (310.0 W STC, 44.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG310P reaches 51.28 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of PEIMAR SG310P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR SG310P 8 kW Residential Fit
Needs 26 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM310-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR SG310P by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What fuse or breaker size does NEC 690.8 require for PEIMAR SG310P?
Multiplying PEIMAR SG310P's 9.14 A short-circuit current by 1.56 equals 14.26 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SG310P before finalizing component orders.
Can PEIMAR SG310P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.81 V cold Voc at 14 F and handles 9.14 A Isc; string inverters cap PEIMAR SG310P at 12 panels on 600 V.
Is PEIMAR SG310P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SG310P rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)