Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SG310M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG310M is a 310.0 W STC (280.5 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.02% efficiency, 40.81 V Voc at 25 C, and 45.65 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
280.5 W
Voc @ 25C
40.81 V
Efficiency
19.02%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG310M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PEIMAR SG310M (Mono-c-Si) residential solar systems. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

PEIMAR SG310M delivers 190.2 W/m2 (0.89 percentage points below 19.91% CEC median) and typical 90.5% PTC-to-STC thermal output (280.5 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (456 sq ft). At -4 F (-20 C), string voltage climbs to 47.04 V per unit, capping 600 V circuits at 12 panels. Compare specs directly with Auxin Solar AXN6M610T310 (310.0 W).

Where Does PEIMAR SG310M Fall Across Listed CEC Models?

Comparison of PEIMAR SG310M (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG310M (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG310M: 310.0 W

What Dataset Percentiles Define PEIMAR SG310M?

Relative ranking of PEIMAR SG310M across nameplate watts, 90.5% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

PEIMAR SG310M Engineering BenchmarksPercentile comparison of PEIMAR SG310M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention90.5%Module Efficiency19.02%

What Do the Dataset Ranks Show for PEIMAR SG310M?

Summary of PEIMAR SG310M output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,390

19.02% Aperture Efficiency

Power density 190.2 W/m2 (0.89 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.65 V at -10 C (593.4 V string) and 47.04 V at -20 C (12 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 42.4 m2 (456 sq ft) producing 7,293 W PTC; NEC 690.8 OCPD floor is 15.48 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.81 * (1 + (-0.339/100) * (-10 - 25)) = 45.65 V | OCPD = 1.56 * 9.92 = 15.48 A

Inputs from CEC Modules.csv for PEIMAR SG310M: Voc=40.81 V, beta_Voc=-0.339%/C, Isc=9.92 A, STC=310.0 W, Area=1.63 m2.

Result: 13 panels max on 600 V (593.4 V); 26 panels for 8 kW (456 sq ft).

What Are the Published CEC Specifications for PEIMAR SG310M?

Complete CEC test sheet for PEIMAR SG310M including Isc (9.92 A), Voc (40.81 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG310M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 280.5 W (90.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.81 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.92 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.45 V / 9.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.339 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.02% (1.63 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SG310M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PEIMAR SG310M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 351 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 456 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 579 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Related PEIMAR power steps and black/silver trims consolidated into this PEIMAR SG310M series guide. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the PEIMAR SG310M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG300M 300.0 W 271.2 W 40.33 V 33.05 V 18.4%
PEIMAR SG305M 305.0 W 275.8 W 40.57 V 33.25 V 18.71%
PEIMAR SG310M 310.0 W 280.5 W 40.81 V 33.45 V 19.02%
PEIMAR SG315M 315.0 W 285.2 W 41.18 V 33.75 V 19.33%

How Many PEIMAR SG310M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PEIMAR SG310M (40.81 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=40.81V and beta_Voc=-0.339%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.04 V 12 panels 564.5 V 21 panels
-10 C (14 F) 45.65 V 13 panels 593.4 V 21 panels
0 C (32 F) 44.27 V 13 panels 575.5 V 22 panels
25 C (77 F STC) 40.81 V 14 panels 571.3 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG310M?

Four comparable CEC modules such as Auxin Solar AXN6M610T310 (310.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M610T310
Auxin Solar
310.0 W Tie (0 W) 41.14 V 19.05% 91.8%
CertainTeed CT310M11-02
CertainTeed
310.0 W Tie (0 W) 41.14 V 19.68% 91.4%
DualSun SAS DualSun 310M-60-00
DualSun SAS
310.0 W Tie (0 W) 40.3 V 18.9% 91.4%
Bluesun Solar Energy Tech CoLtd BSM310M-60
Bluesun Solar Energy Tech CoLtd
310.0 W Tie (0 W) 40.18 V 19.02% 91.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG310M?

Evaluate PEIMAR SG310M (310.0 W STC, 40.81 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG310M reaches 47.04 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 456 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (456 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG310M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG310M 8 kW Residential Fit

Needs 26 modules (456 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Auxin Solar AXN6M610T310.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 280.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG310M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

How many PEIMAR SG310M panels fit on a 600 V winter solar string?

At -10 C (14 F), PEIMAR SG310M cold Voc rises from 40.81 V to 45.65 V (beta_Voc -0.339%/C), capping a 600 V string at 13 panels (593.4 V).

How much roof area does an 8 kW array of PEIMAR SG310M need?

An 8 kW DC system uses 26 PEIMAR SG310M modules (8,060 W STC / 7,293 W PTC), covering roughly 456 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does PEIMAR SG310M compare against Auxin Solar AXN6M610T310?

PEIMAR SG310M outputs 310.0 W STC (40.81 V Voc, rank #15,760 of 21,677), while Auxin Solar AXN6M610T310 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.