PEIMAR SG285P is a 285.0 W STC (255.9 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 17.48% efficiency, 39.02 V Voc at 25 C, and 43.95 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 255.9 W
- Voc @ 25C
- 39.02 V
- Efficiency
- 17.48%
How Does PEIMAR SG285P Compare Against Peer CEC Listings?
Engineering position of PEIMAR SG285P (285.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6610P-285 across 1,407 CEC Multi-c-Si solar modules.
Built with 60 Multi-c-Si cells, PEIMAR SG285P pairs typical 89.8% PTC-to-STC thermal output (255.9 W real-world rating) with 39.02 V nominal Voc. An 8 kW residential build (8,265 W DC, 7,421 W PTC) saves ~$2,070/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6610P-285 offers a 285.0 W alternative.
Where Does PEIMAR SG285P Fall Across Listed CEC Models?
Plots PEIMAR SG285P at 285.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define PEIMAR SG285P?
Benchmarks PEIMAR SG285P on STC wattage, thermal PTC/STC retention, and 17.48 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for PEIMAR SG285P?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR SG285P by PEIMAR.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
17.48% Aperture Efficiency
Power density 174.8 W/m2 (2.43 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.95 V at -10 C (571.4 V string) and 45.36 V at -20 C (13 max).
29 Panels = 8,265 W STC
Occupies 47.3 m2 (509 sq ft) producing 7,421 W PTC; NEC 690.8 OCPD floor is 14.9 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.02 * (1 + (-0.361/100) * (-10 - 25)) = 43.95 V | OCPD = 1.56 * 9.55 = 14.9 A
Inputs from CEC Modules.csv for PEIMAR SG285P: Voc=39.02 V, beta_Voc=-0.361%/C, Isc=9.55 A, STC=285.0 W, Area=1.63 m2.
Result: 13 panels max on 600 V (571.4 V); 29 panels for 8 kW (509 sq ft).
What Are the Published CEC Specifications for PEIMAR SG285P?
Laboratory test ratings recorded for PEIMAR SG285P (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 255.9 W (89.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.02 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.98 V / 8.92 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.361 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.48% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many PEIMAR SG285P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (509 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR SG285P.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 386 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 509 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 632 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?
Sibling wattage bins and frame colors grouped with PEIMAR SG285P under PEIMAR to prevent duplicate spec pages. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PEIMAR SG275P | 275.0 W | 249.7 W | 38.53 V | 31.58 V | 16.87% |
| PEIMAR SG280P | 280.0 W | 251.3 W | 38.78 V | 31.78 V | 17.18% |
| PEIMAR SG285P | 285.0 W | 255.9 W | 39.02 V | 31.98 V | 17.48% |
| PEIMAR SG290P | 290.0 W | 260.6 W | 39.28 V | 32.2 V | 17.79% |
How Many PEIMAR SG285P Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for PEIMAR SG285P (beta_Voc -0.361%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.36 V | 13 panels | 589.7 V | 22 panels |
| -10 C (14 F) | 43.95 V | 13 panels | 571.4 V | 22 panels |
| 0 C (32 F) | 42.54 V | 14 panels | 595.6 V | 23 panels |
| 25 C (77 F STC) | 39.02 V | 15 panels | 585.3 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG285P?
Closest cross-brand CEC competitors to PEIMAR SG285P matched near 285.0 W STC and 39.02 V Voc, led by Boviet Solar Technology Co Ltd BVM6610P-285.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6610P-285 Boviet Solar Technology Co Ltd |
285.0 W | Tie (0 W) | 39.0 V | 17.52% | 92.5% |
| AXITEC AC-285M/156-60S AXITEC |
285.0 W | Tie (0 W) | 38.9 V | 17.52% | 91.5% |
| Boviet Solar Technology Co Ltd BVM6610M-285 Boviet Solar Technology Co Ltd |
285.0 W | Tie (0 W) | 38.9 V | 17.52% | 92.0% |
| GCL System Integration Technology Co Ltd GCL-M6/60285 GCL System Integration Technology Co Ltd |
285.0 W | Tie (0 W) | 38.9 V | 17.48% | 90.1% |
What Are the Design Limits and Best-Fit Uses for PEIMAR SG285P?
Evaluate PEIMAR SG285P (285.0 W STC, 39.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG285P reaches 45.36 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 509 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (509 sq ft).
- 2026 tax credit baseline: cash residential installs of PEIMAR SG285P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR SG285P 8 kW Residential Fit
Needs 29 modules (509 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6610P-285.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 255.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR SG285P by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What fuse or breaker size does NEC 690.8 require for PEIMAR SG285P?
Multiplying PEIMAR SG285P's 9.55 A short-circuit current by 1.56 equals 14.9 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SG285P before finalizing component orders.
Can PEIMAR SG285P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.95 V cold Voc at 14 F and handles 9.55 A Isc; string inverters cap PEIMAR SG285P at 13 panels on 600 V.
Is PEIMAR SG285P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SG285P rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)