PEIMAR SG285P is a 285.0 W STC (255.9 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 17.48% efficiency, 39.02 V Voc at 25 C, and 43.95 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
255.9 W
Voc @ 25C
39.02 V
Efficiency
17.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG285P Compare Against Peer CEC Listings?

Engineering position of PEIMAR SG285P (285.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6610P-285 across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, PEIMAR SG285P pairs typical 89.8% PTC-to-STC thermal output (255.9 W real-world rating) with 39.02 V nominal Voc. An 8 kW residential build (8,265 W DC, 7,421 W PTC) saves ~$2,070/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6610P-285 offers a 285.0 W alternative.

Where Does PEIMAR SG285P Fall Across Listed CEC Models?

Plots PEIMAR SG285P at 285.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG285P (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG285P: 285.0 W

What Dataset Percentiles Define PEIMAR SG285P?

Benchmarks PEIMAR SG285P on STC wattage, thermal PTC/STC retention, and 17.48 aperture conversion efficiency against CEC peers.

PEIMAR SG285P Engineering BenchmarksPercentile comparison of PEIMAR SG285P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention89.8%Module Efficiency17.48%

What Do the Dataset Ranks Show for PEIMAR SG285P?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR SG285P by PEIMAR.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,803

17.48% Aperture Efficiency

Power density 174.8 W/m2 (2.43 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.95 V at -10 C (571.4 V string) and 45.36 V at -20 C (13 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 47.3 m2 (509 sq ft) producing 7,421 W PTC; NEC 690.8 OCPD floor is 14.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.02 * (1 + (-0.361/100) * (-10 - 25)) = 43.95 V | OCPD = 1.56 * 9.55 = 14.9 A

Inputs from CEC Modules.csv for PEIMAR SG285P: Voc=39.02 V, beta_Voc=-0.361%/C, Isc=9.55 A, STC=285.0 W, Area=1.63 m2.

Result: 13 panels max on 600 V (571.4 V); 29 panels for 8 kW (509 sq ft).

What Are the Published CEC Specifications for PEIMAR SG285P?

Laboratory test ratings recorded for PEIMAR SG285P (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG285P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 255.9 W (89.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.02 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.98 V / 8.92 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.361 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.48% (1.63 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many PEIMAR SG285P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (509 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR SG285P.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 386 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 509 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 632 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Sibling wattage bins and frame colors grouped with PEIMAR SG285P under PEIMAR to prevent duplicate spec pages. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the PEIMAR SG285P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG275P 275.0 W 249.7 W 38.53 V 31.58 V 16.87%
PEIMAR SG280P 280.0 W 251.3 W 38.78 V 31.78 V 17.18%
PEIMAR SG285P 285.0 W 255.9 W 39.02 V 31.98 V 17.48%
PEIMAR SG290P 290.0 W 260.6 W 39.28 V 32.2 V 17.79%

How Many PEIMAR SG285P Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PEIMAR SG285P (beta_Voc -0.361%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=39.02V and beta_Voc=-0.361%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.36 V 13 panels 589.7 V 22 panels
-10 C (14 F) 43.95 V 13 panels 571.4 V 22 panels
0 C (32 F) 42.54 V 14 panels 595.6 V 23 panels
25 C (77 F STC) 39.02 V 15 panels 585.3 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG285P?

Closest cross-brand CEC competitors to PEIMAR SG285P matched near 285.0 W STC and 39.02 V Voc, led by Boviet Solar Technology Co Ltd BVM6610P-285.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6610P-285
Boviet Solar Technology Co Ltd
285.0 W Tie (0 W) 39.0 V 17.52% 92.5%
AXITEC AC-285M/156-60S
AXITEC
285.0 W Tie (0 W) 38.9 V 17.52% 91.5%
Boviet Solar Technology Co Ltd BVM6610M-285
Boviet Solar Technology Co Ltd
285.0 W Tie (0 W) 38.9 V 17.52% 92.0%
GCL System Integration Technology Co Ltd GCL-M6/60285
GCL System Integration Technology Co Ltd
285.0 W Tie (0 W) 38.9 V 17.48% 90.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG285P?

Evaluate PEIMAR SG285P (285.0 W STC, 39.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG285P reaches 45.36 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 509 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (509 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG285P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG285P 8 kW Residential Fit

Needs 29 modules (509 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6610P-285.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 255.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG285P by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

What fuse or breaker size does NEC 690.8 require for PEIMAR SG285P?

Multiplying PEIMAR SG285P's 9.55 A short-circuit current by 1.56 equals 14.9 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SG285P before finalizing component orders.

Can PEIMAR SG285P pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.95 V cold Voc at 14 F and handles 9.55 A Isc; string inverters cap PEIMAR SG285P at 13 panels on 600 V.

Is PEIMAR SG285P eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SG285P rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.