Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-285M/156-60S is a 285.0 W STC (260.7 W PTC) Mono-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 17.52% efficiency, 38.9 V Voc at 25 C, and 43.15 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
260.7 W
Voc @ 25C
38.9 V
Efficiency
17.52%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-285M/156-60S Compare Against Peer CEC Listings?

Solar engineering breakdown for AXITEC AC-285M/156-60S: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Across 5,889 Mono-c-Si listings from AXITEC and peers, AXITEC AC-285M/156-60S stands 125.0 W below the 410.0 W Mono-c-Si median and strong 91.5% PTC-to-STC heat retention (#15,584 of 21,677). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,569-$2,568/yr in baseline US bill offset. Lower 38.9 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does AXITEC AC-285M/156-60S Fall Across Listed CEC Models?

Distribution marker showing AXITEC AC-285M/156-60S (285.0 W) relative to the 385.0 W all-CEC solar panel median. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-285M/156-60S (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-285M/156: 285.0 W

What Dataset Percentiles Define AXITEC AC-285M/156-60S?

Dataset percentiles tracking AXITEC AC-285M/156-60S power output, thermal retention ratio, and aperture efficiency against 21,677 models. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

AXITEC AC-285M/156-60S Engineering BenchmarksPercentile comparison of AXITEC AC-285M/156-60S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention91.5%Module Efficiency17.52%

What Do the Dataset Ranks Show for AXITEC AC-285M/156-60S?

Benchmark highlights for AXITEC AC-285M/156-60S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,748

17.52% Aperture Efficiency

Power density 175.2 W/m2 (2.39 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.15 V at -10 C (560.9 V string) and 44.36 V at -20 C (13 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 47.2 m2 (508 sq ft) producing 7,560 W PTC; NEC 690.8 OCPD floor is 14.91 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.9 * (1 + (-0.312/100) * (-10 - 25)) = 43.15 V | OCPD = 1.56 * 9.56 = 14.91 A

Inputs from CEC Modules.csv for AXITEC AC-285M/156-60S: Voc=38.9 V, beta_Voc=-0.312%/C, Isc=9.56 A, STC=285.0 W, Area=1.627 m2.

Result: 13 panels max on 600 V (560.9 V); 29 panels for 8 kW (508 sq ft).

What Are the Published CEC Specifications for AXITEC AC-285M/156-60S?

Official CEC datasheet figures for AXITEC AC-285M/156-60S (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-285M/156-60S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 260.7 W (91.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.56 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.5 V / 9.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.312 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.52% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many AXITEC AC-285M/156-60S Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many AXITEC AC-285M/156-60S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 385 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 508 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 630 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Consolidated AXITEC wattage variants sharing the AXITEC AC-285M/156-60S mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the AXITEC AC-285M/156-60S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-280M/156-60S 280.0 W 250.7 W 39.1 V 31.43 V 17.21%
AXITEC AC-285M/156-60S 285.0 W 260.7 W 38.9 V 31.5 V 17.52%
AXITEC AC-290M/156-60S 290.0 W 265.4 W 39.2 V 31.8 V 17.83%

How Many AXITEC AC-285M/156-60S Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-285M/156-60S (43.15 V at 14 F).

Computed from Voc=38.9V and beta_Voc=-0.312%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.36 V 13 panels 576.7 V 22 panels
-10 C (14 F) 43.15 V 13 panels 560.9 V 23 panels
0 C (32 F) 41.93 V 14 panels 587.0 V 23 panels
25 C (77 F STC) 38.9 V 15 panels 583.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-285M/156-60S?

Competing CEC solar panels closest to AXITEC AC-285M/156-60S in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6610M-285.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6610M-285
Boviet Solar Technology Co Ltd
285.0 W Tie (0 W) 38.9 V 17.52% 92.0%
GCL System Integration Technology Co Ltd GCL-M6/60285
GCL System Integration Technology Co Ltd
285.0 W Tie (0 W) 38.9 V 17.48% 90.1%
GCL System Integration Technology Co Ltd GCL-P6/60285
GCL System Integration Technology Co Ltd
285.0 W Tie (0 W) 38.9 V 17.48% 90.7%
Boviet Solar Technology Co Ltd BVM6610P-285
Boviet Solar Technology Co Ltd
285.0 W Tie (0 W) 39.0 V 17.52% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-285M/156-60S?

Evaluate AXITEC AC-285M/156-60S (285.0 W STC, 38.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-285M/156-60S reaches 44.36 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 508 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (508 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-285M/156-60S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-285M/156-60S 8 kW Residential Fit

Needs 29 modules (508 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6610M-285.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 260.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-285M/156-60S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for AXITEC AC-285M/156-60S?

Multiplying AXITEC AC-285M/156-60S's 9.56 A short-circuit current by 1.56 equals 14.91 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can AXITEC AC-285M/156-60S pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.15 V cold Voc at 14 F and handles 9.56 A Isc; string inverters cap AXITEC AC-285M/156-60S at 13 panels on 600 V.

Is AXITEC AC-285M/156-60S eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-285M/156-60S rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.