Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SG235M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG235M is a 235.0 W STC (211.4 W PTC) Mono-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.44% efficiency, 36.65 V Voc at 25 C, and 40.84 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
211.4 W
Voc @ 25C
36.65 V
Efficiency
14.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG235M Compare Against Peer CEC Listings?

Engineering position of PEIMAR SG235M (235.0 W STC) vs. Anhui Rinengzhongtian Semiconductor Development QJM235-60 across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, PEIMAR SG235M pairs typical 90.0% PTC-to-STC thermal output (211.4 W real-world rating) with 36.65 V nominal Voc. An 8 kW residential build (8,225 W DC, 7,399 W PTC) saves ~$2,057/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Anhui Rinengzhongtian Semiconductor Development QJM235-60 offers a 235.0 W alternative.

Where Does PEIMAR SG235M Fall Across Listed CEC Models?

Plots PEIMAR SG235M at 235.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG235M (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG235M: 235.0 W

What Dataset Percentiles Define PEIMAR SG235M?

Benchmarks PEIMAR SG235M on STC wattage, thermal PTC/STC retention, and 14.44 aperture conversion efficiency against CEC peers.

PEIMAR SG235M Engineering BenchmarksPercentile comparison of PEIMAR SG235M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention90.0%Module Efficiency14.44%

What Do the Dataset Ranks Show for PEIMAR SG235M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR SG235M by PEIMAR.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,465

14.44% Aperture Efficiency

Power density 144.4 W/m2 (5.47 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.84 V at -10 C (571.8 V string) and 42.04 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 56.9 m2 (613 sq ft) producing 7,399 W PTC; NEC 690.8 OCPD floor is 13.17 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.65 * (1 + (-0.327/100) * (-10 - 25)) = 40.84 V | OCPD = 1.56 * 8.44 = 13.17 A

Inputs from CEC Modules.csv for PEIMAR SG235M: Voc=36.65 V, beta_Voc=-0.327%/C, Isc=8.44 A, STC=235.0 W, Area=1.627 m2.

Result: 14 panels max on 600 V (571.8 V); 35 panels for 8 kW (613 sq ft).

What Are the Published CEC Specifications for PEIMAR SG235M?

Laboratory test ratings recorded for PEIMAR SG235M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG235M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 211.4 W (90.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.65 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.44 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.8 V / 7.89 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.327 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.44% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SG235M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (613 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR SG235M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 455 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 613 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 753 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Sibling wattage bins and frame colors grouped with PEIMAR SG235M under PEIMAR to prevent duplicate spec pages. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the PEIMAR SG235M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG225M 225.0 W 202.2 W 36.41 V 29.6 V 13.83%
PEIMAR SG230M 230.0 W 206.8 W 36.53 V 29.7 V 14.14%
PEIMAR SG235M 235.0 W 211.4 W 36.65 V 29.8 V 14.44%
PEIMAR SG240M 240.0 W 216.0 W 36.78 V 29.9 V 14.75%
PEIMAR SG245M 245.0 W 220.6 W 37.02 V 30.1 V 15.06%

How Many PEIMAR SG235M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PEIMAR SG235M (beta_Voc -0.327%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.65V and beta_Voc=-0.327%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.04 V 14 panels 588.6 V 23 panels
-10 C (14 F) 40.84 V 14 panels 571.8 V 24 panels
0 C (32 F) 39.65 V 15 panels 594.8 V 25 panels
25 C (77 F STC) 36.65 V 16 panels 586.4 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG235M?

Closest cross-brand CEC competitors to PEIMAR SG235M matched near 235.0 W STC and 36.65 V Voc, led by Anhui Rinengzhongtian Semiconductor Development QJM235-60.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJM235-60
Anhui Rinengzhongtian Semiconductor Development
235.0 W Tie (0 W) 36.65 V 14.44% 90.0%
Advance Power API-P235
Advance Power
235.0 W Tie (0 W) 36.72 V 14.35% 89.2%
Alps Technology ATI-M660-235
Alps Technology
235.0 W Tie (0 W) 36.72 V 14.6% 86.2%
Anji Technology AJP-M660-235
Anji Technology
235.0 W Tie (0 W) 36.72 V 14.47% 88.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG235M?

Evaluate PEIMAR SG235M (235.0 W STC, 36.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG235M reaches 42.04 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 613 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (613 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG235M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG235M 8 kW Residential Fit

Needs 35 modules (613 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM235-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 211.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG235M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

What fuse or breaker size does NEC 690.8 require for PEIMAR SG235M?

Multiplying PEIMAR SG235M's 8.44 A short-circuit current by 1.56 equals 13.17 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SG235M before finalizing component orders.

Can PEIMAR SG235M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.84 V cold Voc at 14 F and handles 8.44 A Isc; string inverters cap PEIMAR SG235M at 14 panels on 600 V.

Is PEIMAR SG235M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SG235M rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.