Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SG185M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG185M is a 185.0 W STC (164.2 W PTC) Mono-c-Si solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 14.49% efficiency, 43.4 V Voc at 25 C, and 48.97 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
185.0 W
PTC Wattage
164.2 W
Voc @ 25C
43.4 V
Efficiency
14.49%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG185M Compare Against Peer CEC Listings?

Engineering position of PEIMAR SG185M (185.0 W STC) vs. Anhui Rinengzhongtian Semiconductor Development QJM185-72 across 5,889 CEC Mono-c-Si solar modules.

Ranking #21,185 across 21,677 CEC solar panels (below all-CEC median; higher than 2.1% of peers), PEIMAR SG185M operates as a compact residential or specialty off-grid module sitting 225.0 W below the 410.0 W Mono-c-Si median. Mid-range 43.4 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F. With typical 88.8% PTC-to-STC thermal output (164.2 W real-world rating), 44 panels occupy 605 sq ft and offset roughly $2,037/yr at average US rates (or $3,445/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PEIMAR SG185M Fall Across Listed CEC Models?

Plots PEIMAR SG185M at 185.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG185M (185.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG185M: 185.0 W

What Dataset Percentiles Define PEIMAR SG185M?

Benchmarks PEIMAR SG185M on STC wattage, thermal PTC/STC retention, and 14.49 aperture conversion efficiency against CEC peers.

PEIMAR SG185M Engineering BenchmarksPercentile comparison of PEIMAR SG185M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage185.0 WPTC/STC Retention88.8%Module Efficiency14.49%

What Do the Dataset Ranks Show for PEIMAR SG185M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR SG185M by PEIMAR.

Rank #21,185 / 21,677

185.0 W STC · Higher Than 2.1%

185.0 W STC (-200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,423

14.49% Aperture Efficiency

Power density 144.9 W/m2 (5.42 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.97 V at -10 C (587.6 V string) and 50.57 V at -20 C (11 max).

8 kW Reference Array

44 Panels = 8,140 W STC

Occupies 56.2 m2 (605 sq ft) producing 7,225 W PTC; NEC 690.8 OCPD floor is 8.92 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.4 * (1 + (-0.367/100) * (-10 - 25)) = 48.97 V | OCPD = 1.56 * 5.72 = 8.92 A

Inputs from CEC Modules.csv for PEIMAR SG185M: Voc=43.4 V, beta_Voc=-0.367%/C, Isc=5.72 A, STC=185.0 W, Area=1.277 m2.

Result: 12 panels max on 600 V (587.6 V); 44 panels for 8 kW (605 sq ft).

What Are the Published CEC Specifications for PEIMAR SG185M?

Laboratory test ratings recorded for PEIMAR SG185M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG185M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 185.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 164.2 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.72 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.2 V / 5.11 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.367 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.49% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SG185M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (605 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR SG185M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 33 6.11 kW 454 sq ft $1,529 $2,586
8 kW Class 44 8.14 kW 605 sq ft $2,037 $3,445
10 kW Class 55 10.18 kW 756 sq ft $2,548 $4,308

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Sibling wattage bins and frame colors grouped with PEIMAR SG185M under PEIMAR to prevent duplicate spec pages. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the PEIMAR SG185M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG175M 175.0 W 155.1 W 43.1 V 35.9 V 13.71%
PEIMAR SG180M 180.0 W 159.6 W 43.3 V 36.1 V 14.1%
PEIMAR SG185M 185.0 W 164.2 W 43.4 V 36.2 V 14.49%
PEIMAR SG190M 190.0 W 168.8 W 43.5 V 36.3 V 14.88%
PEIMAR SG195M 195.0 W 173.4 W 43.6 V 36.3 V 15.27%

How Many PEIMAR SG185M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PEIMAR SG185M (beta_Voc -0.367%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=43.4V and beta_Voc=-0.367%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.57 V 11 panels 556.3 V 19 panels
-10 C (14 F) 48.97 V 12 panels 587.6 V 20 panels
0 C (32 F) 47.38 V 12 panels 568.6 V 21 panels
25 C (77 F STC) 43.4 V 13 panels 564.2 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG185M?

Closest cross-brand CEC competitors to PEIMAR SG185M matched near 185.0 W STC and 43.4 V Voc, led by Anhui Rinengzhongtian Semiconductor Development QJM185-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJM185-72
Anhui Rinengzhongtian Semiconductor Development
185.0 W Tie (0 W) 43.4 V 14.49% 88.8%
Philadelphia Solar PS-M72S-185
Philadelphia Solar
185.0 W Tie (0 W) 43.8 V 14.45% 88.5%
Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-185
Jinzhou Jinmao Photovoltaic Technology
185.0 W Tie (0 W) 44.47 V 14.49% 86.6%
Juli New Energy JLS180M
Juli New Energy
180.0 W -5.0 W 43.2 V 14.1% 87.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG185M?

Evaluate PEIMAR SG185M (185.0 W STC, 43.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG185M reaches 50.57 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 44 panels for an 8 kW build require 605 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (605 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG185M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG185M 8 kW Residential Fit

Needs 44 modules (605 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM185-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 164.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG185M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

How many PEIMAR SG185M panels fit on a 600 V winter solar string?

At -10 C (14 F), PEIMAR SG185M cold Voc rises from 43.4 V to 48.97 V (beta_Voc -0.367%/C), capping a 600 V string at 12 panels (587.6 V).

How much roof area does an 8 kW array of PEIMAR SG185M need?

An 8 kW DC system uses 44 PEIMAR SG185M modules (8,140 W STC / 7,225 W PTC), covering roughly 605 sq ft and saving ~$2,037/yr at 18.54 c/kWh.

How does PEIMAR SG185M compare against Anhui Rinengzhongtian Semiconductor Development QJM185-72?

PEIMAR SG185M outputs 185.0 W STC (43.4 V Voc, rank #21,185 of 21,677), while Anhui Rinengzhongtian Semiconductor Development QJM185-72 delivers 185.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.