Juli New Energy JLS180M — CEC Solar Module Specifications

Manufacturer: Juli New Energy Registry: CEC Verified Engineering Specification

Juli New Energy JLS180M is a 180.0 W STC (157.6 W PTC) Mono-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 14.1% efficiency, 43.2 V Voc at 25 C, and 49.14 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
180.0 W
PTC Wattage
157.6 W
Voc @ 25C
43.2 V
Efficiency
14.1%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Juli New Energy JLS180M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Juli New Energy JLS180M (Mono-c-Si) residential solar systems.

Juli New Energy JLS180M delivers 141.0 W/m2 (5.81 percentage points below 19.91% CEC median) and typical 87.6% PTC-to-STC thermal output (157.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (619 sq ft). At -4 F (-20 C), string voltage climbs to 50.84 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Alps Technology ATI-S572-180 (180.0 W).

Where Does Juli New Energy JLS180M Fall Across Listed CEC Models?

Comparison of Juli New Energy JLS180M (180.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Juli New Energy JLS180M (180.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJuli New Energy JL: 180.0 W

What Dataset Percentiles Define Juli New Energy JLS180M?

Relative ranking of Juli New Energy JLS180M across nameplate watts, 87.6% PTC thermal ratio, and module aperture efficiency.

Juli New Energy JLS180M Engineering BenchmarksPercentile comparison of Juli New Energy JLS180M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage180.0 WPTC/STC Retention87.6%Module Efficiency14.1%

What Do the Dataset Ranks Show for Juli New Energy JLS180M?

Summary of Juli New Energy JLS180M output rank, 8 kW array size (45 panels), efficiency rating, and 600 V string limit.

Rank #21,232 / 21,677

180.0 W STC · Higher Than 1.8%

180.0 W STC (-205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,802

14.1% Aperture Efficiency

Power density 141.0 W/m2 (5.81 percentage points below 19.91% CEC median). PTC/STC ratio: 87.6% (rank #21,526).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.14 V at -10 C (589.7 V string) and 50.84 V at -20 C (11 max).

8 kW Reference Array

45 Panels = 8,100 W STC

Occupies 57.5 m2 (619 sq ft) producing 7,092 W PTC; NEC 690.8 OCPD floor is 8.74 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.2 * (1 + (-0.393/100) * (-10 - 25)) = 49.14 V | OCPD = 1.56 * 5.6 = 8.74 A

Inputs from CEC Modules.csv for Juli New Energy JLS180M: Voc=43.2 V, beta_Voc=-0.393%/C, Isc=5.6 A, STC=180.0 W, Area=1.277 m2.

Result: 12 panels max on 600 V (589.7 V); 45 panels for 8 kW (619 sq ft).

What Are the Published CEC Specifications for Juli New Energy JLS180M?

Complete CEC test sheet for Juli New Energy JLS180M including Isc (5.6 A), Voc (43.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Juli New Energy JLS180M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 180.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 157.6 W (87.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.0 V / 5.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.393 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.1% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Juli New Energy JLS180M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Juli New Energy JLS180M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 34 6.12 kW 467 sq ft $1,532 $2,590
8 kW Class 45 8.1 kW 619 sq ft $2,027 $3,428
10 kW Class 56 10.08 kW 770 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Juli New Energy Series?

Related Juli New Energy power steps and black/silver trims consolidated into this Juli New Energy JLS180M series guide.

Sibling CEC listings grouped into the Juli New Energy JLS180M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Juli New Energy JLS175M 175.0 W 153.1 W 42.6 V 35.5 V 13.71%
Juli New Energy JLS180M 180.0 W 157.6 W 43.2 V 36.0 V 14.1%

How Many Juli New Energy JLS180M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Juli New Energy JLS180M (43.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=43.2V and beta_Voc=-0.393%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.84 V 11 panels 559.2 V 19 panels
-10 C (14 F) 49.14 V 12 panels 589.7 V 20 panels
0 C (32 F) 47.44 V 12 panels 569.3 V 21 panels
25 C (77 F STC) 43.2 V 13 panels 561.6 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Juli New Energy JLS180M?

Four comparable CEC modules such as Alps Technology ATI-S572-180 (180.0 W) for side-by-side solar quote checks. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Alps Technology ATI-S572-180
Alps Technology
180.0 W Tie (0 W) 44.06 V 13.98% 86.5%
Anji Technology AJP-S572-180
Anji Technology
180.0 W Tie (0 W) 44.06 V 13.84% 86.5%
Guangdong Golden Glass Technologies GG180S1-36/1589x807
Guangdong Golden Glass Technologies
180.0 W Tie (0 W) 44.2 V 14.04% 90.8%
Trina Solar TSM-180DA01
Trina Solar
180.0 W Tie (0 W) 44.2 V 14.26% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Juli New Energy JLS180M?

Evaluate Juli New Energy JLS180M (180.0 W STC, 43.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Juli New Energy JLS180M reaches 50.84 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 45 panels for an 8 kW build require 619 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (619 sq ft).
  • 2026 tax credit baseline: cash residential installs of Juli New Energy JLS180M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Juli New Energy JLS180M 8 kW Residential Fit

Needs 45 modules (619 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Alps Technology ATI-S572-180.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 157.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Juli New Energy JLS180M by Juli New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Juli New Energy JLS180M panels fit on a 600 V winter solar string?

At -10 C (14 F), Juli New Energy JLS180M cold Voc rises from 43.2 V to 49.14 V (beta_Voc -0.393%/C), capping a 600 V string at 12 panels (589.7 V).

How much roof area does an 8 kW array of Juli New Energy JLS180M need?

An 8 kW DC system uses 45 Juli New Energy JLS180M modules (8,100 W STC / 7,092 W PTC), covering roughly 619 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Juli New Energy JLS180M compare against Alps Technology ATI-S572-180?

Juli New Energy JLS180M outputs 180.0 W STC (43.2 V Voc, rank #21,232 of 21,677), while Alps Technology ATI-S572-180 delivers 180.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.