Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SF435M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SF435M is a 435.0 W STC (406.8 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.71% efficiency, 50.5 V Voc at 25 C, and 55.2 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
406.8 W
Voc @ 25C
50.5 V
Efficiency
20.71%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SF435M Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SF435M handles rooftop heat (406.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR SF435M exhibits 11.13 A short-circuit current, requiring a 17.36 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #6,850 of 21,677 (25.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.9 m2 for an 8 kW system (23 panels for 10 kW). Higher 50.5 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does PEIMAR SF435M Fall Across Listed CEC Models?

Where PEIMAR SF435M (435.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SF435M (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SF435M: 435.0 W

What Dataset Percentiles Define PEIMAR SF435M?

Percentile placement of PEIMAR SF435M across power density (207.1 W/m2), thermal retention, and nameplate STC wattage. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

PEIMAR SF435M Engineering BenchmarksPercentile comparison of PEIMAR SF435M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention93.5%Module Efficiency20.71%

What Do the Dataset Ranks Show for PEIMAR SF435M?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SF435M specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,667

20.71% Aperture Efficiency

Power density 207.1 W/m2 (0.80 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.2 V at -10 C (552.0 V string) and 56.54 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 39.9 m2 (429 sq ft) producing 7,729 W PTC; NEC 690.8 OCPD floor is 17.36 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.5 * (1 + (-0.266/100) * (-10 - 25)) = 55.2 V | OCPD = 1.56 * 11.13 = 17.36 A

Inputs from CEC Modules.csv for PEIMAR SF435M: Voc=50.5 V, beta_Voc=-0.266%/C, Isc=11.13 A, STC=435.0 W, Area=2.1 m2.

Result: 10 panels max on 600 V (552.0 V); 19 panels for 8 kW (429 sq ft).

What Are the Published CEC Specifications for PEIMAR SF435M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SF435M. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SF435M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 406.8 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.13 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.4 V / 10.51 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.71% (2.1 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SF435M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SF435M (435.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 316 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 429 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 520 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SF435M architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the PEIMAR SF435M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SF425M 425.0 W 397.2 W 49.2 V 41.0 V 20.24%
PEIMAR SF430M 430.0 W 402.0 W 49.4 V 41.2 V 20.48%
PEIMAR SF435M 435.0 W 406.8 W 50.5 V 41.4 V 20.71%
PEIMAR SF440M 440.0 W 411.6 W 50.75 V 41.6 V 20.95%

How Many PEIMAR SF435M Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SF435M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.5V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.54 V 10 panels 565.4 V 17 panels
-10 C (14 F) 55.2 V 10 panels 552.0 V 18 panels
0 C (32 F) 53.86 V 11 panels 592.5 V 18 panels
25 C (77 F STC) 50.5 V 11 panels 555.5 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SF435M?

Alternative CEC solar modules from competing brands near PEIMAR SF435M (435.0 W), including Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
Aptos Solar Technology LLC DNA-144-MF26-435W {Wht}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 92.8%
CertainTeed CT435HC11-06
CertainTeed
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
AXITEC AC-435MH/144V
AXITEC
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SF435M?

Evaluate PEIMAR SF435M (435.0 W STC, 50.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SF435M reaches 56.54 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 429 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (429 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SF435M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SF435M 8 kW Residential Fit

Needs 19 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 406.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SF435M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Why is PEIMAR SF435M PTC wattage (406.8 W) lower than STC (435.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 406.8 W PTC (93.5% retention) across PEIMAR SF435M's 2.1 m2 aperture.

Who should skip PEIMAR SF435M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 PEIMAR SF435M panels (429 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

What is the 1,000 V commercial string limit for PEIMAR SF435M?

On 1,000 V commercial inverters at -10 C (55.2 V cold Voc), PEIMAR SF435M fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SF435M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.