Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SF420M is a 420.0 W STC (392.4 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 20.0% efficiency, 48.96 V Voc at 25 C, and 53.52 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
420.0 W
PTC Wattage
392.4 W
Voc @ 25C
48.96 V
Efficiency
20.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SF420M Compare Against Peer CEC Listings?

Solar engineering breakdown for PEIMAR SF420M: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Across 5,889 Mono-c-Si listings from PEIMAR and peers, PEIMAR SF420M stands 10.0 W above the 410.0 W Mono-c-Si median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (15 panels) to 10 kW (24 panels) yields $1,577-$2,523/yr in baseline US bill offset. Higher 48.96 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does PEIMAR SF420M Fall Across Listed CEC Models?

Distribution marker showing PEIMAR SF420M (420.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SF420M (420.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SF420M: 420.0 W

What Dataset Percentiles Define PEIMAR SF420M?

Dataset percentiles tracking PEIMAR SF420M power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

PEIMAR SF420M Engineering BenchmarksPercentile comparison of PEIMAR SF420M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage420.0 WPTC/STC Retention93.4%Module Efficiency20.0%

What Do the Dataset Ranks Show for PEIMAR SF420M?

Benchmark highlights for PEIMAR SF420M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #7,910 / 21,677

Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,442

20.0% Aperture Efficiency

Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.52 V at -10 C (588.7 V string) and 54.82 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,400 W STC

Occupies 42.0 m2 (452 sq ft) producing 7,848 W PTC; NEC 690.8 OCPD floor is 17.02 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.96 * (1 + (-0.266/100) * (-10 - 25)) = 53.52 V | OCPD = 1.56 * 10.91 = 17.02 A

Inputs from CEC Modules.csv for PEIMAR SF420M: Voc=48.96 V, beta_Voc=-0.266%/C, Isc=10.91 A, STC=420.0 W, Area=2.1 m2.

Result: 11 panels max on 600 V (588.7 V); 20 panels for 8 kW (452 sq ft).

What Are the Published CEC Specifications for PEIMAR SF420M?

Official CEC datasheet figures for PEIMAR SF420M (Mono-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SF420M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 420.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 392.4 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.96 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.91 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.8 V / 10.3 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.0% (2.1 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SF420M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PEIMAR SF420M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.3 kW 339 sq ft $1,577 $2,666
8 kW Class 20 8.4 kW 452 sq ft $2,102 $3,555
10 kW Class 24 10.08 kW 543 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Consolidated PEIMAR wattage variants sharing the PEIMAR SF420M mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the PEIMAR SF420M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SF415M 415.0 W 387.6 W 48.72 V 40.6 V 19.76%
PEIMAR SF420M 420.0 W 392.4 W 48.96 V 40.8 V 20.0%

How Many PEIMAR SF420M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PEIMAR SF420M (53.52 V at 14 F). Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Computed from Voc=48.96V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.82 V 10 panels 548.2 V 18 panels
-10 C (14 F) 53.52 V 11 panels 588.7 V 18 panels
0 C (32 F) 52.22 V 11 panels 574.4 V 19 panels
25 C (77 F STC) 48.96 V 12 panels 587.5 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SF420M?

Competing CEC solar panels closest to PEIMAR SF420M in nameplate wattage and Voc, starting with DualSun SAS DualSun 420M-144-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 420M-144-01
DualSun SAS
420.0 W Tie (0 W) 48.8 V 19.44% 93.8%
AXITEC AC-410MH/144V
AXITEC
410.0 W -10.0 W 48.91 V 20.71% 93.5%
BYD Company Limited BYD400MIK-36
BYD Company Limited
410.0 W -10.0 W 49.21 V 20.4% 94.0%
AXITEC AC-410MB/144V
AXITEC
410.0 W -10.0 W 49.3 V 21.03% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SF420M?

Evaluate PEIMAR SF420M (420.0 W STC, 48.96 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SF420M reaches 54.82 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 452 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (452 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SF420M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SF420M 8 kW Residential Fit

Needs 20 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare DualSun SAS DualSun 420M-144-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 392.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SF420M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

What fuse or breaker size does NEC 690.8 require for PEIMAR SF420M?

Multiplying PEIMAR SF420M's 10.91 A short-circuit current by 1.56 equals 17.02 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SF420M before finalizing component orders.

Can PEIMAR SF420M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.52 V cold Voc at 14 F and handles 10.91 A Isc; string inverters cap PEIMAR SF420M at 11 panels on 600 V.

Is PEIMAR SF420M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SF420M rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.