PEIMAR SF405M is a 405.0 W STC (378.9 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.98% efficiency, 45.84 V Voc at 25 C, and 50.11 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 378.9 W
- Voc @ 25C
- 45.84 V
- Efficiency
- 20.98%
How Does PEIMAR SF405M Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PEIMAR SF405M (Mono-c-Si) residential solar systems. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Homeowners evaluating PEIMAR SF405M need 15 panels for 6 kW or 20 panels (415 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.266%/C) pushes open-circuit voltage to 50.11 V at 14 F and 51.33 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does PEIMAR SF405M Fall Across Listed CEC Models?
Comparison of PEIMAR SF405M (405.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define PEIMAR SF405M?
Relative ranking of PEIMAR SF405M across nameplate watts, 93.6% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for PEIMAR SF405M?
Summary of PEIMAR SF405M output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.98% Aperture Efficiency
Power density 209.8 W/m2 (1.07 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.11 V at -10 C (551.2 V string) and 51.33 V at -20 C (11 max).
20 Panels = 8,100 W STC
Occupies 38.6 m2 (415 sq ft) producing 7,578 W PTC; NEC 690.8 OCPD floor is 17.55 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.84 * (1 + (-0.266/100) * (-10 - 25)) = 50.11 V | OCPD = 1.56 * 11.25 = 17.55 A
Inputs from CEC Modules.csv for PEIMAR SF405M: Voc=45.84 V, beta_Voc=-0.266%/C, Isc=11.25 A, STC=405.0 W, Area=1.93 m2.
Result: 11 panels max on 600 V (551.2 V); 20 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for PEIMAR SF405M?
Complete CEC test sheet for PEIMAR SF405M including Isc (11.25 A), Voc (45.84 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 378.9 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.84 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.25 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.2 V / 10.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.98% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many PEIMAR SF405M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PEIMAR SF405M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 312 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 415 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 519 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?
Related PEIMAR power steps and black/silver trims consolidated into this PEIMAR SF405M series guide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PEIMAR SF400M | 400.0 W | 374.0 W | 45.6 V | 38.0 V | 20.73% |
| PEIMAR SF405M | 405.0 W | 378.9 W | 45.84 V | 38.2 V | 20.98% |
How Many PEIMAR SF405M Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for PEIMAR SF405M (45.84 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.33 V | 11 panels | 564.6 V | 19 panels |
| -10 C (14 F) | 50.11 V | 11 panels | 551.2 V | 19 panels |
| 0 C (32 F) | 48.89 V | 12 panels | 586.7 V | 20 panels |
| 25 C (77 F STC) | 45.84 V | 13 panels | 595.9 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR SF405M?
Four comparable CEC modules such as CSI Solar Co Ltd CS3N-405MS {Wht} (405.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3N-405MS {Wht} CSI Solar Co Ltd |
405.0 W | Tie (0 W) | 44.7 V | 20.56% | 93.5% |
| CSI Solar Co Ltd CS3N-410MS {Blk} CSI Solar Co Ltd |
410.0 W | +5.0 W | 44.9 V | 20.81% | 93.5% |
| Aptos Solar Technology LLC DNA-144-MF23-405W {Blk} Aptos Solar Technology LLC |
405.0 W | Tie (0 W) | 48.73 V | 20.13% | 90.8% |
| Aptos Solar Technology LLC DNA-144-MF23-405W {Wht} Aptos Solar Technology LLC |
405.0 W | Tie (0 W) | 48.73 V | 20.77% | 93.5% |
What Are the Design Limits and Best-Fit Uses for PEIMAR SF405M?
Evaluate PEIMAR SF405M (405.0 W STC, 45.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SF405M reaches 51.33 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PEIMAR SF405M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR SF405M 8 kW Residential Fit
Needs 20 modules (415 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3N-405MS {Wht}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 378.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR SF405M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Why is PEIMAR SF405M PTC wattage (378.9 W) lower than STC (405.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 378.9 W PTC (93.6% retention) across PEIMAR SF405M's 1.93 m2 aperture.
Who should skip PEIMAR SF405M on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 PEIMAR SF405M panels (415 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3N-405MS {Wht}.
What is the 1,000 V commercial string limit for PEIMAR SF405M?
On 1,000 V commercial inverters at -10 C (50.11 V cold Voc), PEIMAR SF405M fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SF405M.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)