Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SF405M is a 405.0 W STC (378.9 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.98% efficiency, 45.84 V Voc at 25 C, and 50.11 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
378.9 W
Voc @ 25C
45.84 V
Efficiency
20.98%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SF405M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PEIMAR SF405M (Mono-c-Si) residential solar systems. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Homeowners evaluating PEIMAR SF405M need 15 panels for 6 kW or 20 panels (415 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.266%/C) pushes open-circuit voltage to 50.11 V at 14 F and 51.33 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PEIMAR SF405M Fall Across Listed CEC Models?

Comparison of PEIMAR SF405M (405.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SF405M (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SF405M: 405.0 W

What Dataset Percentiles Define PEIMAR SF405M?

Relative ranking of PEIMAR SF405M across nameplate watts, 93.6% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

PEIMAR SF405M Engineering BenchmarksPercentile comparison of PEIMAR SF405M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.6%Module Efficiency20.98%

What Do the Dataset Ranks Show for PEIMAR SF405M?

Summary of PEIMAR SF405M output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,510

20.98% Aperture Efficiency

Power density 209.8 W/m2 (1.07 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.11 V at -10 C (551.2 V string) and 51.33 V at -20 C (11 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 38.6 m2 (415 sq ft) producing 7,578 W PTC; NEC 690.8 OCPD floor is 17.55 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.84 * (1 + (-0.266/100) * (-10 - 25)) = 50.11 V | OCPD = 1.56 * 11.25 = 17.55 A

Inputs from CEC Modules.csv for PEIMAR SF405M: Voc=45.84 V, beta_Voc=-0.266%/C, Isc=11.25 A, STC=405.0 W, Area=1.93 m2.

Result: 11 panels max on 600 V (551.2 V); 20 panels for 8 kW (415 sq ft).

What Are the Published CEC Specifications for PEIMAR SF405M?

Complete CEC test sheet for PEIMAR SF405M including Isc (11.25 A), Voc (45.84 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SF405M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 378.9 W (93.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.84 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.25 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.2 V / 10.61 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.98% (1.93 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SF405M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PEIMAR SF405M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 312 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 415 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 519 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Related PEIMAR power steps and black/silver trims consolidated into this PEIMAR SF405M series guide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the PEIMAR SF405M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SF400M 400.0 W 374.0 W 45.6 V 38.0 V 20.73%
PEIMAR SF405M 405.0 W 378.9 W 45.84 V 38.2 V 20.98%

How Many PEIMAR SF405M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PEIMAR SF405M (45.84 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.84V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.33 V 11 panels 564.6 V 19 panels
-10 C (14 F) 50.11 V 11 panels 551.2 V 19 panels
0 C (32 F) 48.89 V 12 panels 586.7 V 20 panels
25 C (77 F STC) 45.84 V 13 panels 595.9 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SF405M?

Four comparable CEC modules such as CSI Solar Co Ltd CS3N-405MS {Wht} (405.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3N-405MS {Wht}
CSI Solar Co Ltd
405.0 W Tie (0 W) 44.7 V 20.56% 93.5%
CSI Solar Co Ltd CS3N-410MS {Blk}
CSI Solar Co Ltd
410.0 W +5.0 W 44.9 V 20.81% 93.5%
Aptos Solar Technology LLC DNA-144-MF23-405W {Blk}
Aptos Solar Technology LLC
405.0 W Tie (0 W) 48.73 V 20.13% 90.8%
Aptos Solar Technology LLC DNA-144-MF23-405W {Wht}
Aptos Solar Technology LLC
405.0 W Tie (0 W) 48.73 V 20.77% 93.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SF405M?

Evaluate PEIMAR SF405M (405.0 W STC, 45.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SF405M reaches 51.33 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SF405M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SF405M 8 kW Residential Fit

Needs 20 modules (415 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3N-405MS {Wht}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 378.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SF405M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Why is PEIMAR SF405M PTC wattage (378.9 W) lower than STC (405.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 378.9 W PTC (93.6% retention) across PEIMAR SF405M's 1.93 m2 aperture.

Who should skip PEIMAR SF405M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 PEIMAR SF405M panels (415 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3N-405MS {Wht}.

What is the 1,000 V commercial string limit for PEIMAR SF405M?

On 1,000 V commercial inverters at -10 C (50.11 V cold Voc), PEIMAR SF405M fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SF405M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.