Skip to main content
WireAndSun
Calculators
CEC PV Module

CSI Solar Co Ltd CS3N-410MS {Blk} — CEC Solar Module Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd CS3N-410MS {Blk} is a 410.0 W STC (383.5 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 20.81% efficiency, 44.9 V Voc at 25 C, and 49.76 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
383.5 W
Voc @ 25C
44.9 V
Efficiency
20.81%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd CS3N-410MS {Blk} Compare Against Peer CEC Listings?

How CSI Solar Co Ltd CSI Solar Co Ltd CS3N-410MS {Blk} handles rooftop heat (383.5 W PTC), 8 kW sizing, and cold winter string voltage.

CSI Solar Co Ltd builds the CSI Solar Co Ltd CS3N-410MS {Blk} (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 208.1 W/m2 (0.90 percentage points above 19.91% CEC median). Compared against AXITEC AC-410MH/144V (410.0 W), this model holds strong 93.5% PTC-to-STC heat retention (#7,159 of 21,677). Mid-range 44.9 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 18.13 A overcurrent floor served by a 20 A breaker.

Where Does CSI Solar Co Ltd CS3N-410MS {Blk} Fall Across Listed CEC Models?

Where CSI Solar Co Ltd CS3N-410MS {Blk} (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CSI Solar Co Ltd CS3N-410MS {Blk} (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCSI Solar Co Ltd C: 410.0 W

What Dataset Percentiles Define CSI Solar Co Ltd CS3N-410MS {Blk}?

Percentile placement of CSI Solar Co Ltd CS3N-410MS {Blk} across power density (208.1 W/m2), thermal retention, and nameplate STC wattage.

CSI Solar Co Ltd CS3N-410MS {Blk} Engineering BenchmarksPercentile comparison of CSI Solar Co Ltd CS3N-410MS {Blk} wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.5%Module Efficiency20.81%

What Do the Dataset Ranks Show for CSI Solar Co Ltd CS3N-410MS {Blk}?

Four critical engineering numbers homeowners and solar installers check first when reviewing CSI Solar Co Ltd CS3N-410MS {Blk} specifications.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,197

20.81% Aperture Efficiency

Power density 208.1 W/m2 (0.90 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.76 V at -10 C (597.1 V string) and 51.14 V at -20 C (11 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 39.4 m2 (424 sq ft) producing 7,670 W PTC; NEC 690.8 OCPD floor is 18.13 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.9 * (1 + (-0.309/100) * (-10 - 25)) = 49.76 V | OCPD = 1.56 * 11.62 = 18.13 A

Inputs from CEC Modules.csv for CSI Solar Co Ltd CS3N-410MS {Blk}: Voc=44.9 V, beta_Voc=-0.309%/C, Isc=11.62 A, STC=410.0 W, Area=1.97 m2.

Result: 12 panels max on 600 V (597.1 V); 20 panels for 8 kW (424 sq ft).

What Are the Published CEC Specifications for CSI Solar Co Ltd CS3N-410MS {Blk}?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CSI Solar Co Ltd CS3N-410MS {Blk}.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd CS3N-410MS {Blk}.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 383.5 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.62 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.6 V / 10.92 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.309 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.81% (1.97 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many CSI Solar Co Ltd CS3N-410MS {Blk} Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CSI Solar Co Ltd CS3N-410MS {Blk} (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 318 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 424 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 530 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?

All closely matched CSI Solar Co Ltd wattages and cosmetic trims sharing the CSI Solar Co Ltd CS3N-410MS {Blk} architecture.

Sibling CEC listings grouped into the CSI Solar Co Ltd CS3N-410MS {Blk} wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
CSI Solar Co Ltd CS3N-400MS {Blk} 400.0 W 373.9 W 44.5 V 37.2 V 20.3%
CSI Solar Co Ltd CS3N-405MS {Blk} 405.0 W 378.7 W 44.7 V 37.4 V 20.56%
CSI Solar Co Ltd CS3N-410MS {Blk} 410.0 W 383.5 W 44.9 V 37.6 V 20.81%
CSI Solar Co Ltd CS3N-415MS 415.0 W 388.2 W 45.1 V 37.8 V 21.07%
CSI Solar Co Ltd CS3N-420MS 420.0 W 393.1 W 45.3 V 38.0 V 21.32%

How Many CSI Solar Co Ltd CS3N-410MS {Blk} Modules Fit in a Cold-Weather String?

Maximum series module counts for CSI Solar Co Ltd CS3N-410MS {Blk} from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.9V and beta_Voc=-0.309%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.14 V 11 panels 562.5 V 19 panels
-10 C (14 F) 49.76 V 12 panels 597.1 V 20 panels
0 C (32 F) 48.37 V 12 panels 580.4 V 20 panels
25 C (77 F STC) 44.9 V 13 panels 583.7 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS3N-410MS {Blk}?

Alternative CEC solar modules from competing brands near CSI Solar Co Ltd CS3N-410MS {Blk} (410.0 W), including AXITEC AC-410MH/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-410MH/144V
AXITEC
410.0 W Tie (0 W) 48.91 V 20.71% 93.5%
BYD Company Limited BYD400MIK-36
BYD Company Limited
410.0 W Tie (0 W) 49.21 V 20.4% 94.0%
AXITEC AC-410MB/144V
AXITEC
410.0 W Tie (0 W) 49.3 V 21.03% 93.0%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 49.4 V 21.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS3N-410MS {Blk}?

Evaluate CSI Solar Co Ltd CS3N-410MS {Blk} (410.0 W STC, 44.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS3N-410MS {Blk} reaches 51.14 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 424 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (424 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS3N-410MS {Blk} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CSI Solar Co Ltd CS3N-410MS {Blk} 8 kW Residential Fit

Needs 20 modules (424 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-410MH/144V.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CSI Solar Co Ltd CS3N-410MS {Blk} by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS3N-410MS {Blk}?

Multiplying CSI Solar Co Ltd CS3N-410MS {Blk}'s 11.62 A short-circuit current by 1.56 equals 18.13 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can CSI Solar Co Ltd CS3N-410MS {Blk} pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.76 V cold Voc at 14 F and handles 11.62 A Isc; string inverters cap CSI Solar Co Ltd CS3N-410MS {Blk} at 12 panels on 600 V.

Is CSI Solar Co Ltd CS3N-410MS {Blk} eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS3N-410MS {Blk} rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.