PEIMAR SE440M is a 440.0 W STC (413.1 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.95% efficiency, 41.0 V Voc at 25 C, and 44.76 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 413.1 W
- Voc @ 25C
- 41.0 V
- Efficiency
- 20.95%
How Does PEIMAR SE440M Compare Against Peer CEC Listings?
Engineering position of PEIMAR SE440M (440.0 W STC) vs. Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV across 5,889 CEC Mono-c-Si solar modules.
Ranking #6,418 across 21,677 CEC solar panels (top 31.6%; higher than 68.4% of peers), PEIMAR SE440M operates as a modern high-density residential and light-commercial module sitting 30.0 W above the 410.0 W Mono-c-Si median. Mid-range 41.0 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677), 19 panels occupy 429 sq ft and offset roughly $2,092/yr at average US rates (or $3,538/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does PEIMAR SE440M Fall Across Listed CEC Models?
Plots PEIMAR SE440M at 440.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define PEIMAR SE440M?
Benchmarks PEIMAR SE440M on STC wattage, thermal PTC/STC retention, and 20.95 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for PEIMAR SE440M?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR SE440M by PEIMAR.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.95% Aperture Efficiency
Power density 209.5 W/m2 (1.04 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.76 V at -10 C (581.9 V string) and 45.83 V at -20 C (13 max).
19 Panels = 8,360 W STC
Occupies 39.9 m2 (429 sq ft) producing 7,849 W PTC; NEC 690.8 OCPD floor is 21.17 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.0 * (1 + (-0.262/100) * (-10 - 25)) = 44.76 V | OCPD = 1.56 * 13.57 = 21.17 A
Inputs from CEC Modules.csv for PEIMAR SE440M: Voc=41.0 V, beta_Voc=-0.262%/C, Isc=13.57 A, STC=440.0 W, Area=2.1 m2.
Result: 13 panels max on 600 V (581.9 V); 19 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for PEIMAR SE440M?
Laboratory test ratings recorded for PEIMAR SE440M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 413.1 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.69 V / 12.68 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.262 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.95% (2.1 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many PEIMAR SE440M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (429 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR SE440M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 316 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 429 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 520 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?
Sibling wattage bins and frame colors grouped with PEIMAR SE440M under PEIMAR to prevent duplicate spec pages. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PEIMAR SE430M | 430.0 W | 403.5 W | 40.8 V | 34.5 V | 20.48% |
| PEIMAR SE435M | 435.0 W | 408.3 W | 40.9 V | 34.6 V | 20.71% |
| PEIMAR SE440M | 440.0 W | 413.1 W | 41.0 V | 34.69 V | 20.95% |
| PEIMAR SE445M | 445.0 W | 417.9 W | 41.1 V | 34.78 V | 21.19% |
How Many PEIMAR SE440M Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for PEIMAR SE440M (beta_Voc -0.262%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.83 V | 13 panels | 595.8 V | 21 panels |
| -10 C (14 F) | 44.76 V | 13 panels | 581.9 V | 22 panels |
| 0 C (32 F) | 43.69 V | 13 panels | 568.0 V | 22 panels |
| 25 C (77 F STC) | 41.0 V | 14 panels | 574.0 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR SE440M?
Closest cross-brand CEC competitors to PEIMAR SE440M matched near 440.0 W STC and 41.0 V Voc, led by Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV Changzhou EGing Photovoltaic Technology Co Ltd |
440.0 W | Tie (0 W) | 41.0 V | 20.37% | 93.7% |
| CertainTeed CTM10440HC11-06 CertainTeed |
440.0 W | Tie (0 W) | 41.02 V | 20.37% | 93.7% |
| CertainTeed CTM10440HC11-09 CertainTeed |
440.0 W | Tie (0 W) | 40.9 V | 20.56% | 93.7% |
| Elin Energy (Sirius PV) ELNSM60M-HC-440 Elin Energy (Sirius PV) |
440.0 W | Tie (0 W) | 41.12 V | 20.47% | 94.2% |
What Are the Design Limits and Best-Fit Uses for PEIMAR SE440M?
Evaluate PEIMAR SE440M (440.0 W STC, 41.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SE440M reaches 45.83 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 429 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (429 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PEIMAR SE440M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR SE440M 8 kW Residential Fit
Needs 19 modules (429 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 413.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR SE440M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
How many PEIMAR SE440M panels fit on a 600 V winter solar string?
At -10 C (14 F), PEIMAR SE440M cold Voc rises from 41.0 V to 44.76 V (beta_Voc -0.262%/C), capping a 600 V string at 13 panels (581.9 V).
How much roof area does an 8 kW array of PEIMAR SE440M need?
An 8 kW DC system uses 19 PEIMAR SE440M modules (8,360 W STC / 7,849 W PTC), covering roughly 429 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does PEIMAR SE440M compare against Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV?
PEIMAR SE440M outputs 440.0 W STC (41.0 V Voc, rank #6,418 of 21,677), while Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV delivers 440.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)