Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SE390M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SE390M is a 390.0 W STC (366.0 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.63% efficiency, 36.8 V Voc at 25 C, and 40.17 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
366.0 W
Voc @ 25C
36.8 V
Efficiency
20.63%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SE390M Compare Against Peer CEC Listings?

Engineering position of PEIMAR SE390M (390.0 W STC) vs. Apollo Renewables Inc Apollo-M754BH-390BB across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, PEIMAR SE390M pairs strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677) with 36.8 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,686 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Apollo Renewables Inc Apollo-M754BH-390BB offers a 390.0 W alternative.

Where Does PEIMAR SE390M Fall Across Listed CEC Models?

Plots PEIMAR SE390M at 390.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SE390M (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SE390M: 390.0 W

What Dataset Percentiles Define PEIMAR SE390M?

Benchmarks PEIMAR SE390M on STC wattage, thermal PTC/STC retention, and 20.63 aperture conversion efficiency against CEC peers.

PEIMAR SE390M Engineering BenchmarksPercentile comparison of PEIMAR SE390M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention93.8%Module Efficiency20.63%

What Do the Dataset Ranks Show for PEIMAR SE390M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR SE390M by PEIMAR.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,981

20.63% Aperture Efficiency

Power density 206.3 W/m2 (0.72 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.17 V at -10 C (562.4 V string) and 41.14 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 39.7 m2 (427 sq ft) producing 7,686 W PTC; NEC 690.8 OCPD floor is 20.92 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.8 * (1 + (-0.262/100) * (-10 - 25)) = 40.17 V | OCPD = 1.56 * 13.41 = 20.92 A

Inputs from CEC Modules.csv for PEIMAR SE390M: Voc=36.8 V, beta_Voc=-0.262%/C, Isc=13.41 A, STC=390.0 W, Area=1.89 m2.

Result: 14 panels max on 600 V (562.4 V); 21 panels for 8 kW (427 sq ft).

What Are the Published CEC Specifications for PEIMAR SE390M?

Laboratory test ratings recorded for PEIMAR SE390M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SE390M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 366.0 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.41 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.14 V / 12.53 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.262 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.63% (1.89 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SE390M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (427 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR SE390M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 326 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 427 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 529 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Sibling wattage bins and frame colors grouped with PEIMAR SE390M under PEIMAR to prevent duplicate spec pages. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the PEIMAR SE390M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SE385M 385.0 W 361.2 W 36.7 V 31.5 V 20.37%
PEIMAR SE390M 390.0 W 366.0 W 36.8 V 31.14 V 20.63%
PEIMAR SE395M 395.0 W 370.8 W 36.9 V 31.2 V 20.9%

How Many PEIMAR SE390M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PEIMAR SE390M (beta_Voc -0.262%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.8V and beta_Voc=-0.262%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.14 V 14 panels 576.0 V 24 panels
-10 C (14 F) 40.17 V 14 panels 562.4 V 24 panels
0 C (32 F) 39.21 V 15 panels 588.1 V 25 panels
25 C (77 F STC) 36.8 V 16 panels 588.8 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SE390M?

Closest cross-brand CEC competitors to PEIMAR SE390M matched near 390.0 W STC and 36.8 V Voc, led by Apollo Renewables Inc Apollo-M754BH-390BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Apollo Renewables Inc Apollo-M754BH-390BB
Apollo Renewables Inc
390.0 W Tie (0 W) 36.85 V 20.1% 93.7%
AXITEC AC-390MH/108VB
AXITEC
390.0 W Tie (0 W) 36.85 V 20.1% 93.7%
ELITE Solar ET-M754BH390BB
ELITE Solar
390.0 W Tie (0 W) 36.85 V 20.1% 93.7%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
390.0 W Tie (0 W) 36.45 V 20.53% 94.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SE390M?

Evaluate PEIMAR SE390M (390.0 W STC, 36.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SE390M reaches 41.14 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 427 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (427 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SE390M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SE390M 8 kW Residential Fit

Needs 21 modules (427 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Apollo Renewables Inc Apollo-M754BH-390BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 366.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SE390M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

What fuse or breaker size does NEC 690.8 require for PEIMAR SE390M?

Multiplying PEIMAR SE390M's 13.41 A short-circuit current by 1.56 equals 20.92 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SE390M before finalizing component orders.

Can PEIMAR SE390M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.17 V cold Voc at 14 F and handles 13.41 A Isc; string inverters cap PEIMAR SE390M at 14 panels on 600 V.

Is PEIMAR SE390M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SE390M rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.