AXITEC AC-390MH/108VB is a 390.0 W STC (365.3 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.1% efficiency, 36.85 V Voc at 25 C, and 40.28 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 390.0 W
- PTC Wattage
- 365.3 W
- Voc @ 25C
- 36.85 V
- Efficiency
- 20.1%
How Does AXITEC AC-390MH/108VB Compare Against Peer CEC Listings?
Solar engineering breakdown for AXITEC AC-390MH/108VB: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Measured at 390.0 W STC and 365.3 W PTC, AXITEC AC-390MH/108VB sits +5.0 W vs all-CEC median (top 49.5%; higher than 50.5% of peers) among 21,677 listed modules. Power density reaches 201.0 W/m2 (0.19 percentage points above 19.91% CEC median). Lower 36.85 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Apollo Renewables Inc Apollo-M754BH-390BB rates 390.0 W.
Where Does AXITEC AC-390MH/108VB Fall Across Listed CEC Models?
Distribution marker showing AXITEC AC-390MH/108VB (390.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define AXITEC AC-390MH/108VB?
Dataset percentiles tracking AXITEC AC-390MH/108VB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Do the Dataset Ranks Show for AXITEC AC-390MH/108VB?
Benchmark highlights for AXITEC AC-390MH/108VB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Top 49.5% STC Output
390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.1% Aperture Efficiency
Power density 201.0 W/m2 (0.19 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.28 V at -10 C (563.9 V string) and 41.26 V at -20 C (14 max).
21 Panels = 8,190 W STC
Occupies 40.7 m2 (439 sq ft) producing 7,671 W PTC; NEC 690.8 OCPD floor is 21.23 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.85 * (1 + (-0.266/100) * (-10 - 25)) = 40.28 V | OCPD = 1.56 * 13.61 = 21.23 A
Inputs from CEC Modules.csv for AXITEC AC-390MH/108VB: Voc=36.85 V, beta_Voc=-0.266%/C, Isc=13.61 A, STC=390.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (563.9 V); 21 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for AXITEC AC-390MH/108VB?
Official CEC datasheet figures for AXITEC AC-390MH/108VB (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 365.3 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.85 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.64 V / 12.73 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.1% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-390MH/108VB Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many AXITEC AC-390MH/108VB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.24 kW | 334 sq ft | $1,562 | $2,641 |
| 8 kW Class | 21 | 8.19 kW | 439 sq ft | $2,050 | $3,466 |
| 10 kW Class | 26 | 10.14 kW | 543 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Consolidated AXITEC wattage variants sharing the AXITEC AC-390MH/108VB mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-385MH/108VB | 385.0 W | 360.5 W | 36.7 V | 30.44 V | 19.85% |
| AXITEC AC-390MH/108VB | 390.0 W | 365.3 W | 36.85 V | 30.64 V | 20.1% |
| AXITEC AC-395MH/108VB | 395.0 W | 370.1 W | 36.98 V | 30.84 V | 20.36% |
How Many AXITEC AC-390MH/108VB Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-390MH/108VB (40.28 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.26 V | 14 panels | 577.6 V | 24 panels |
| -10 C (14 F) | 40.28 V | 14 panels | 563.9 V | 24 panels |
| 0 C (32 F) | 39.3 V | 15 panels | 589.5 V | 25 panels |
| 25 C (77 F STC) | 36.85 V | 16 panels | 589.6 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-390MH/108VB?
Competing CEC solar panels closest to AXITEC AC-390MH/108VB in nameplate wattage and Voc, starting with Apollo Renewables Inc Apollo-M754BH-390BB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M754BH-390BB Apollo Renewables Inc |
390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
| ELITE Solar ET-M754BH390BB ELITE Solar |
390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
390.0 W | Tie (0 W) | 36.45 V | 20.53% | 94.4% |
| CSI Solar Co Ltd CS6R-390MS-HL {Blk} CSI Solar Co Ltd |
390.0 W | Tie (0 W) | 36.4 V | 20.0% | 94.1% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-390MH/108VB?
Evaluate AXITEC AC-390MH/108VB (390.0 W STC, 36.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-390MH/108VB reaches 41.26 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-390MH/108VB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-390MH/108VB 8 kW Residential Fit
Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Apollo Renewables Inc Apollo-M754BH-390BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-390MH/108VB by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-390MH/108VB panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-390MH/108VB cold Voc rises from 36.85 V to 40.28 V (beta_Voc -0.266%/C), capping a 600 V string at 14 panels (563.9 V).
How much roof area does an 8 kW array of AXITEC AC-390MH/108VB need?
An 8 kW DC system uses 21 AXITEC AC-390MH/108VB modules (8,190 W STC / 7,671 W PTC), covering roughly 439 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does AXITEC AC-390MH/108VB compare against Apollo Renewables Inc Apollo-M754BH-390BB?
AXITEC AC-390MH/108VB outputs 390.0 W STC (36.85 V Voc, rank #10,321 of 21,677), while Apollo Renewables Inc Apollo-M754BH-390BB delivers 390.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)