Manufacturer: PANASONIC CORPORATION OF NORTH AMERICA Registry: CEC Verified Engineering Specification

PANASONIC CORPORATION OF NORTH AMERICA EVPV380 is a 380.0 W STC (361.5 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 22.49% efficiency, 44.3 V Voc at 25 C, and 47.96 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
361.5 W
Voc @ 25C
44.3 V
Efficiency
22.49%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV380 Compare Against Peer CEC Listings?

Solar engineering breakdown for PANASONIC CORPORATION OF NORTH AMERICA EVPV380: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 380.0 W STC and 361.5 W PTC, PANASONIC CORPORATION OF NORTH AMERICA EVPV380 sits -5.0 W vs all-CEC median (below all-CEC median; higher than 47.6% of peers) among 21,677 listed modules. Power density reaches 224.9 W/m2 (2.58 percentage points above 19.91% CEC median). Mid-range 44.3 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer CSI Solar Co Ltd CS3N-385MS {Blk} rates 385.0 W.

Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV380 Fall Across Listed CEC Models?

Distribution marker showing PANASONIC CORPORATION OF NORTH AMERICA EVPV380 (380.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PANASONIC CORPORATION OF NORTH AMERICA EVPV380 (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPANASONIC CORPORAT: 380.0 W

What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV380?

Dataset percentiles tracking PANASONIC CORPORATION OF NORTH AMERICA EVPV380 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

PANASONIC CORPORATION OF NORTH AMERICA EVPV380 Engineering BenchmarksPercentile comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV380 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention95.1%Module Efficiency22.49%

What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV380?

Benchmark highlights for PANASONIC CORPORATION OF NORTH AMERICA EVPV380 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,030

22.49% Aperture Efficiency

Power density 224.9 W/m2 (2.58 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.96 V at -10 C (575.5 V string) and 49.0 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 37.2 m2 (400 sq ft) producing 7,953 W PTC; NEC 690.8 OCPD floor is 16.55 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.3 * (1 + (-0.236/100) * (-10 - 25)) = 47.96 V | OCPD = 1.56 * 10.61 = 16.55 A

Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV380: Voc=44.3 V, beta_Voc=-0.236%/C, Isc=10.61 A, STC=380.0 W, Area=1.69 m2.

Result: 12 panels max on 600 V (575.5 V); 22 panels for 8 kW (400 sq ft).

What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV380?

Official CEC datasheet figures for PANASONIC CORPORATION OF NORTH AMERICA EVPV380 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for PANASONIC CORPORATION OF NORTH AMERICA EVPV380.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 361.5 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.61 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.1 V / 9.98 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.236 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.49% (1.69 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV380 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PANASONIC CORPORATION OF NORTH AMERICA EVPV380 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 291 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 400 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 491 sq ft $2,568 $4,342

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV380 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PANASONIC CORPORATION OF NORTH AMERICA EVPV380 (47.96 V at 14 F).

Computed from Voc=44.3V and beta_Voc=-0.236%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.0 V 12 panels 588.0 V 20 panels
-10 C (14 F) 47.96 V 12 panels 575.5 V 20 panels
0 C (32 F) 46.91 V 12 panels 562.9 V 21 panels
25 C (77 F STC) 44.3 V 13 panels 575.9 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV380?

Competing CEC solar panels closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV380 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3N-385MS {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3N-385MS {Blk}
CSI Solar Co Ltd
385.0 W +5.0 W 43.9 V 19.54% 93.4%
CSI Solar Co Ltd CS3N-385MS {Wht}
CSI Solar Co Ltd
385.0 W +5.0 W 43.9 V 19.54% 93.4%
CSI Solar Co Ltd CS6XH-375M
CSI Solar Co Ltd
375.0 W -5.0 W 45.6 V 20.27% 93.0%
EMMVEE Photovoltaic Power Private Limited E385M72-B
EMMVEE Photovoltaic Power Private Limited
385.0 W +5.0 W 45.9 V 19.32% 91.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV380?

Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV380 (380.0 W STC, 44.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV380 reaches 49.0 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 400 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (400 sq ft).
  • 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PANASONIC CORPORATION OF NORTH AMERICA EVPV380 8 kW Residential Fit

Needs 22 modules (400 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3N-385MS {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 361.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV380 by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.

How many PANASONIC CORPORATION OF NORTH AMERICA EVPV380 panels fit on a 600 V winter solar string?

At -10 C (14 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV380 cold Voc rises from 44.3 V to 47.96 V (beta_Voc -0.236%/C), capping a 600 V string at 12 panels (575.5 V).

How much roof area does an 8 kW array of PANASONIC CORPORATION OF NORTH AMERICA EVPV380 need?

An 8 kW DC system uses 22 PANASONIC CORPORATION OF NORTH AMERICA EVPV380 modules (8,360 W STC / 7,953 W PTC), covering roughly 400 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

How does PANASONIC CORPORATION OF NORTH AMERICA EVPV380 compare against CSI Solar Co Ltd CS3N-385MS {Blk}?

PANASONIC CORPORATION OF NORTH AMERICA EVPV380 outputs 380.0 W STC (44.3 V Voc, rank #11,043 of 21,677), while CSI Solar Co Ltd CS3N-385MS {Blk} delivers 385.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.