Skip to main content
WireAndSun
Calculators
CEC PV Module

CSI Solar Co Ltd CS6XH-375M — CEC Solar Module Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd CS6XH-375M is a 375.0 W STC (348.6 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.27% efficiency, 45.6 V Voc at 25 C, and 50.04 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
375.0 W
PTC Wattage
348.6 W
Voc @ 25C
45.6 V
Efficiency
20.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd CS6XH-375M Compare Against Peer CEC Listings?

Solar engineering breakdown for CSI Solar Co Ltd CS6XH-375M: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from CSI Solar Co Ltd and peers, CSI Solar Co Ltd CS6XH-375M stands 35.0 W below the 410.0 W Mono-c-Si median and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,502-$2,533/yr in baseline US bill offset. Mid-range 45.6 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does CSI Solar Co Ltd CS6XH-375M Fall Across Listed CEC Models?

Distribution marker showing CSI Solar Co Ltd CS6XH-375M (375.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CSI Solar Co Ltd CS6XH-375M (375.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCSI Solar Co Ltd C: 375.0 W

What Dataset Percentiles Define CSI Solar Co Ltd CS6XH-375M?

Dataset percentiles tracking CSI Solar Co Ltd CS6XH-375M power output, thermal retention ratio, and aperture efficiency against 21,677 models.

CSI Solar Co Ltd CS6XH-375M Engineering BenchmarksPercentile comparison of CSI Solar Co Ltd CS6XH-375M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage375.0 WPTC/STC Retention93.0%Module Efficiency20.27%

What Do the Dataset Ranks Show for CSI Solar Co Ltd CS6XH-375M?

Benchmark highlights for CSI Solar Co Ltd CS6XH-375M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #11,367 / 21,677

375.0 W STC · Higher Than 46.0%

375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,465

20.27% Aperture Efficiency

Power density 202.7 W/m2 (0.36 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.04 V at -10 C (550.4 V string) and 51.3 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,250 W STC

Occupies 40.7 m2 (438 sq ft) producing 7,669 W PTC; NEC 690.8 OCPD floor is 16.07 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.6 * (1 + (-0.278/100) * (-10 - 25)) = 50.04 V | OCPD = 1.56 * 10.3 = 16.07 A

Inputs from CEC Modules.csv for CSI Solar Co Ltd CS6XH-375M: Voc=45.6 V, beta_Voc=-0.278%/C, Isc=10.3 A, STC=375.0 W, Area=1.85 m2.

Result: 11 panels max on 600 V (550.4 V); 22 panels for 8 kW (438 sq ft).

What Are the Published CEC Specifications for CSI Solar Co Ltd CS6XH-375M?

Official CEC datasheet figures for CSI Solar Co Ltd CS6XH-375M (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd CS6XH-375M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 375.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 348.6 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.3 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.3 V / 9.8 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.278 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.27% (1.85 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many CSI Solar Co Ltd CS6XH-375M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many CSI Solar Co Ltd CS6XH-375M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.0 kW 319 sq ft $1,502 $2,539
8 kW Class 22 8.25 kW 438 sq ft $2,065 $3,492
10 kW Class 27 10.12 kW 538 sq ft $2,533 $4,283

How Many CSI Solar Co Ltd CS6XH-375M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on CSI Solar Co Ltd CS6XH-375M (50.04 V at 14 F).

Computed from Voc=45.6V and beta_Voc=-0.278%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.3 V 11 panels 564.3 V 19 panels
-10 C (14 F) 50.04 V 11 panels 550.4 V 19 panels
0 C (32 F) 48.77 V 12 panels 585.2 V 20 panels
25 C (77 F STC) 45.6 V 13 panels 592.8 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS6XH-375M?

Competing CEC solar panels closest to CSI Solar Co Ltd CS6XH-375M in nameplate wattage and Voc, starting with EMMVEE Photovoltaic Power Private Limited E370M72-B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
EMMVEE Photovoltaic Power Private Limited E370M72-B
EMMVEE Photovoltaic Power Private Limited
370.0 W -5.0 W 45.25 V 18.56% 91.4%
CertainTeed CT375M11-02
CertainTeed
375.0 W Tie (0 W) 47.85 V 19.93% 91.4%
Boviet Solar Technology Co Ltd BVM6612M-375
Boviet Solar Technology Co Ltd
375.0 W Tie (0 W) 48.0 V 19.33% 92.4%
AXITEC AC-375M/72S
AXITEC
375.0 W Tie (0 W) 48.16 V 19.33% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS6XH-375M?

Evaluate CSI Solar Co Ltd CS6XH-375M (375.0 W STC, 45.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS6XH-375M reaches 51.3 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 438 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (438 sq ft).
  • 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS6XH-375M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CSI Solar Co Ltd CS6XH-375M 8 kW Residential Fit

Needs 22 modules (438 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E370M72-B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 348.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CSI Solar Co Ltd CS6XH-375M by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS6XH-375M?

Multiplying CSI Solar Co Ltd CS6XH-375M's 10.3 A short-circuit current by 1.56 equals 16.07 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can CSI Solar Co Ltd CS6XH-375M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.04 V cold Voc at 14 F and handles 10.3 A Isc; string inverters cap CSI Solar Co Ltd CS6XH-375M at 11 panels on 600 V.

Is CSI Solar Co Ltd CS6XH-375M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS6XH-375M rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.