PANASONIC CORPORATION OF NORTH AMERICA EVPV370 is a 370.0 W STC (351.8 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 21.89% efficiency, 44.1 V Voc at 25 C, and 47.74 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 370.0 W
- PTC Wattage
- 351.8 W
- Voc @ 25C
- 44.1 V
- Efficiency
- 21.89%
How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV370 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PANASONIC CORPORATION OF NORTH AMERICA EVPV370 (Mono-c-Si) residential solar systems.
Homeowners evaluating PANASONIC CORPORATION OF NORTH AMERICA EVPV370 need 17 panels for 6 kW or 22 panels (400 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (400 sq ft). Under NEC 690.7(A), beta_Voc (-0.236%/C) pushes open-circuit voltage to 47.74 V at 14 F and 48.78 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV370 Fall Across Listed CEC Models?
Comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV370 (370.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV370?
Relative ranking of PANASONIC CORPORATION OF NORTH AMERICA EVPV370 across nameplate watts, 95.1% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV370?
Summary of PANASONIC CORPORATION OF NORTH AMERICA EVPV370 output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.
370.0 W STC · Higher Than 44.4%
370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.89% Aperture Efficiency
Power density 218.9 W/m2 (1.98 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 47.74 V at -10 C (572.9 V string) and 48.78 V at -20 C (12 max).
22 Panels = 8,140 W STC
Occupies 37.2 m2 (400 sq ft) producing 7,740 W PTC; NEC 690.8 OCPD floor is 16.46 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.1 * (1 + (-0.236/100) * (-10 - 25)) = 47.74 V | OCPD = 1.56 * 10.55 = 16.46 A
Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV370: Voc=44.1 V, beta_Voc=-0.236%/C, Isc=10.55 A, STC=370.0 W, Area=1.69 m2.
Result: 12 panels max on 600 V (572.9 V); 22 panels for 8 kW (400 sq ft).
What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV370?
Complete CEC test sheet for PANASONIC CORPORATION OF NORTH AMERICA EVPV370 including Isc (10.55 A), Voc (44.1 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 351.8 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.4 V / 9.9 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.236 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.89% (1.69 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV370 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PANASONIC CORPORATION OF NORTH AMERICA EVPV370.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.29 kW | 309 sq ft | $1,574 | $2,662 |
| 8 kW Class | 22 | 8.14 kW | 400 sq ft | $2,037 | $3,445 |
| 10 kW Class | 28 | 10.36 kW | 509 sq ft | $2,593 | $4,385 |
Which Sibling Wattage & Trim Variants Belong to This PANASONIC CORPORATION OF NORTH AMERICA Series?
Related PANASONIC CORPORATION OF NORTH AMERICA power steps and black/silver trims consolidated into this PANASONIC CORPORATION OF NORTH AMERICA EVPV370 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PANASONIC CORPORATION OF NORTH AMERICA EVPV360 | 360.0 W | 342.0 W | 43.9 V | 36.7 V | 21.3% |
| PANASONIC CORPORATION OF NORTH AMERICA EVPV370 | 370.0 W | 351.8 W | 44.1 V | 37.4 V | 21.89% |
How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV370 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for PANASONIC CORPORATION OF NORTH AMERICA EVPV370 (44.1 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 48.78 V | 12 panels | 585.4 V | 20 panels |
| -10 C (14 F) | 47.74 V | 12 panels | 572.9 V | 20 panels |
| 0 C (32 F) | 46.7 V | 12 panels | 560.4 V | 21 panels |
| 25 C (77 F STC) | 44.1 V | 13 panels | 573.3 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV370?
Four comparable CEC modules such as EMMVEE Photovoltaic Power Private Limited E370M72-B (370.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| EMMVEE Photovoltaic Power Private Limited E370M72-B EMMVEE Photovoltaic Power Private Limited |
370.0 W | Tie (0 W) | 45.25 V | 18.56% | 91.4% |
| CSI Solar Co Ltd CS6XH-375M CSI Solar Co Ltd |
375.0 W | +5.0 W | 45.6 V | 20.27% | 93.0% |
| CSI Solar Co Ltd CS6XH-360M CSI Solar Co Ltd |
360.0 W | -10.0 W | 45.0 V | 19.46% | 92.8% |
| CertainTeed CT370M00-04 CertainTeed |
370.0 W | Tie (0 W) | 47.9 V | 19.66% | 93.2% |
What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV370?
Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV370 (370.0 W STC, 44.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV370 reaches 48.78 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 400 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (400 sq ft).
- 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV370 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PANASONIC CORPORATION OF NORTH AMERICA EVPV370 8 kW Residential Fit
Needs 22 modules (400 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E370M72-B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 351.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV370 by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.
Why is PANASONIC CORPORATION OF NORTH AMERICA EVPV370 PTC wattage (351.8 W) lower than STC (370.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 351.8 W PTC (95.1% retention) across PANASONIC CORPORATION OF NORTH AMERICA EVPV370's 1.69 m2 aperture.
Who should skip PANASONIC CORPORATION OF NORTH AMERICA EVPV370 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 PANASONIC CORPORATION OF NORTH AMERICA EVPV370 panels (400 sq ft) leave unusable roof gaps vs. EMMVEE Photovoltaic Power Private Limited E370M72-B.
What is the 1,000 V commercial string limit for PANASONIC CORPORATION OF NORTH AMERICA EVPV370?
On 1,000 V commercial inverters at -10 C (47.74 V cold Voc), PANASONIC CORPORATION OF NORTH AMERICA EVPV370 fits up to 20 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)