Manufacturer: PANASONIC CORPORATION OF NORTH AMERICA Registry: CEC Verified Engineering Specification

PANASONIC CORPORATION OF NORTH AMERICA EVPV370 is a 370.0 W STC (351.8 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 21.89% efficiency, 44.1 V Voc at 25 C, and 47.74 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
370.0 W
PTC Wattage
351.8 W
Voc @ 25C
44.1 V
Efficiency
21.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV370 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PANASONIC CORPORATION OF NORTH AMERICA EVPV370 (Mono-c-Si) residential solar systems.

Homeowners evaluating PANASONIC CORPORATION OF NORTH AMERICA EVPV370 need 17 panels for 6 kW or 22 panels (400 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (400 sq ft). Under NEC 690.7(A), beta_Voc (-0.236%/C) pushes open-circuit voltage to 47.74 V at 14 F and 48.78 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV370 Fall Across Listed CEC Models?

Comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV370 (370.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PANASONIC CORPORATION OF NORTH AMERICA EVPV370 (370.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPANASONIC CORPORAT: 370.0 W

What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV370?

Relative ranking of PANASONIC CORPORATION OF NORTH AMERICA EVPV370 across nameplate watts, 95.1% PTC thermal ratio, and module aperture efficiency.

PANASONIC CORPORATION OF NORTH AMERICA EVPV370 Engineering BenchmarksPercentile comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV370 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage370.0 WPTC/STC Retention95.1%Module Efficiency21.89%

What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV370?

Summary of PANASONIC CORPORATION OF NORTH AMERICA EVPV370 output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,697 / 21,677

370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,388

21.89% Aperture Efficiency

Power density 218.9 W/m2 (1.98 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.74 V at -10 C (572.9 V string) and 48.78 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,140 W STC

Occupies 37.2 m2 (400 sq ft) producing 7,740 W PTC; NEC 690.8 OCPD floor is 16.46 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.1 * (1 + (-0.236/100) * (-10 - 25)) = 47.74 V | OCPD = 1.56 * 10.55 = 16.46 A

Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV370: Voc=44.1 V, beta_Voc=-0.236%/C, Isc=10.55 A, STC=370.0 W, Area=1.69 m2.

Result: 12 panels max on 600 V (572.9 V); 22 panels for 8 kW (400 sq ft).

What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV370?

Complete CEC test sheet for PANASONIC CORPORATION OF NORTH AMERICA EVPV370 including Isc (10.55 A), Voc (44.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PANASONIC CORPORATION OF NORTH AMERICA EVPV370.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 370.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 351.8 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.4 V / 9.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.236 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.89% (1.69 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV370 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PANASONIC CORPORATION OF NORTH AMERICA EVPV370.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.29 kW 309 sq ft $1,574 $2,662
8 kW Class 22 8.14 kW 400 sq ft $2,037 $3,445
10 kW Class 28 10.36 kW 509 sq ft $2,593 $4,385

Which Sibling Wattage & Trim Variants Belong to This PANASONIC CORPORATION OF NORTH AMERICA Series?

Related PANASONIC CORPORATION OF NORTH AMERICA power steps and black/silver trims consolidated into this PANASONIC CORPORATION OF NORTH AMERICA EVPV370 series guide.

Sibling CEC listings grouped into the PANASONIC CORPORATION OF NORTH AMERICA EVPV370 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PANASONIC CORPORATION OF NORTH AMERICA EVPV360 360.0 W 342.0 W 43.9 V 36.7 V 21.3%
PANASONIC CORPORATION OF NORTH AMERICA EVPV370 370.0 W 351.8 W 44.1 V 37.4 V 21.89%

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV370 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PANASONIC CORPORATION OF NORTH AMERICA EVPV370 (44.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.1V and beta_Voc=-0.236%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 48.78 V 12 panels 585.4 V 20 panels
-10 C (14 F) 47.74 V 12 panels 572.9 V 20 panels
0 C (32 F) 46.7 V 12 panels 560.4 V 21 panels
25 C (77 F STC) 44.1 V 13 panels 573.3 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV370?

Four comparable CEC modules such as EMMVEE Photovoltaic Power Private Limited E370M72-B (370.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
EMMVEE Photovoltaic Power Private Limited E370M72-B
EMMVEE Photovoltaic Power Private Limited
370.0 W Tie (0 W) 45.25 V 18.56% 91.4%
CSI Solar Co Ltd CS6XH-375M
CSI Solar Co Ltd
375.0 W +5.0 W 45.6 V 20.27% 93.0%
CSI Solar Co Ltd CS6XH-360M
CSI Solar Co Ltd
360.0 W -10.0 W 45.0 V 19.46% 92.8%
CertainTeed CT370M00-04
CertainTeed
370.0 W Tie (0 W) 47.9 V 19.66% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV370?

Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV370 (370.0 W STC, 44.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV370 reaches 48.78 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 400 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (400 sq ft).
  • 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV370 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PANASONIC CORPORATION OF NORTH AMERICA EVPV370 8 kW Residential Fit

Needs 22 modules (400 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E370M72-B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 351.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV370 by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.

Why is PANASONIC CORPORATION OF NORTH AMERICA EVPV370 PTC wattage (351.8 W) lower than STC (370.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 351.8 W PTC (95.1% retention) across PANASONIC CORPORATION OF NORTH AMERICA EVPV370's 1.69 m2 aperture.

Who should skip PANASONIC CORPORATION OF NORTH AMERICA EVPV370 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 PANASONIC CORPORATION OF NORTH AMERICA EVPV370 panels (400 sq ft) leave unusable roof gaps vs. EMMVEE Photovoltaic Power Private Limited E370M72-B.

What is the 1,000 V commercial string limit for PANASONIC CORPORATION OF NORTH AMERICA EVPV370?

On 1,000 V commercial inverters at -10 C (47.74 V cold Voc), PANASONIC CORPORATION OF NORTH AMERICA EVPV370 fits up to 20 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.