Skip to main content
WireAndSun
Calculators
CEC PV Module

PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK — CEC Solar Module Specifications

Manufacturer: PANASONIC CORPORATION OF NORTH AMERICA Registry: CEC Verified Engineering Specification

PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK is a 350.0 W STC (326.4 W PTC) Mono-c-Si solar module ranking #13,031 of 21,677 CEC listings (below all-CEC median; higher than 38.6% of peers). It delivers 19.77% efficiency, 40.3 V Voc at 25 C, and 44.05 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
350.0 W
PTC Wattage
326.4 W
Voc @ 25C
40.3 V
Efficiency
19.77%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK Compare Against Peer CEC Listings?

Solar engineering breakdown for PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 350.0 W STC and 326.4 W PTC, PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK sits -35.0 W vs all-CEC median (below all-CEC median; higher than 38.6% of peers) among 21,677 listed modules. Power density reaches 197.7 W/m2 (0.14 percentage points below 19.91% CEC median). Mid-range 40.3 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer CSI Solar Co Ltd CS3L-360MS rates 360.0 W.

Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK Fall Across Listed CEC Models?

Distribution marker showing PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK (350.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK (350.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPANASONIC CORPORAT: 350.0 W

What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK?

Dataset percentiles tracking PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK power output, thermal retention ratio, and aperture efficiency against 21,677 models.

PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK Engineering BenchmarksPercentile comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage350.0 WPTC/STC Retention93.3%Module Efficiency19.77%

What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK?

Benchmark highlights for PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #13,031 / 21,677

350.0 W STC · Higher Than 38.6%

350.0 W STC (-35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,307

19.77% Aperture Efficiency

Power density 197.7 W/m2 (0.14 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.05 V at -10 C (572.6 V string) and 45.12 V at -20 C (13 max).

8 kW Reference Array

23 Panels = 8,050 W STC

Occupies 40.7 m2 (438 sq ft) producing 7,507 W PTC; NEC 690.8 OCPD floor is 17.32 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.3 * (1 + (-0.266/100) * (-10 - 25)) = 44.05 V | OCPD = 1.56 * 11.1 = 17.32 A

Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK: Voc=40.3 V, beta_Voc=-0.266%/C, Isc=11.1 A, STC=350.0 W, Area=1.77 m2.

Result: 13 panels max on 600 V (572.6 V); 23 panels for 8 kW (438 sq ft).

What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK?

Official CEC datasheet figures for PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 350.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 326.4 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.1 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.3 V / 10.58 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.77% (1.77 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.3 kW 343 sq ft $1,577 $2,666
8 kW Class 23 8.05 kW 438 sq ft $2,015 $3,407
10 kW Class 29 10.15 kW 553 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This PANASONIC CORPORATION OF NORTH AMERICA Series?

Consolidated PANASONIC CORPORATION OF NORTH AMERICA wattage variants sharing the PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK mechanical and cell layout.

Sibling CEC listings grouped into the PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK 350.0 W 326.4 W 40.3 V 33.3 V 19.77%
PANASONIC CORPORATION OF NORTH AMERICA EVPV360PK 360.0 W 336.0 W 40.6 V 33.9 V 20.34%
PANASONIC CORPORATION OF NORTH AMERICA EVPV370PK 370.0 W 345.6 W 41.0 V 34.7 V 20.9%

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK (44.05 V at 14 F).

Computed from Voc=40.3V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.12 V 13 panels 586.6 V 22 panels
-10 C (14 F) 44.05 V 13 panels 572.6 V 22 panels
0 C (32 F) 42.98 V 13 panels 558.7 V 23 panels
25 C (77 F STC) 40.3 V 14 panels 564.2 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK?

Competing CEC solar panels closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3L-360MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3L-360MS
CSI Solar Co Ltd
360.0 W +10.0 W 40.4 V 20.11% 93.0%
Apollo Renewables Inc Apollo-M660BH-360BB
Apollo Renewables Inc
360.0 W +10.0 W 40.5 V 20.0% 93.6%
AXITEC AC-360MH/120V
AXITEC
360.0 W +10.0 W 40.5 V 19.89% 92.3%
AXITEC AC-360MH/120VB
AXITEC
360.0 W +10.0 W 40.5 V 19.89% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK?

Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK (350.0 W STC, 40.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK reaches 45.12 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 438 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (438 sq ft).
  • 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK 8 kW Residential Fit

Needs 23 modules (438 sq ft) with a 20 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3L-360MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 326.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.

How many PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK panels fit on a 600 V winter solar string?

At -10 C (14 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK cold Voc rises from 40.3 V to 44.05 V (beta_Voc -0.266%/C), capping a 600 V string at 13 panels (572.6 V).

How much roof area does an 8 kW array of PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK need?

An 8 kW DC system uses 23 PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK modules (8,050 W STC / 7,507 W PTC), covering roughly 438 sq ft and saving ~$2,015/yr at 18.54 c/kWh.

How does PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK compare against CSI Solar Co Ltd CS3L-360MS?

PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK outputs 350.0 W STC (40.3 V Voc, rank #13,031 of 21,677), while CSI Solar Co Ltd CS3L-360MS delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.