Miasole FLEX-03 290W is a 290.0 W STC (250.8 W PTC) CIGS solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 13.12% efficiency, 47.2 V Voc at 25 C, and 53.06 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 250.8 W
- Voc @ 25C
- 47.2 V
- Efficiency
- 13.12%
How Does Miasole FLEX-03 290W Compare Against Peer CEC Listings?
How Miasole Miasole FLEX-03 290W handles rooftop heat (250.8 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Miasole FLEX-03 290W exhibits 9.27 A short-circuit current, requiring a 14.46 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #17,253 of 21,677 (10.0 W below the 300.0 W CIGS median), this compact residential or specialty off-grid module covers 61.9 m2 for an 8 kW system (35 panels for 10 kW). Mid-range 47.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Miasole FLEX-03 290W Fall Across Listed CEC Models?
Where Miasole FLEX-03 290W (290.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Miasole FLEX-03 290W?
Percentile placement of Miasole FLEX-03 290W across power density (131.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Miasole FLEX-03 290W?
Four critical engineering numbers homeowners and solar installers check first when reviewing Miasole FLEX-03 290W specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 300.0 W CIGS median.
13.12% Aperture Efficiency
Power density 131.2 W/m2 (6.79 percentage points below 19.91% CEC median). PTC/STC ratio: 86.5% (rank #21,624).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.06 V at -10 C (583.7 V string) and 54.74 V at -20 C (10 max).
28 Panels = 8,120 W STC
Occupies 61.9 m2 (666 sq ft) producing 7,022 W PTC; NEC 690.8 OCPD floor is 14.46 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.2 * (1 + (-0.355/100) * (-10 - 25)) = 53.06 V | OCPD = 1.56 * 9.27 = 14.46 A
Inputs from CEC Modules.csv for Miasole FLEX-03 290W: Voc=47.2 V, beta_Voc=-0.355%/C, Isc=9.27 A, STC=290.0 W, Area=2.211 m2.
Result: 11 panels max on 600 V (583.7 V); 28 panels for 8 kW (666 sq ft).
What Are the Published CEC Specifications for Miasole FLEX-03 290W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Miasole FLEX-03 290W.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 250.8 W (86.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.27 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.2 V / 7.83 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.355 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.12% (2.211 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (CIGS) | Monofacial backsheet |
How Many Miasole FLEX-03 290W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Miasole FLEX-03 290W (290.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 500 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 666 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 833 sq ft | $2,540 | $4,296 |
How Many Miasole FLEX-03 290W Modules Fit in a Cold-Weather String?
Maximum series module counts for Miasole FLEX-03 290W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.74 V | 10 panels | 547.4 V | 18 panels |
| -10 C (14 F) | 53.06 V | 11 panels | 583.7 V | 18 panels |
| 0 C (32 F) | 51.39 V | 11 panels | 565.3 V | 19 panels |
| 25 C (77 F STC) | 47.2 V | 12 panels | 566.4 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Miasole FLEX-03 290W?
Alternative CEC solar modules from competing brands near Miasole FLEX-03 290W (290.0 W), including AXITEC AC-290M/156-72S. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-290M/156-72S AXITEC |
290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
| Gintung Energy GTEC-290G6S Gintung Energy |
290.0 W | Tie (0 W) | 44.84 V | 14.83% | 89.7% |
| Gintung Energy GTEC-290G6M Gintung Energy |
290.0 W | Tie (0 W) | 44.61 V | 14.83% | 89.6% |
| Centrosolar America DM72 290 Centrosolar America |
290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |
What Are the Design Limits and Best-Fit Uses for Miasole FLEX-03 290W?
Evaluate Miasole FLEX-03 290W (290.0 W STC, 47.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Miasole FLEX-03 290W reaches 54.74 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 666 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (666 sq ft).
- 2026 tax credit baseline: cash residential installs of Miasole FLEX-03 290W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Miasole FLEX-03 290W 8 kW Residential Fit
Needs 28 modules (666 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-290M/156-72S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Miasole FLEX-03 290W by Miasole grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Miasole FLEX-03 290W PTC wattage (250.8 W) lower than STC (290.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 250.8 W PTC (86.5% retention) across Miasole FLEX-03 290W's 2.211 m2 aperture.
Who should skip Miasole FLEX-03 290W on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Miasole FLEX-03 290W panels (666 sq ft) leave unusable roof gaps vs. AXITEC AC-290M/156-72S.
What is the 1,000 V commercial string limit for Miasole FLEX-03 290W?
On 1,000 V commercial inverters at -10 C (53.06 V cold Voc), Miasole FLEX-03 290W fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Miasole FLEX-03 290W.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)