Skip to main content
WireAndSun
Calculators
CEC PV Module

Miasole FLEX-03 310W — CEC Solar Module Specifications

Manufacturer: Miasole Registry: CEC Verified Engineering Specification

Miasole FLEX-03 310W is a 310.0 W STC (268.6 W PTC) CIGS solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 14.02% efficiency, 48.7 V Voc at 25 C, and 54.75 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
268.6 W
Voc @ 25C
48.7 V
Efficiency
14.02%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Miasole FLEX-03 310W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Miasole FLEX-03 310W (CIGS) residential solar systems.

Miasole FLEX-03 310W delivers 140.2 W/m2 (5.89 percentage points below 19.91% CEC median) and typical 86.6% PTC-to-STC thermal output (268.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (619 sq ft). At -4 F (-20 C), string voltage climbs to 56.48 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Boviet Solar Technology Co Ltd BVM6612P-310 (310.0 W).

Where Does Miasole FLEX-03 310W Fall Across Listed CEC Models?

Comparison of Miasole FLEX-03 310W (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Miasole FLEX-03 310W (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMiasole FLEX-03 31: 310.0 W

What Dataset Percentiles Define Miasole FLEX-03 310W?

Relative ranking of Miasole FLEX-03 310W across nameplate watts, 86.6% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Miasole FLEX-03 310W Engineering BenchmarksPercentile comparison of Miasole FLEX-03 310W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention86.6%Module Efficiency14.02%

What Do the Dataset Ranks Show for Miasole FLEX-03 310W?

Summary of Miasole FLEX-03 310W output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 300.0 W CIGS median.

Eff #20,896

14.02% Aperture Efficiency

Power density 140.2 W/m2 (5.89 percentage points below 19.91% CEC median). PTC/STC ratio: 86.6% (rank #21,610).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.75 V at -10 C (547.5 V string) and 56.48 V at -20 C (10 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 57.5 m2 (619 sq ft) producing 6,984 W PTC; NEC 690.8 OCPD floor is 14.26 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.355/100) * (-10 - 25)) = 54.75 V | OCPD = 1.56 * 9.14 = 14.26 A

Inputs from CEC Modules.csv for Miasole FLEX-03 310W: Voc=48.7 V, beta_Voc=-0.355%/C, Isc=9.14 A, STC=310.0 W, Area=2.211 m2.

Result: 10 panels max on 600 V (547.5 V); 26 panels for 8 kW (619 sq ft).

What Are the Published CEC Specifications for Miasole FLEX-03 310W?

Complete CEC test sheet for Miasole FLEX-03 310W including Isc (9.14 A), Voc (48.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Miasole FLEX-03 310W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 268.6 W (86.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.14 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.0 V / 7.96 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.355 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.02% (2.211 m2) Array roof footprint density
Cell Count & Technology 72 cells (CIGS) Monofacial backsheet

How Many Miasole FLEX-03 310W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Miasole FLEX-03 310W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 476 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 619 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 785 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Miasole Series?

Related Miasole power steps and black/silver trims consolidated into this Miasole FLEX-03 310W series guide. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Miasole FLEX-03 310W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Miasole FLEX-03 300W 300.0 W 259.7 W 48.0 V 38.1 V 13.57%
Miasole FLEX-03 310W 310.0 W 268.6 W 48.7 V 39.0 V 14.02%
Miasole FLEX-03 320W 320.0 W 277.6 W 49.5 V 40.0 V 14.47%

How Many Miasole FLEX-03 310W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Miasole FLEX-03 310W (48.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.7V and beta_Voc=-0.355%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.48 V 10 panels 564.8 V 17 panels
-10 C (14 F) 54.75 V 10 panels 547.5 V 18 panels
0 C (32 F) 53.02 V 11 panels 583.2 V 18 panels
25 C (77 F STC) 48.7 V 12 panels 584.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Miasole FLEX-03 310W?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6612P-310 (310.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612P-310
Boviet Solar Technology Co Ltd
310.0 W Tie (0 W) 45.8 V 15.98% 90.3%
Centrosolar America CP72 310-C1
Centrosolar America
310.0 W Tie (0 W) 45.8 V 15.98% 90.3%
BYD Company Limited BYD 310P6C-36
BYD Company Limited
310.0 W Tie (0 W) 45.79 V 15.98% 91.2%
BYD Company Limited BYD310P6K-36
BYD Company Limited
310.0 W Tie (0 W) 45.79 V 15.98% 91.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Miasole FLEX-03 310W?

Evaluate Miasole FLEX-03 310W (310.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Miasole FLEX-03 310W reaches 56.48 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 619 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (619 sq ft).
  • 2026 tax credit baseline: cash residential installs of Miasole FLEX-03 310W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Miasole FLEX-03 310W 8 kW Residential Fit

Needs 26 modules (619 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612P-310.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 268.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Miasole FLEX-03 310W by Miasole grounded in CEC test data and NEC 690.7/690.8 limits.

How many Miasole FLEX-03 310W panels fit on a 600 V winter solar string?

At -10 C (14 F), Miasole FLEX-03 310W cold Voc rises from 48.7 V to 54.75 V (beta_Voc -0.355%/C), capping a 600 V string at 10 panels (547.5 V).

How much roof area does an 8 kW array of Miasole FLEX-03 310W need?

An 8 kW DC system uses 26 Miasole FLEX-03 310W modules (8,060 W STC / 6,984 W PTC), covering roughly 619 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does Miasole FLEX-03 310W compare against Boviet Solar Technology Co Ltd BVM6612P-310?

Miasole FLEX-03 310W outputs 310.0 W STC (48.7 V Voc, rank #15,760 of 21,677), while Boviet Solar Technology Co Ltd BVM6612P-310 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.