Skip to main content
WireAndSun
Calculators
CEC PV Module

Miasole FLEX-03 280NL — CEC Solar Module Specifications

Manufacturer: Miasole Registry: CEC Verified Engineering Specification

Miasole FLEX-03 280NL is a 280.0 W STC (258.8 W PTC) CIGS solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 13.61% efficiency, 88.7 V Voc at 25 C, and 95.75 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
280.0 W
PTC Wattage
258.8 W
Voc @ 25C
88.7 V
Efficiency
13.61%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Miasole FLEX-03 280NL Compare Against Peer CEC Listings?

Solar engineering breakdown for Miasole FLEX-03 280NL: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Across 8 CIGS listings from Miasole and peers, Miasole FLEX-03 280NL stands 20.0 W below the 300.0 W CIGS median and strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,542-$2,523/yr in baseline US bill offset. Higher 88.7 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C).

Where Does Miasole FLEX-03 280NL Fall Across Listed CEC Models?

Distribution marker showing Miasole FLEX-03 280NL (280.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Miasole FLEX-03 280NL (280.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMiasole FLEX-03 28: 280.0 W

What Dataset Percentiles Define Miasole FLEX-03 280NL?

Dataset percentiles tracking Miasole FLEX-03 280NL power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Miasole FLEX-03 280NL Engineering BenchmarksPercentile comparison of Miasole FLEX-03 280NL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage280.0 WPTC/STC Retention92.4%Module Efficiency13.61%

What Do the Dataset Ranks Show for Miasole FLEX-03 280NL?

Benchmark highlights for Miasole FLEX-03 280NL covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #17,941 / 21,677

280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 300.0 W CIGS median.

Eff #21,150

13.61% Aperture Efficiency

Power density 136.1 W/m2 (6.30 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 95.75 V at -10 C (574.5 V string) and 97.76 V at -20 C (6 max).

8 kW Reference Array

29 Panels = 8,120 W STC

Occupies 59.7 m2 (642 sq ft) producing 7,505 W PTC; NEC 690.8 OCPD floor is 7.16 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 88.7 * (1 + (-0.227/100) * (-10 - 25)) = 95.75 V | OCPD = 1.56 * 4.59 = 7.16 A

Inputs from CEC Modules.csv for Miasole FLEX-03 280NL: Voc=88.7 V, beta_Voc=-0.227%/C, Isc=4.59 A, STC=280.0 W, Area=2.057 m2.

Result: 6 panels max on 600 V (574.5 V); 29 panels for 8 kW (642 sq ft).

What Are the Published CEC Specifications for Miasole FLEX-03 280NL?

Official CEC datasheet figures for Miasole FLEX-03 280NL (CIGS) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Miasole FLEX-03 280NL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 280.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 258.8 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 88.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 4.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 70.8 V / 3.96 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.227 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.61% (2.057 m2) Array roof footprint density
Cell Count & Technology 132 cells (CIGS) Monofacial backsheet

How Many Miasole FLEX-03 280NL Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Miasole FLEX-03 280NL modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.16 kW 487 sq ft $1,542 $2,607
8 kW Class 29 8.12 kW 642 sq ft $2,032 $3,437
10 kW Class 36 10.08 kW 797 sq ft $2,523 $4,266

How Many Miasole FLEX-03 280NL Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Miasole FLEX-03 280NL (95.75 V at 14 F).

Computed from Voc=88.7V and beta_Voc=-0.227%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 97.76 V 6 panels 586.6 V 10 panels
-10 C (14 F) 95.75 V 6 panels 574.5 V 10 panels
0 C (32 F) 93.73 V 6 panels 562.4 V 10 panels
25 C (77 F STC) 88.7 V 6 panels 532.2 V 11 panels

Which Cross-Brand Solar Modules Compare Closest to Miasole FLEX-03 280NL?

Competing CEC solar panels closest to Miasole FLEX-03 280NL in nameplate wattage and Voc, starting with Gintung Energy ASEC-285G6S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-285G6S
Gintung Energy
285.0 W +5.0 W 44.69 V 14.57% 89.7%
Gintung Energy ASEC-285G6M
Gintung Energy
285.0 W +5.0 W 44.53 V 14.57% 89.5%
AXITEC AC-285P/156-72S
AXITEC
285.0 W +5.0 W 44.51 V 14.72% 90.0%
Centrosolar America DP72 285
Centrosolar America
285.0 W +5.0 W 44.32 V 14.66% 88.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Miasole FLEX-03 280NL?

Evaluate Miasole FLEX-03 280NL (280.0 W STC, 88.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Miasole FLEX-03 280NL reaches 97.76 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 642 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (642 sq ft).
  • 2026 tax credit baseline: cash residential installs of Miasole FLEX-03 280NL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Miasole FLEX-03 280NL 8 kW Residential Fit

Needs 29 modules (642 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Gintung Energy ASEC-285G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 258.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Miasole FLEX-03 280NL by Miasole grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Miasole FLEX-03 280NL?

Multiplying Miasole FLEX-03 280NL's 4.59 A short-circuit current by 1.56 equals 7.16 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Miasole FLEX-03 280NL pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 95.75 V cold Voc at 14 F and handles 4.59 A Isc; string inverters cap Miasole FLEX-03 280NL at 6 panels on 600 V.

Is Miasole FLEX-03 280NL eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Miasole FLEX-03 280NL rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.