Miasole FLEX-03 470W is a 470.0 W STC (412.4 W PTC) CIGS solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 15.67% efficiency, 74.8 V Voc at 25 C, and 81.27 V cold Voc at -10 C (7 panels max per 600 V string).
- STC Wattage
- 470.0 W
- PTC Wattage
- 412.4 W
- Voc @ 25C
- 74.8 V
- Efficiency
- 15.67%
How Does Miasole FLEX-03 470W Compare Against Peer CEC Listings?
How Miasole Miasole FLEX-03 470W handles rooftop heat (412.4 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Miasole FLEX-03 470W exhibits 9.19 A short-circuit current, requiring a 14.34 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #4,967 of 21,677 (170.0 W above the 300.0 W CIGS median), this modern high-density residential and light-commercial module covers 54.0 m2 for an 8 kW system (22 panels for 10 kW). Higher 74.8 V open-circuit voltage caps 600 V residential strings at 7 panels at 14 F (-10 C).
Where Does Miasole FLEX-03 470W Fall Across Listed CEC Models?
Where Miasole FLEX-03 470W (470.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Miasole FLEX-03 470W?
Percentile placement of Miasole FLEX-03 470W across power density (156.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Miasole FLEX-03 470W?
Four critical engineering numbers homeowners and solar installers check first when reviewing Miasole FLEX-03 470W specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Top 23.4% STC Output
470.0 W STC (+85.0 W vs all-CEC median) vs 300.0 W CIGS median.
15.67% Aperture Efficiency
Power density 156.7 W/m2 (4.24 percentage points below 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).
7 Panels Max @ -10 C (600 V)
Cold Voc reaches 81.27 V at -10 C (568.9 V string) and 83.11 V at -20 C (7 max).
18 Panels = 8,460 W STC
Occupies 54.0 m2 (581 sq ft) producing 7,423 W PTC; NEC 690.8 OCPD floor is 14.34 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 74.8 * (1 + (-0.247/100) * (-10 - 25)) = 81.27 V | OCPD = 1.56 * 9.19 = 14.34 A
Inputs from CEC Modules.csv for Miasole FLEX-03 470W: Voc=74.8 V, beta_Voc=-0.247%/C, Isc=9.19 A, STC=470.0 W, Area=3.0 m2.
Result: 7 panels max on 600 V (568.9 V); 18 panels for 8 kW (581 sq ft).
What Are the Published CEC Specifications for Miasole FLEX-03 470W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Miasole FLEX-03 470W.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 412.4 W (87.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 74.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 59.6 V / 7.91 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.247 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.67% (3.0 m2) | Array roof footprint density |
| Cell Count & Technology | 112 cells (CIGS) | Monofacial backsheet |
How Many Miasole FLEX-03 470W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Miasole FLEX-03 470W (470.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.11 kW | 420 sq ft | $1,529 | $2,586 |
| 8 kW Class | 18 | 8.46 kW | 581 sq ft | $2,117 | $3,580 |
| 10 kW Class | 22 | 10.34 kW | 710 sq ft | $2,588 | $4,376 |
How Many Miasole FLEX-03 470W Modules Fit in a Cold-Weather String?
Maximum series module counts for Miasole FLEX-03 470W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 83.11 V | 7 panels | 581.8 V | 12 panels |
| -10 C (14 F) | 81.27 V | 7 panels | 568.9 V | 12 panels |
| 0 C (32 F) | 79.42 V | 7 panels | 555.9 V | 12 panels |
| 25 C (77 F STC) | 74.8 V | 8 panels | 598.4 V | 13 panels |
Which Cross-Brand Solar Modules Compare Closest to Miasole FLEX-03 470W?
Alternative CEC solar modules from competing brands near Miasole FLEX-03 470W (470.0 W), including Heliene 96M475. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Heliene 96M475 Heliene |
475.0 W | +5.0 W | 62.39 V | 18.85% | 90.5% |
| Heliene 96M460 Heliene |
460.0 W | -10.0 W | 61.79 V | 18.25% | 90.4% |
| CSI Solar Co Ltd CS3Y-470MS CSI Solar Co Ltd |
470.0 W | Tie (0 W) | 52.5 V | 20.52% | 93.5% |
| CSI Solar Co Ltd CS3Y-480P CSI Solar Co Ltd |
480.0 W | +10.0 W | 52.8 V | 20.96% | 93.2% |
What Are the Design Limits and Best-Fit Uses for Miasole FLEX-03 470W?
Evaluate Miasole FLEX-03 470W (470.0 W STC, 74.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Miasole FLEX-03 470W reaches 83.11 V per panel—exceeding 7 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 581 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (581 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Miasole FLEX-03 470W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Miasole FLEX-03 470W 8 kW Residential Fit
Needs 18 modules (581 sq ft) with a 15 A string OCPD, offsetting ~$2,117/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 7 panels (-10 C) or 7 panels (-20 C), or compare Heliene 96M475.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Miasole FLEX-03 470W by Miasole grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Miasole FLEX-03 470W PTC wattage (412.4 W) lower than STC (470.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 412.4 W PTC (87.7% retention) across Miasole FLEX-03 470W's 3.0 m2 aperture.
Who should skip Miasole FLEX-03 470W on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Miasole FLEX-03 470W panels (581 sq ft) leave unusable roof gaps vs. Heliene 96M475.
What is the 1,000 V commercial string limit for Miasole FLEX-03 470W?
On 1,000 V commercial inverters at -10 C (81.27 V cold Voc), Miasole FLEX-03 470W fits up to 12 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Miasole FLEX-03 470W.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)