Skip to main content
WireAndSun
Calculators
CEC PV Module

Miasole FLEX-03 470W — CEC Solar Module Specifications

Manufacturer: Miasole Registry: CEC Verified Engineering Specification

Miasole FLEX-03 470W is a 470.0 W STC (412.4 W PTC) CIGS solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 15.67% efficiency, 74.8 V Voc at 25 C, and 81.27 V cold Voc at -10 C (7 panels max per 600 V string).

STC Wattage
470.0 W
PTC Wattage
412.4 W
Voc @ 25C
74.8 V
Efficiency
15.67%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Miasole FLEX-03 470W Compare Against Peer CEC Listings?

How Miasole Miasole FLEX-03 470W handles rooftop heat (412.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Miasole FLEX-03 470W exhibits 9.19 A short-circuit current, requiring a 14.34 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #4,967 of 21,677 (170.0 W above the 300.0 W CIGS median), this modern high-density residential and light-commercial module covers 54.0 m2 for an 8 kW system (22 panels for 10 kW). Higher 74.8 V open-circuit voltage caps 600 V residential strings at 7 panels at 14 F (-10 C).

Where Does Miasole FLEX-03 470W Fall Across Listed CEC Models?

Where Miasole FLEX-03 470W (470.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Miasole FLEX-03 470W (470.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMiasole FLEX-03 47: 470.0 W

What Dataset Percentiles Define Miasole FLEX-03 470W?

Percentile placement of Miasole FLEX-03 470W across power density (156.7 W/m2), thermal retention, and nameplate STC wattage.

Miasole FLEX-03 470W Engineering BenchmarksPercentile comparison of Miasole FLEX-03 470W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage470.0 WPTC/STC Retention87.7%Module Efficiency15.67%

What Do the Dataset Ranks Show for Miasole FLEX-03 470W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Miasole FLEX-03 470W specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #4,967 / 21,677

Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 300.0 W CIGS median.

Eff #18,676

15.67% Aperture Efficiency

Power density 156.7 W/m2 (4.24 percentage points below 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).

NEC 690.7 Limit

7 Panels Max @ -10 C (600 V)

Cold Voc reaches 81.27 V at -10 C (568.9 V string) and 83.11 V at -20 C (7 max).

8 kW Reference Array

18 Panels = 8,460 W STC

Occupies 54.0 m2 (581 sq ft) producing 7,423 W PTC; NEC 690.8 OCPD floor is 14.34 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 74.8 * (1 + (-0.247/100) * (-10 - 25)) = 81.27 V | OCPD = 1.56 * 9.19 = 14.34 A

Inputs from CEC Modules.csv for Miasole FLEX-03 470W: Voc=74.8 V, beta_Voc=-0.247%/C, Isc=9.19 A, STC=470.0 W, Area=3.0 m2.

Result: 7 panels max on 600 V (568.9 V); 18 panels for 8 kW (581 sq ft).

What Are the Published CEC Specifications for Miasole FLEX-03 470W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Miasole FLEX-03 470W.

Official California Energy Commission (NREL SAM) test parameters for Miasole FLEX-03 470W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 470.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 412.4 W (87.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 74.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.19 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 59.6 V / 7.91 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.247 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.67% (3.0 m2) Array roof footprint density
Cell Count & Technology 112 cells (CIGS) Monofacial backsheet

How Many Miasole FLEX-03 470W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Miasole FLEX-03 470W (470.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.11 kW 420 sq ft $1,529 $2,586
8 kW Class 18 8.46 kW 581 sq ft $2,117 $3,580
10 kW Class 22 10.34 kW 710 sq ft $2,588 $4,376

How Many Miasole FLEX-03 470W Modules Fit in a Cold-Weather String?

Maximum series module counts for Miasole FLEX-03 470W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=74.8V and beta_Voc=-0.247%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 83.11 V 7 panels 581.8 V 12 panels
-10 C (14 F) 81.27 V 7 panels 568.9 V 12 panels
0 C (32 F) 79.42 V 7 panels 555.9 V 12 panels
25 C (77 F STC) 74.8 V 8 panels 598.4 V 13 panels

Which Cross-Brand Solar Modules Compare Closest to Miasole FLEX-03 470W?

Alternative CEC solar modules from competing brands near Miasole FLEX-03 470W (470.0 W), including Heliene 96M475. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 96M475
Heliene
475.0 W +5.0 W 62.39 V 18.85% 90.5%
Heliene 96M460
Heliene
460.0 W -10.0 W 61.79 V 18.25% 90.4%
CSI Solar Co Ltd CS3Y-470MS
CSI Solar Co Ltd
470.0 W Tie (0 W) 52.5 V 20.52% 93.5%
CSI Solar Co Ltd CS3Y-480P
CSI Solar Co Ltd
480.0 W +10.0 W 52.8 V 20.96% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Miasole FLEX-03 470W?

Evaluate Miasole FLEX-03 470W (470.0 W STC, 74.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Miasole FLEX-03 470W reaches 83.11 V per panel—exceeding 7 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 581 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (581 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Miasole FLEX-03 470W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Miasole FLEX-03 470W 8 kW Residential Fit

Needs 18 modules (581 sq ft) with a 15 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 7 panels (-10 C) or 7 panels (-20 C), or compare Heliene 96M475.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Miasole FLEX-03 470W by Miasole grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Miasole FLEX-03 470W PTC wattage (412.4 W) lower than STC (470.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 412.4 W PTC (87.7% retention) across Miasole FLEX-03 470W's 3.0 m2 aperture.

Who should skip Miasole FLEX-03 470W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Miasole FLEX-03 470W panels (581 sq ft) leave unusable roof gaps vs. Heliene 96M475.

What is the 1,000 V commercial string limit for Miasole FLEX-03 470W?

On 1,000 V commercial inverters at -10 C (81.27 V cold Voc), Miasole FLEX-03 470W fits up to 12 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Miasole FLEX-03 470W.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.