Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanersun Energy Co Ltd HN21RN-48HT440W — CEC Solar Module Specifications

Manufacturer: Hanersun Energy Co Ltd Registry: CEC Verified Engineering Specification

Hanersun Energy Co Ltd HN21RN-48HT440W is a 440.0 W STC (418.2 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 22.68% efficiency, 35.33 V Voc at 25 C, and 38.72 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
418.2 W
Voc @ 25C
35.33 V
Efficiency
22.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanersun Energy Co Ltd HN21RN-48HT440W Compare Against Peer CEC Listings?

How Hanersun Energy Co Ltd Hanersun Energy Co Ltd HN21RN-48HT440W handles rooftop heat (418.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Hanersun Energy Co Ltd HN21RN-48HT440W exhibits 15.88 A short-circuit current, requiring a 24.77 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #6,418 of 21,677 (30.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 36.9 m2 for an 8 kW system (23 panels for 10 kW). Lower 35.33 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.

Where Does Hanersun Energy Co Ltd HN21RN-48HT440W Fall Across Listed CEC Models?

Where Hanersun Energy Co Ltd HN21RN-48HT440W (440.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanersun Energy Co Ltd HN21RN-48HT440W (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanersun Energy Co: 440.0 W

What Dataset Percentiles Define Hanersun Energy Co Ltd HN21RN-48HT440W?

Percentile placement of Hanersun Energy Co Ltd HN21RN-48HT440W across power density (226.8 W/m2), thermal retention, and nameplate STC wattage.

Hanersun Energy Co Ltd HN21RN-48HT440W Engineering BenchmarksPercentile comparison of Hanersun Energy Co Ltd HN21RN-48HT440W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention95.0%Module Efficiency22.68%

What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN21RN-48HT440W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hanersun Energy Co Ltd HN21RN-48HT440W specifications.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,656

22.68% Aperture Efficiency

Power density 226.8 W/m2 (2.77 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 38.72 V at -10 C (580.8 V string) and 39.69 V at -20 C (15 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 36.9 m2 (397 sq ft) producing 7,946 W PTC; NEC 690.8 OCPD floor is 24.77 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.33 * (1 + (-0.274/100) * (-10 - 25)) = 38.72 V | OCPD = 1.56 * 15.88 = 24.77 A

Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN21RN-48HT440W: Voc=35.33 V, beta_Voc=-0.274%/C, Isc=15.88 A, STC=440.0 W, Area=1.94 m2.

Result: 15 panels max on 600 V (580.8 V); 19 panels for 8 kW (397 sq ft).

What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN21RN-48HT440W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hanersun Energy Co Ltd HN21RN-48HT440W.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Energy Co Ltd HN21RN-48HT440W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 418.2 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 35.33 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 15.88 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.46 V / 14.94 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.274 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.68% (1.94 m2) Array roof footprint density
Cell Count & Technology 48 cells (Mono-c-Si) Monofacial backsheet

How Many Hanersun Energy Co Ltd HN21RN-48HT440W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hanersun Energy Co Ltd HN21RN-48HT440W (440.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 292 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 397 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 480 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?

All closely matched Hanersun Energy Co Ltd wattages and cosmetic trims sharing the Hanersun Energy Co Ltd HN21RN-48HT440W architecture.

Sibling CEC listings grouped into the Hanersun Energy Co Ltd HN21RN-48HT440W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanersun Energy Co Ltd HN21RN-48HT430W 430.0 W 408.5 W 34.93 V 29.14 V 22.16%
Hanersun Energy Co Ltd HN21RN-48HT435W 435.0 W 413.3 W 35.13 V 29.3 V 22.42%
Hanersun Energy Co Ltd HN21RN-48HT440W 440.0 W 418.2 W 35.33 V 29.46 V 22.68%
Hanersun Energy Co Ltd HN21RN-48HT445W 445.0 W 423.0 W 35.53 V 29.62 V 22.94%

How Many Hanersun Energy Co Ltd HN21RN-48HT440W Modules Fit in a Cold-Weather String?

Maximum series module counts for Hanersun Energy Co Ltd HN21RN-48HT440W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=35.33V and beta_Voc=-0.274%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 39.69 V 15 panels 595.3 V 25 panels
-10 C (14 F) 38.72 V 15 panels 580.8 V 25 panels
0 C (32 F) 37.75 V 15 panels 566.2 V 26 panels
25 C (77 F STC) 35.33 V 16 panels 565.3 V 28 panels

Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN21RN-48HT440W?

Alternative CEC solar modules from competing brands near Hanersun Energy Co Ltd HN21RN-48HT440W (440.0 W), including ELITE Solar ET-NR48TBH440GB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ELITE Solar ET-NR48TBH440GB
ELITE Solar
440.0 W Tie (0 W) 35.29 V 22.0% 95.0%
ELITE Solar ET-NR48TBH440GL
ELITE Solar
440.0 W Tie (0 W) 35.29 V 22.0% 95.0%
CSI Solar Co Ltd CS62-48TM-440H
CSI Solar Co Ltd
440.0 W Tie (0 W) 35.4 V 22.8% 94.9%
CSI Solar Co Ltd CS61-54TM-440H
CSI Solar Co Ltd
440.0 W Tie (0 W) 38.5 V 22.22% 94.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN21RN-48HT440W?

Evaluate Hanersun Energy Co Ltd HN21RN-48HT440W (440.0 W STC, 35.33 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN21RN-48HT440W reaches 39.69 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 397 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (397 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN21RN-48HT440W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanersun Energy Co Ltd HN21RN-48HT440W 8 kW Residential Fit

Needs 19 modules (397 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare ELITE Solar ET-NR48TBH440GB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 418.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Energy Co Ltd HN21RN-48HT440W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hanersun Energy Co Ltd HN21RN-48HT440W PTC wattage (418.2 W) lower than STC (440.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 418.2 W PTC (95.0% retention) across Hanersun Energy Co Ltd HN21RN-48HT440W's 1.94 m2 aperture.

Who should skip Hanersun Energy Co Ltd HN21RN-48HT440W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 Hanersun Energy Co Ltd HN21RN-48HT440W panels (397 sq ft) leave unusable roof gaps vs. ELITE Solar ET-NR48TBH440GB.

What is the 1,000 V commercial string limit for Hanersun Energy Co Ltd HN21RN-48HT440W?

On 1,000 V commercial inverters at -10 C (38.72 V cold Voc), Hanersun Energy Co Ltd HN21RN-48HT440W fits up to 25 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.