CSI Solar Co Ltd CS61-54TM-440H is a 440.0 W STC (416.7 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 22.22% efficiency, 38.5 V Voc at 25 C, and 41.83 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 416.7 W
- Voc @ 25C
- 38.5 V
- Efficiency
- 22.22%
How Does CSI Solar Co Ltd CS61-54TM-440H Compare Against Peer CEC Listings?
Solar engineering breakdown for CSI Solar Co Ltd CS61-54TM-440H: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 440.0 W STC and 416.7 W PTC, CSI Solar Co Ltd CS61-54TM-440H sits +55.0 W vs all-CEC median (top 31.6%; higher than 68.4% of peers) among 21,677 listed modules. Power density reaches 222.2 W/m2 (2.31 percentage points above 19.91% CEC median). Lower 38.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer Bluesun Solar CoLtd BSM440M10-54HNH rates 440.0 W.
Where Does CSI Solar Co Ltd CS61-54TM-440H Fall Across Listed CEC Models?
Distribution marker showing CSI Solar Co Ltd CS61-54TM-440H (440.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CSI Solar Co Ltd CS61-54TM-440H?
Dataset percentiles tracking CSI Solar Co Ltd CS61-54TM-440H power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS61-54TM-440H?
Benchmark highlights for CSI Solar Co Ltd CS61-54TM-440H covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.22% Aperture Efficiency
Power density 222.2 W/m2 (2.31 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.83 V at -10 C (585.6 V string) and 42.78 V at -20 C (14 max).
19 Panels = 8,360 W STC
Occupies 37.6 m2 (405 sq ft) producing 7,917 W PTC; NEC 690.8 OCPD floor is 22.48 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.5 * (1 + (-0.247/100) * (-10 - 25)) = 41.83 V | OCPD = 1.56 * 14.41 = 22.48 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS61-54TM-440H: Voc=38.5 V, beta_Voc=-0.247%/C, Isc=14.41 A, STC=440.0 W, Area=1.98 m2.
Result: 14 panels max on 600 V (585.6 V); 19 panels for 8 kW (405 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS61-54TM-440H?
Official CEC datasheet figures for CSI Solar Co Ltd CS61-54TM-440H (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 416.7 W (94.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.41 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.6 V / 13.52 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.247 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.22% (1.98 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS61-54TM-440H Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CSI Solar Co Ltd CS61-54TM-440H modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 298 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 405 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 490 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Consolidated CSI Solar Co Ltd wattage variants sharing the CSI Solar Co Ltd CS61-54TM-440H mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS61-54TM-430H | 430.0 W | 407.0 W | 38.1 V | 32.2 V | 21.72% |
| CSI Solar Co Ltd CS61-54TM-435H | 435.0 W | 411.8 W | 38.3 V | 32.5 V | 21.97% |
| CSI Solar Co Ltd CS61-54TM-440H | 440.0 W | 416.7 W | 38.5 V | 32.6 V | 22.22% |
| CSI Solar Co Ltd CS61-54TM-445H | 445.0 W | 421.5 W | 38.7 V | 32.8 V | 22.47% |
How Many CSI Solar Co Ltd CS61-54TM-440H Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CSI Solar Co Ltd CS61-54TM-440H (41.83 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.78 V | 14 panels | 598.9 V | 23 panels |
| -10 C (14 F) | 41.83 V | 14 panels | 585.6 V | 23 panels |
| 0 C (32 F) | 40.88 V | 14 panels | 572.3 V | 24 panels |
| 25 C (77 F STC) | 38.5 V | 15 panels | 577.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS61-54TM-440H?
Competing CEC solar panels closest to CSI Solar Co Ltd CS61-54TM-440H in nameplate wattage and Voc, starting with Bluesun Solar CoLtd BSM440M10-54HNH.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM440M10-54HNH Bluesun Solar CoLtd |
440.0 W | Tie (0 W) | 38.9 V | 22.68% | 95.1% |
| Aptos Solar Technology LLC DNA-108-MFN10-440W Aptos Solar Technology LLC |
440.0 W | Tie (0 W) | 39.0 V | 22.68% | 95.1% |
| AEG SOLAR ENERGY SRL ALPS54D30-440/TP AEG SOLAR ENERGY SRL |
440.0 W | Tie (0 W) | 39.5 V | 22.11% | 94.3% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW440M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
440.0 W | Tie (0 W) | 39.79 V | 23.16% | 94.7% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS61-54TM-440H?
Evaluate CSI Solar Co Ltd CS61-54TM-440H (440.0 W STC, 38.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS61-54TM-440H reaches 42.78 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 405 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (405 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS61-54TM-440H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS61-54TM-440H 8 kW Residential Fit
Needs 19 modules (405 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Bluesun Solar CoLtd BSM440M10-54HNH.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 416.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS61-54TM-440H by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many CSI Solar Co Ltd CS61-54TM-440H panels fit on a 600 V winter solar string?
At -10 C (14 F), CSI Solar Co Ltd CS61-54TM-440H cold Voc rises from 38.5 V to 41.83 V (beta_Voc -0.247%/C), capping a 600 V string at 14 panels (585.6 V).
How much roof area does an 8 kW array of CSI Solar Co Ltd CS61-54TM-440H need?
An 8 kW DC system uses 19 CSI Solar Co Ltd CS61-54TM-440H modules (8,360 W STC / 7,917 W PTC), covering roughly 405 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does CSI Solar Co Ltd CS61-54TM-440H compare against Bluesun Solar CoLtd BSM440M10-54HNH?
CSI Solar Co Ltd CS61-54TM-440H outputs 440.0 W STC (38.5 V Voc, rank #6,418 of 21,677), while Bluesun Solar CoLtd BSM440M10-54HNH delivers 440.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)