CSI Solar Co Ltd CS62-48TM-440H is a 440.0 W STC (417.7 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 22.8% efficiency, 35.4 V Voc at 25 C, and 37.21 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 417.7 W
- Voc @ 25C
- 35.4 V
- Efficiency
- 22.8%
How Does CSI Solar Co Ltd CS62-48TM-440H Compare Against Peer CEC Listings?
Solar engineering breakdown for CSI Solar Co Ltd CS62-48TM-440H: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from CSI Solar Co Ltd and peers, CSI Solar Co Ltd CS62-48TM-440H stands 30.0 W above the 410.0 W Mono-c-Si median and strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,542-$2,533/yr in baseline US bill offset. Lower 35.4 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters.
Where Does CSI Solar Co Ltd CS62-48TM-440H Fall Across Listed CEC Models?
Distribution marker showing CSI Solar Co Ltd CS62-48TM-440H (440.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CSI Solar Co Ltd CS62-48TM-440H?
Dataset percentiles tracking CSI Solar Co Ltd CS62-48TM-440H power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS62-48TM-440H?
Benchmark highlights for CSI Solar Co Ltd CS62-48TM-440H covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.8% Aperture Efficiency
Power density 228.0 W/m2 (2.89 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 37.21 V at -10 C (595.4 V string) and 37.73 V at -20 C (15 max).
19 Panels = 8,360 W STC
Occupies 36.7 m2 (395 sq ft) producing 7,936 W PTC; NEC 690.8 OCPD floor is 24.46 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 35.4 * (1 + (-0.146/100) * (-10 - 25)) = 37.21 V | OCPD = 1.56 * 15.68 = 24.46 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS62-48TM-440H: Voc=35.4 V, beta_Voc=-0.146%/C, Isc=15.68 A, STC=440.0 W, Area=1.93 m2.
Result: 16 panels max on 600 V (595.4 V); 19 panels for 8 kW (395 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS62-48TM-440H?
Official CEC datasheet figures for CSI Solar Co Ltd CS62-48TM-440H (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 417.7 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 35.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.68 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.2 V / 14.58 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.146 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.8% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS62-48TM-440H Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CSI Solar Co Ltd CS62-48TM-440H modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 291 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 395 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 478 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Consolidated CSI Solar Co Ltd wattage variants sharing the CSI Solar Co Ltd CS62-48TM-440H mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS62-48TM-430H | 430.0 W | 408.0 W | 35.0 V | 29.8 V | 22.28% |
| CSI Solar Co Ltd CS62-48TM-435H | 435.0 W | 412.8 W | 35.2 V | 30.0 V | 22.54% |
| CSI Solar Co Ltd CS62-48TM-440H | 440.0 W | 417.7 W | 35.4 V | 30.2 V | 22.8% |
| CSI Solar Co Ltd CS62-48TM-445H | 445.0 W | 422.5 W | 35.6 V | 30.4 V | 23.06% |
How Many CSI Solar Co Ltd CS62-48TM-440H Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CSI Solar Co Ltd CS62-48TM-440H (37.21 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 37.73 V | 15 panels | 565.9 V | 26 panels |
| -10 C (14 F) | 37.21 V | 16 panels | 595.4 V | 26 panels |
| 0 C (32 F) | 36.69 V | 16 panels | 587.0 V | 27 panels |
| 25 C (77 F STC) | 35.4 V | 16 panels | 566.4 V | 28 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS62-48TM-440H?
Competing CEC solar panels closest to CSI Solar Co Ltd CS62-48TM-440H in nameplate wattage and Voc, starting with ELITE Solar ET-NR48TBH440GB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ELITE Solar ET-NR48TBH440GB ELITE Solar |
440.0 W | Tie (0 W) | 35.29 V | 22.0% | 95.0% |
| ELITE Solar ET-NR48TBH440GL ELITE Solar |
440.0 W | Tie (0 W) | 35.29 V | 22.0% | 95.0% |
| Bluesun Solar CoLtd BSM440M10-54HNH Bluesun Solar CoLtd |
440.0 W | Tie (0 W) | 38.9 V | 22.68% | 95.1% |
| Aptos Solar Technology LLC DNA-108-MFN10-440W Aptos Solar Technology LLC |
440.0 W | Tie (0 W) | 39.0 V | 22.68% | 95.1% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS62-48TM-440H?
Evaluate CSI Solar Co Ltd CS62-48TM-440H (440.0 W STC, 35.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS62-48TM-440H reaches 37.73 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 395 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (395 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS62-48TM-440H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS62-48TM-440H 8 kW Residential Fit
Needs 19 modules (395 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare ELITE Solar ET-NR48TBH440GB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 417.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS62-48TM-440H by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS62-48TM-440H?
Multiplying CSI Solar Co Ltd CS62-48TM-440H's 15.68 A short-circuit current by 1.56 equals 24.46 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can CSI Solar Co Ltd CS62-48TM-440H pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 37.21 V cold Voc at 14 F and handles 15.68 A Isc; string inverters cap CSI Solar Co Ltd CS62-48TM-440H at 16 panels on 600 V.
Is CSI Solar Co Ltd CS62-48TM-440H eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS62-48TM-440H rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)