ELITE Solar ET-NR48TBH440GL is a 440.0 W STC (418.0 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 22.0% efficiency, 35.29 V Voc at 25 C, and 37.97 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 418.0 W
- Voc @ 25C
- 35.29 V
- Efficiency
- 22.0%
How Does ELITE Solar ET-NR48TBH440GL Compare Against Peer CEC Listings?
How ELITE Solar ELITE Solar ET-NR48TBH440GL handles rooftop heat (418.0 W PTC), 8 kW sizing, and cold winter string voltage.
ELITE Solar builds the ELITE Solar ET-NR48TBH440GL (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 220.0 W/m2 (2.09 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS62-48TM-440H (440.0 W), this model holds strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Lower 35.29 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 24.63 A overcurrent floor served by a 25 A breaker.
Where Does ELITE Solar ET-NR48TBH440GL Fall Across Listed CEC Models?
Where ELITE Solar ET-NR48TBH440GL (440.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define ELITE Solar ET-NR48TBH440GL?
Percentile placement of ELITE Solar ET-NR48TBH440GL across power density (220.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for ELITE Solar ET-NR48TBH440GL?
Four critical engineering numbers homeowners and solar installers check first when reviewing ELITE Solar ET-NR48TBH440GL specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.0% Aperture Efficiency
Power density 220.0 W/m2 (2.09 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 37.97 V at -10 C (569.5 V string) and 38.74 V at -20 C (15 max).
19 Panels = 8,360 W STC
Occupies 38.0 m2 (409 sq ft) producing 7,942 W PTC; NEC 690.8 OCPD floor is 24.63 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 35.29 * (1 + (-0.217/100) * (-10 - 25)) = 37.97 V | OCPD = 1.56 * 15.79 = 24.63 A
Inputs from CEC Modules.csv for ELITE Solar ET-NR48TBH440GL: Voc=35.29 V, beta_Voc=-0.217%/C, Isc=15.79 A, STC=440.0 W, Area=2.0 m2.
Result: 15 panels max on 600 V (569.5 V); 19 panels for 8 kW (409 sq ft).
What Are the Published CEC Specifications for ELITE Solar ET-NR48TBH440GL?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for ELITE Solar ET-NR48TBH440GL.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 418.0 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 35.29 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.38 V / 14.98 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.217 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.0% (2.0 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many ELITE Solar ET-NR48TBH440GL Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using ELITE Solar ET-NR48TBH440GL (440.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 301 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 409 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 495 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This ELITE Solar Series?
All closely matched ELITE Solar wattages and cosmetic trims sharing the ELITE Solar ET-NR48TBH440GL architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| ELITE Solar ET-NR48TBH430GL | 430.0 W | 408.3 W | 34.89 V | 29.0 V | 21.5% |
| ELITE Solar ET-NR48TBH435GL | 435.0 W | 413.1 W | 35.09 V | 29.18 V | 21.75% |
| ELITE Solar ET-NR48TBH440GL | 440.0 W | 418.0 W | 35.29 V | 29.38 V | 22.0% |
| ELITE Solar ET-NR48TBH445GL | 445.0 W | 422.9 W | 35.49 V | 29.57 V | 22.25% |
How Many ELITE Solar ET-NR48TBH440GL Modules Fit in a Cold-Weather String?
Maximum series module counts for ELITE Solar ET-NR48TBH440GL from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 38.74 V | 15 panels | 581.1 V | 25 panels |
| -10 C (14 F) | 37.97 V | 15 panels | 569.5 V | 26 panels |
| 0 C (32 F) | 37.2 V | 16 panels | 595.2 V | 26 panels |
| 25 C (77 F STC) | 35.29 V | 17 panels | 599.9 V | 28 panels |
Which Cross-Brand Solar Modules Compare Closest to ELITE Solar ET-NR48TBH440GL?
Alternative CEC solar modules from competing brands near ELITE Solar ET-NR48TBH440GL (440.0 W), including CSI Solar Co Ltd CS62-48TM-440H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS62-48TM-440H CSI Solar Co Ltd |
440.0 W | Tie (0 W) | 35.4 V | 22.8% | 94.9% |
| CSI Solar Co Ltd CS61-54TM-440H CSI Solar Co Ltd |
440.0 W | Tie (0 W) | 38.5 V | 22.22% | 94.7% |
| Bluesun Solar CoLtd BSM440M10-54HNH Bluesun Solar CoLtd |
440.0 W | Tie (0 W) | 38.9 V | 22.68% | 95.1% |
| Aptos Solar Technology LLC DNA-108-MFN10-440W Aptos Solar Technology LLC |
440.0 W | Tie (0 W) | 39.0 V | 22.68% | 95.1% |
What Are the Design Limits and Best-Fit Uses for ELITE Solar ET-NR48TBH440GL?
Evaluate ELITE Solar ET-NR48TBH440GL (440.0 W STC, 35.29 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), ELITE Solar ET-NR48TBH440GL reaches 38.74 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (409 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of ELITE Solar ET-NR48TBH440GL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
ELITE Solar ET-NR48TBH440GL 8 kW Residential Fit
Needs 19 modules (409 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare CSI Solar Co Ltd CS62-48TM-440H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 418.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for ELITE Solar ET-NR48TBH440GL by ELITE Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for ELITE Solar ET-NR48TBH440GL?
Multiplying ELITE Solar ET-NR48TBH440GL's 15.79 A short-circuit current by 1.56 equals 24.63 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can ELITE Solar ET-NR48TBH440GL pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 37.97 V cold Voc at 14 F and handles 15.79 A Isc; string inverters cap ELITE Solar ET-NR48TBH440GL at 15 panels on 600 V.
Is ELITE Solar ET-NR48TBH440GL eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ELITE Solar ET-NR48TBH440GL rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)