FreeVolt ECP-PVGRAF-72HC-410W is a 410.0 W STC (379.7 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.47% efficiency, 49.4 V Voc at 25 C, and 53.95 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 379.7 W
- Voc @ 25C
- 49.4 V
- Efficiency
- 21.47%
How Does FreeVolt ECP-PVGRAF-72HC-410W Compare Against Peer CEC Listings?
How FreeVolt FreeVolt ECP-PVGRAF-72HC-410W handles rooftop heat (379.7 W PTC), 8 kW sizing, and cold winter string voltage.
FreeVolt builds the FreeVolt ECP-PVGRAF-72HC-410W (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 214.7 W/m2 (1.56 percentage points above 19.91% CEC median). Compared against Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W (410.0 W), this model holds strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Higher 49.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 16.52 A overcurrent floor served by a 20 A breaker.
Where Does FreeVolt ECP-PVGRAF-72HC-410W Fall Across Listed CEC Models?
Where FreeVolt ECP-PVGRAF-72HC-410W (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-72HC-410W?
Percentile placement of FreeVolt ECP-PVGRAF-72HC-410W across power density (214.7 W/m2), thermal retention, and nameplate STC wattage. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-72HC-410W?
Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-72HC-410W specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.47% Aperture Efficiency
Power density 214.7 W/m2 (1.56 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.95 V at -10 C (593.5 V string) and 55.25 V at -20 C (10 max).
20 Panels = 8,200 W STC
Occupies 38.2 m2 (411 sq ft) producing 7,594 W PTC; NEC 690.8 OCPD floor is 16.52 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.4 * (1 + (-0.263/100) * (-10 - 25)) = 53.95 V | OCPD = 1.56 * 10.59 = 16.52 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-72HC-410W: Voc=49.4 V, beta_Voc=-0.263%/C, Isc=10.59 A, STC=410.0 W, Area=1.91 m2.
Result: 11 panels max on 600 V (593.5 V); 20 panels for 8 kW (411 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-72HC-410W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-72HC-410W. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 379.7 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.7 V / 10.08 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.47% (1.91 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-72HC-410W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-72HC-410W (410.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 308 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 411 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 514 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?
All closely matched FreeVolt wattages and cosmetic trims sharing the FreeVolt ECP-PVGRAF-72HC-410W architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| FreeVolt ECP-PVGRAF-72HC-400W | 400.0 W | 370.2 W | 49.0 V | 40.3 V | 20.94% |
| FreeVolt ECP-PVGRAF-72HC-405W | 405.0 W | 375.0 W | 49.2 V | 40.5 V | 21.2% |
| FreeVolt ECP-PVGRAF-72HC-410W | 410.0 W | 379.7 W | 49.4 V | 40.7 V | 21.47% |
| FreeVolt ECP-PVGRAF-72HC-415W | 415.0 W | 384.5 W | 49.6 V | 40.9 V | 21.73% |
| FreeVolt ECP-PVGRAF-72HC-420W | 420.0 W | 389.3 W | 49.7 V | 41.0 V | 21.99% |
How Many FreeVolt ECP-PVGRAF-72HC-410W Modules Fit in a Cold-Weather String?
Maximum series module counts for FreeVolt ECP-PVGRAF-72HC-410W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.25 V | 10 panels | 552.5 V | 18 panels |
| -10 C (14 F) | 53.95 V | 11 panels | 593.5 V | 18 panels |
| 0 C (32 F) | 52.65 V | 11 panels | 579.1 V | 18 panels |
| 25 C (77 F STC) | 49.4 V | 12 panels | 592.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-72HC-410W?
Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-72HC-410W (410.0 W), including Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 49.4 V | 21.47% | 92.6% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.3% |
| AXITEC AC-410MB/144V AXITEC |
410.0 W | Tie (0 W) | 49.3 V | 21.03% | 93.0% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-72HC-410W?
Evaluate FreeVolt ECP-PVGRAF-72HC-410W (410.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-72HC-410W reaches 55.25 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 411 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (411 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-72HC-410W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-72HC-410W 8 kW Residential Fit
Needs 20 modules (411 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 379.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-72HC-410W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-72HC-410W?
Multiplying FreeVolt ECP-PVGRAF-72HC-410W's 10.59 A short-circuit current by 1.56 equals 16.52 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-72HC-410W before finalizing component orders.
Can FreeVolt ECP-PVGRAF-72HC-410W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.95 V cold Voc at 14 F and handles 10.59 A Isc; string inverters cap FreeVolt ECP-PVGRAF-72HC-410W at 11 panels on 600 V.
Is FreeVolt ECP-PVGRAF-72HC-410W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-72HC-410W rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)