Skip to main content
WireAndSun
Calculators
CEC PV Module

FreeVolt ECP-PVGRAF-72HC-410W — CEC Solar Module Specifications

Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt ECP-PVGRAF-72HC-410W is a 410.0 W STC (379.7 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.47% efficiency, 49.4 V Voc at 25 C, and 53.95 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
379.7 W
Voc @ 25C
49.4 V
Efficiency
21.47%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt ECP-PVGRAF-72HC-410W Compare Against Peer CEC Listings?

How FreeVolt FreeVolt ECP-PVGRAF-72HC-410W handles rooftop heat (379.7 W PTC), 8 kW sizing, and cold winter string voltage.

FreeVolt builds the FreeVolt ECP-PVGRAF-72HC-410W (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 214.7 W/m2 (1.56 percentage points above 19.91% CEC median). Compared against Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W (410.0 W), this model holds strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Higher 49.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 16.52 A overcurrent floor served by a 20 A breaker.

Where Does FreeVolt ECP-PVGRAF-72HC-410W Fall Across Listed CEC Models?

Where FreeVolt ECP-PVGRAF-72HC-410W (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt ECP-PVGRAF-72HC-410W (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt ECP-PVGRA: 410.0 W

What Dataset Percentiles Define FreeVolt ECP-PVGRAF-72HC-410W?

Percentile placement of FreeVolt ECP-PVGRAF-72HC-410W across power density (214.7 W/m2), thermal retention, and nameplate STC wattage. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

FreeVolt ECP-PVGRAF-72HC-410W Engineering BenchmarksPercentile comparison of FreeVolt ECP-PVGRAF-72HC-410W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention92.6%Module Efficiency21.47%

What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-72HC-410W?

Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-72HC-410W specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,599

21.47% Aperture Efficiency

Power density 214.7 W/m2 (1.56 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.95 V at -10 C (593.5 V string) and 55.25 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.2 m2 (411 sq ft) producing 7,594 W PTC; NEC 690.8 OCPD floor is 16.52 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.4 * (1 + (-0.263/100) * (-10 - 25)) = 53.95 V | OCPD = 1.56 * 10.59 = 16.52 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-72HC-410W: Voc=49.4 V, beta_Voc=-0.263%/C, Isc=10.59 A, STC=410.0 W, Area=1.91 m2.

Result: 11 panels max on 600 V (593.5 V); 20 panels for 8 kW (411 sq ft).

What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-72HC-410W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-72HC-410W. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-72HC-410W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 379.7 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.7 V / 10.08 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.47% (1.91 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt ECP-PVGRAF-72HC-410W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-72HC-410W (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 308 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 411 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 514 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?

All closely matched FreeVolt wattages and cosmetic trims sharing the FreeVolt ECP-PVGRAF-72HC-410W architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the FreeVolt ECP-PVGRAF-72HC-410W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
FreeVolt ECP-PVGRAF-72HC-400W 400.0 W 370.2 W 49.0 V 40.3 V 20.94%
FreeVolt ECP-PVGRAF-72HC-405W 405.0 W 375.0 W 49.2 V 40.5 V 21.2%
FreeVolt ECP-PVGRAF-72HC-410W 410.0 W 379.7 W 49.4 V 40.7 V 21.47%
FreeVolt ECP-PVGRAF-72HC-415W 415.0 W 384.5 W 49.6 V 40.9 V 21.73%
FreeVolt ECP-PVGRAF-72HC-420W 420.0 W 389.3 W 49.7 V 41.0 V 21.99%

How Many FreeVolt ECP-PVGRAF-72HC-410W Modules Fit in a Cold-Weather String?

Maximum series module counts for FreeVolt ECP-PVGRAF-72HC-410W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.4V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.25 V 10 panels 552.5 V 18 panels
-10 C (14 F) 53.95 V 11 panels 593.5 V 18 panels
0 C (32 F) 52.65 V 11 panels 579.1 V 18 panels
25 C (77 F STC) 49.4 V 12 panels 592.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-72HC-410W?

Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-72HC-410W (410.0 W), including Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 49.4 V 21.47% 92.6%
Auxin Solar AXNG1M410B
Auxin Solar
410.0 W Tie (0 W) 49.47 V 20.92% 93.4%
Auxin Solar AXNG1M410W
Auxin Solar
410.0 W Tie (0 W) 49.47 V 20.92% 93.3%
AXITEC AC-410MB/144V
AXITEC
410.0 W Tie (0 W) 49.3 V 21.03% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-72HC-410W?

Evaluate FreeVolt ECP-PVGRAF-72HC-410W (410.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-72HC-410W reaches 55.25 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 411 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (411 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-72HC-410W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt ECP-PVGRAF-72HC-410W 8 kW Residential Fit

Needs 20 modules (411 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 379.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-72HC-410W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-72HC-410W?

Multiplying FreeVolt ECP-PVGRAF-72HC-410W's 10.59 A short-circuit current by 1.56 equals 16.52 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-72HC-410W before finalizing component orders.

Can FreeVolt ECP-PVGRAF-72HC-410W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.95 V cold Voc at 14 F and handles 10.59 A Isc; string inverters cap FreeVolt ECP-PVGRAF-72HC-410W at 11 panels on 600 V.

Is FreeVolt ECP-PVGRAF-72HC-410W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-72HC-410W rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.