Skip to main content
WireAndSun
Calculators
CEC PV Module

FreeVolt ECP-PVGRAF-144HC-440W — CEC Solar Module Specifications

Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt ECP-PVGRAF-144HC-440W is a 440.0 W STC (406.6 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.75% efficiency, 49.6 V Voc at 25 C, and 54.44 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
406.6 W
Voc @ 25C
49.6 V
Efficiency
20.75%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt ECP-PVGRAF-144HC-440W Compare Against Peer CEC Listings?

Engineering position of FreeVolt ECP-PVGRAF-144HC-440W (440.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, FreeVolt ECP-PVGRAF-144HC-440W pairs strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677) with 49.6 V nominal Voc. An 8 kW residential build (8,360 W DC, 7,725 W PTC) saves ~$2,092/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W offers a 440.0 W alternative.

Where Does FreeVolt ECP-PVGRAF-144HC-440W Fall Across Listed CEC Models?

Plots FreeVolt ECP-PVGRAF-144HC-440W at 440.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt ECP-PVGRAF-144HC-440W (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt ECP-PVGRA: 440.0 W

What Dataset Percentiles Define FreeVolt ECP-PVGRAF-144HC-440W?

Benchmarks FreeVolt ECP-PVGRAF-144HC-440W on STC wattage, thermal PTC/STC retention, and 20.75 aperture conversion efficiency against CEC peers.

FreeVolt ECP-PVGRAF-144HC-440W Engineering BenchmarksPercentile comparison of FreeVolt ECP-PVGRAF-144HC-440W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention92.4%Module Efficiency20.75%

What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-144HC-440W?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for FreeVolt ECP-PVGRAF-144HC-440W by FreeVolt.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,496

20.75% Aperture Efficiency

Power density 207.5 W/m2 (0.84 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.44 V at -10 C (598.8 V string) and 55.83 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 40.3 m2 (434 sq ft) producing 7,725 W PTC; NEC 690.8 OCPD floor is 17.67 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.6 * (1 + (-0.279/100) * (-10 - 25)) = 54.44 V | OCPD = 1.56 * 11.33 = 17.67 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-144HC-440W: Voc=49.6 V, beta_Voc=-0.279%/C, Isc=11.33 A, STC=440.0 W, Area=2.12 m2.

Result: 11 panels max on 600 V (598.8 V); 19 panels for 8 kW (434 sq ft).

What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-144HC-440W?

Laboratory test ratings recorded for FreeVolt ECP-PVGRAF-144HC-440W (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-144HC-440W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 406.6 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.33 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.0 V / 10.74 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.279 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.75% (2.12 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt ECP-PVGRAF-144HC-440W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (434 sq ft at 8 kW), and estimated Year-1 electric bill offset for FreeVolt ECP-PVGRAF-144HC-440W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 319 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 434 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 525 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?

Sibling wattage bins and frame colors grouped with FreeVolt ECP-PVGRAF-144HC-440W under FreeVolt to prevent duplicate spec pages. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the FreeVolt ECP-PVGRAF-144HC-440W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
FreeVolt ECP-PVGRAF-144HC-430W 430.0 W 397.0 W 49.2 V 40.6 V 20.28%
FreeVolt ECP-PVGRAF-144HC-435W 435.0 W 401.8 W 49.4 V 40.8 V 20.52%
FreeVolt ECP-PVGRAF-144HC-440W 440.0 W 406.6 W 49.6 V 41.0 V 20.75%
FreeVolt ECP-PVGRAF-144HC-445W 445.0 W 411.3 W 49.8 V 41.2 V 20.99%

How Many FreeVolt ECP-PVGRAF-144HC-440W Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for FreeVolt ECP-PVGRAF-144HC-440W (beta_Voc -0.279%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.6V and beta_Voc=-0.279%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.83 V 10 panels 558.3 V 17 panels
-10 C (14 F) 54.44 V 11 panels 598.8 V 18 panels
0 C (32 F) 53.06 V 11 panels 583.7 V 18 panels
25 C (77 F STC) 49.6 V 12 panels 595.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-144HC-440W?

Closest cross-brand CEC competitors to FreeVolt ECP-PVGRAF-144HC-440W matched near 440.0 W STC and 49.6 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
440.0 W Tie (0 W) 49.6 V 20.75% 92.4%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
440.0 W Tie (0 W) 49.3 V 20.56% 92.6%
Apollo Renewables Inc Apollo-M672BH-440TW
Apollo Renewables Inc
440.0 W Tie (0 W) 49.2 V 20.47% 93.4%
Bluesun Solar CoLtd BSM440M-72HPH
Bluesun Solar CoLtd
440.0 W Tie (0 W) 49.2 V 20.28% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-144HC-440W?

Evaluate FreeVolt ECP-PVGRAF-144HC-440W (440.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-144HC-440W reaches 55.83 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 434 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (434 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-144HC-440W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt ECP-PVGRAF-144HC-440W 8 kW Residential Fit

Needs 19 modules (434 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 406.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-144HC-440W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-144HC-440W?

Multiplying FreeVolt ECP-PVGRAF-144HC-440W's 11.33 A short-circuit current by 1.56 equals 17.67 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-144HC-440W before finalizing component orders.

Can FreeVolt ECP-PVGRAF-144HC-440W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.44 V cold Voc at 14 F and handles 11.33 A Isc; string inverters cap FreeVolt ECP-PVGRAF-144HC-440W at 11 panels on 600 V.

Is FreeVolt ECP-PVGRAF-144HC-440W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-144HC-440W rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.