FreeVolt ECP-PVGRAF-120HC-360W — CEC Solar Module Specifications

Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt ECP-PVGRAF-120HC-360W is a 360.0 W STC (332.2 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.89% efficiency, 40.5 V Voc at 25 C, and 44.45 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
332.2 W
Voc @ 25C
40.5 V
Efficiency
19.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt ECP-PVGRAF-120HC-360W Compare Against Peer CEC Listings?

Solar engineering breakdown for FreeVolt ECP-PVGRAF-120HC-360W: PTC thermal retention, roof footprint, and cold Voc string bounds. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Across 5,889 Mono-c-Si listings from FreeVolt and peers, FreeVolt ECP-PVGRAF-120HC-360W stands 50.0 W below the 410.0 W Mono-c-Si median and strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677). Sizing 6 kW (17 panels) to 10 kW (28 panels) yields $1,532-$2,523/yr in baseline US bill offset. Mid-range 40.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does FreeVolt ECP-PVGRAF-120HC-360W Fall Across Listed CEC Models?

Distribution marker showing FreeVolt ECP-PVGRAF-120HC-360W (360.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt ECP-PVGRAF-120HC-360W (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt ECP-PVGRA: 360.0 W

What Dataset Percentiles Define FreeVolt ECP-PVGRAF-120HC-360W?

Dataset percentiles tracking FreeVolt ECP-PVGRAF-120HC-360W power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

FreeVolt ECP-PVGRAF-120HC-360W Engineering BenchmarksPercentile comparison of FreeVolt ECP-PVGRAF-120HC-360W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention92.3%Module Efficiency19.89%

What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-120HC-360W?

Benchmark highlights for FreeVolt ECP-PVGRAF-120HC-360W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,917

19.89% Aperture Efficiency

Power density 198.9 W/m2 (0.02 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.45 V at -10 C (577.9 V string) and 45.58 V at -20 C (13 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 41.6 m2 (448 sq ft) producing 7,641 W PTC; NEC 690.8 OCPD floor is 17.71 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.5 * (1 + (-0.279/100) * (-10 - 25)) = 44.45 V | OCPD = 1.56 * 11.35 = 17.71 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-120HC-360W: Voc=40.5 V, beta_Voc=-0.279%/C, Isc=11.35 A, STC=360.0 W, Area=1.81 m2.

Result: 13 panels max on 600 V (577.9 V); 23 panels for 8 kW (448 sq ft).

What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-120HC-360W?

Official CEC datasheet figures for FreeVolt ECP-PVGRAF-120HC-360W (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-120HC-360W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 332.2 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.0 V / 10.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.279 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.89% (1.81 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt ECP-PVGRAF-120HC-360W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many FreeVolt ECP-PVGRAF-120HC-360W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 331 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 448 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 546 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?

Consolidated FreeVolt wattage variants sharing the FreeVolt ECP-PVGRAF-120HC-360W mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the FreeVolt ECP-PVGRAF-120HC-360W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
FreeVolt ECP-PVGRAF-120HC-350W 350.0 W 322.7 W 40.1 V 33.6 V 19.34%
FreeVolt ECP-PVGRAF-120HC-355W 355.0 W 327.5 W 40.3 V 33.8 V 19.61%
FreeVolt ECP-PVGRAF-120HC-360W 360.0 W 332.2 W 40.5 V 34.0 V 19.89%
FreeVolt ECP-PVGRAF-120HC-365W 365.0 W 337.0 W 40.7 V 34.2 V 20.17%
FreeVolt ECP-PVGRAF-120HC-370W 370.0 W 341.7 W 40.9 V 34.4 V 20.44%

How Many FreeVolt ECP-PVGRAF-120HC-360W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on FreeVolt ECP-PVGRAF-120HC-360W (44.45 V at 14 F). Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Computed from Voc=40.5V and beta_Voc=-0.279%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.58 V 13 panels 592.5 V 21 panels
-10 C (14 F) 44.45 V 13 panels 577.9 V 22 panels
0 C (32 F) 43.32 V 13 panels 563.2 V 23 panels
25 C (77 F STC) 40.5 V 14 panels 567.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-120HC-360W?

Competing CEC solar panels closest to FreeVolt ECP-PVGRAF-120HC-360W in nameplate wattage and Voc, starting with Apollo Renewables Inc Apollo-M660BH-360BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Apollo Renewables Inc Apollo-M660BH-360BB
Apollo Renewables Inc
360.0 W Tie (0 W) 40.5 V 20.0% 93.6%
AXITEC AC-360MH/120V
AXITEC
360.0 W Tie (0 W) 40.5 V 19.89% 92.3%
AXITEC AC-360MH/120VB
AXITEC
360.0 W Tie (0 W) 40.5 V 19.89% 93.3%
Dehui Solar Power (Vietnam) CoLtd DH-M760B 360W
Dehui Solar Power (Vietnam) CoLtd
360.0 W Tie (0 W) 40.5 V 19.67% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-120HC-360W?

Evaluate FreeVolt ECP-PVGRAF-120HC-360W (360.0 W STC, 40.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-120HC-360W reaches 45.58 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 448 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (448 sq ft).
  • 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-120HC-360W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt ECP-PVGRAF-120HC-360W 8 kW Residential Fit

Needs 23 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Apollo Renewables Inc Apollo-M660BH-360BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 332.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-120HC-360W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-120HC-360W?

Multiplying FreeVolt ECP-PVGRAF-120HC-360W's 11.35 A short-circuit current by 1.56 equals 17.71 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-120HC-360W before finalizing component orders.

Can FreeVolt ECP-PVGRAF-120HC-360W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.45 V cold Voc at 14 F and handles 11.35 A Isc; string inverters cap FreeVolt ECP-PVGRAF-120HC-360W at 13 panels on 600 V.

Is FreeVolt ECP-PVGRAF-120HC-360W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-120HC-360W rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.