Skip to main content
WireAndSun
Calculators
CEC PV Module

FreeVolt ECP-PVGRAF-120HC-360W Black — CEC Solar Module Specifications

Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt ECP-PVGRAF-120HC-360W Black is a 360.0 W STC (335.9 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.67% efficiency, 40.5 V Voc at 25 C, and 44.48 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
335.9 W
Voc @ 25C
40.5 V
Efficiency
19.67%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt ECP-PVGRAF-120HC-360W Black Compare Against Peer CEC Listings?

How FreeVolt FreeVolt ECP-PVGRAF-120HC-360W Black handles rooftop heat (335.9 W PTC), 8 kW sizing, and cold winter string voltage.

FreeVolt builds the FreeVolt ECP-PVGRAF-120HC-360W Black (Mono-c-Si) as a compact residential or specialty off-grid module delivering 196.7 W/m2 (0.24 percentage points below 19.91% CEC median). Compared against Apollo Renewables Inc Apollo-M660BH-360BB (360.0 W), this model holds strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Mid-range 40.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 17.71 A overcurrent floor served by a 20 A breaker.

Where Does FreeVolt ECP-PVGRAF-120HC-360W Black Fall Across Listed CEC Models?

Where FreeVolt ECP-PVGRAF-120HC-360W Black (360.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt ECP-PVGRAF-120HC-360W Black (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt ECP-PVGRA: 360.0 W

What Dataset Percentiles Define FreeVolt ECP-PVGRAF-120HC-360W Black?

Percentile placement of FreeVolt ECP-PVGRAF-120HC-360W Black across power density (196.7 W/m2), thermal retention, and nameplate STC wattage.

FreeVolt ECP-PVGRAF-120HC-360W Black Engineering BenchmarksPercentile comparison of FreeVolt ECP-PVGRAF-120HC-360W Black wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention93.3%Module Efficiency19.67%

What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-120HC-360W Black?

Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-120HC-360W Black specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,599

19.67% Aperture Efficiency

Power density 196.7 W/m2 (0.24 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.48 V at -10 C (578.2 V string) and 45.62 V at -20 C (13 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 42.1 m2 (453 sq ft) producing 7,726 W PTC; NEC 690.8 OCPD floor is 17.71 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.5 * (1 + (-0.281/100) * (-10 - 25)) = 44.48 V | OCPD = 1.56 * 11.35 = 17.71 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-120HC-360W Black: Voc=40.5 V, beta_Voc=-0.281%/C, Isc=11.35 A, STC=360.0 W, Area=1.83 m2.

Result: 13 panels max on 600 V (578.2 V); 23 panels for 8 kW (453 sq ft).

What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-120HC-360W Black?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-120HC-360W Black.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-120HC-360W Black.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 335.9 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.0 V / 10.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.281 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.67% (1.83 m2) Array roof footprint density
Cell Count & Technology 40 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt ECP-PVGRAF-120HC-360W Black Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-120HC-360W Black (360.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 335 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 453 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 552 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?

All closely matched FreeVolt wattages and cosmetic trims sharing the FreeVolt ECP-PVGRAF-120HC-360W Black architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the FreeVolt ECP-PVGRAF-120HC-360W Black wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
FreeVolt ECP-PVGRAF-120HC-350W Black 350.0 W 326.3 W 40.1 V 33.6 V 19.13%
FreeVolt ECP-PVGRAF-120HC-355W Black 355.0 W 331.1 W 40.3 V 33.8 V 19.4%
FreeVolt ECP-PVGRAF-120HC-360W Black 360.0 W 335.9 W 40.5 V 34.0 V 19.67%
FreeVolt ECP-PVGRAF-120HC-365W Black 365.0 W 340.7 W 40.7 V 34.2 V 19.95%
FreeVolt ECP-PVGRAF-120HC-370W Black 370.0 W 345.5 W 40.9 V 34.4 V 20.22%

How Many FreeVolt ECP-PVGRAF-120HC-360W Black Modules Fit in a Cold-Weather String?

Maximum series module counts for FreeVolt ECP-PVGRAF-120HC-360W Black from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.5V and beta_Voc=-0.281%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.62 V 13 panels 593.1 V 21 panels
-10 C (14 F) 44.48 V 13 panels 578.2 V 22 panels
0 C (32 F) 43.35 V 13 panels 563.6 V 23 panels
25 C (77 F STC) 40.5 V 14 panels 567.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-120HC-360W Black?

Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-120HC-360W Black (360.0 W), including Apollo Renewables Inc Apollo-M660BH-360BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Apollo Renewables Inc Apollo-M660BH-360BB
Apollo Renewables Inc
360.0 W Tie (0 W) 40.5 V 20.0% 93.6%
AXITEC AC-360MH/120V
AXITEC
360.0 W Tie (0 W) 40.5 V 19.89% 92.3%
AXITEC AC-360MH/120VB
AXITEC
360.0 W Tie (0 W) 40.5 V 19.89% 93.3%
Dehui Solar Power (Vietnam) CoLtd DH-M760B 360W
Dehui Solar Power (Vietnam) CoLtd
360.0 W Tie (0 W) 40.5 V 19.67% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-120HC-360W Black?

Evaluate FreeVolt ECP-PVGRAF-120HC-360W Black (360.0 W STC, 40.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-120HC-360W Black reaches 45.62 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 453 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (453 sq ft).
  • 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-120HC-360W Black carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt ECP-PVGRAF-120HC-360W Black 8 kW Residential Fit

Needs 23 modules (453 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Apollo Renewables Inc Apollo-M660BH-360BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 335.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-120HC-360W Black by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-120HC-360W Black?

Multiplying FreeVolt ECP-PVGRAF-120HC-360W Black's 11.35 A short-circuit current by 1.56 equals 17.71 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can FreeVolt ECP-PVGRAF-120HC-360W Black pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.48 V cold Voc at 14 F and handles 11.35 A Isc; string inverters cap FreeVolt ECP-PVGRAF-120HC-360W Black at 13 panels on 600 V.

Is FreeVolt ECP-PVGRAF-120HC-360W Black eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-120HC-360W Black rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.