FreeVolt ECP-PVGRAF-120BHC-360W is a 360.0 W STC (333.1 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 20.22% efficiency, 40.5 V Voc at 25 C, and 44.92 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 333.1 W
- Voc @ 25C
- 40.5 V
- Efficiency
- 20.22%
How Does FreeVolt ECP-PVGRAF-120BHC-360W Compare Against Peer CEC Listings?
How FreeVolt FreeVolt ECP-PVGRAF-120BHC-360W handles rooftop heat (333.1 W PTC), 8 kW sizing, and cold winter string voltage.
FreeVolt builds the FreeVolt ECP-PVGRAF-120BHC-360W (Mono-c-Si) as a compact residential or specialty off-grid module delivering 202.2 W/m2 (0.31 percentage points above 19.91% CEC median). Compared against Apollo Renewables Inc Apollo-M660BH-360BB (360.0 W), this model holds strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677). Mid-range 40.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 17.67 A overcurrent floor served by a 20 A breaker.
Where Does FreeVolt ECP-PVGRAF-120BHC-360W Fall Across Listed CEC Models?
Where FreeVolt ECP-PVGRAF-120BHC-360W (360.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-120BHC-360W?
Percentile placement of FreeVolt ECP-PVGRAF-120BHC-360W across power density (202.2 W/m2), thermal retention, and nameplate STC wattage. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-120BHC-360W?
Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-120BHC-360W specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.22% Aperture Efficiency
Power density 202.2 W/m2 (0.31 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.92 V at -10 C (584.0 V string) and 46.19 V at -20 C (12 max).
23 Panels = 8,280 W STC
Occupies 40.9 m2 (441 sq ft) producing 7,661 W PTC; NEC 690.8 OCPD floor is 17.67 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.5 * (1 + (-0.312/100) * (-10 - 25)) = 44.92 V | OCPD = 1.56 * 11.33 = 17.67 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-120BHC-360W: Voc=40.5 V, beta_Voc=-0.312%/C, Isc=11.33 A, STC=360.0 W, Area=1.78 m2.
Result: 13 panels max on 600 V (584.0 V); 23 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-120BHC-360W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-120BHC-360W. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 333.1 W (92.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.9 V / 10.62 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.312 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.22% (1.78 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-120BHC-360W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-120BHC-360W (360.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 326 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 441 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 536 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?
All closely matched FreeVolt wattages and cosmetic trims sharing the FreeVolt ECP-PVGRAF-120BHC-360W architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| FreeVolt ECP-PVGRAF-120BHC-350W | 350.0 W | 323.6 W | 40.1 V | 33.5 V | 19.66% |
| FreeVolt ECP-PVGRAF-120BHC-355W | 355.0 W | 328.4 W | 40.3 V | 33.7 V | 19.94% |
| FreeVolt ECP-PVGRAF-120BHC-360W | 360.0 W | 333.1 W | 40.5 V | 33.9 V | 20.22% |
| FreeVolt ECP-PVGRAF-120BHC-365W | 365.0 W | 337.9 W | 40.7 V | 34.1 V | 20.51% |
| FreeVolt ECP-PVGRAF-120BHC-370W | 370.0 W | 342.6 W | 40.9 V | 34.3 V | 20.79% |
How Many FreeVolt ECP-PVGRAF-120BHC-360W Modules Fit in a Cold-Weather String?
Maximum series module counts for FreeVolt ECP-PVGRAF-120BHC-360W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.19 V | 12 panels | 554.3 V | 21 panels |
| -10 C (14 F) | 44.92 V | 13 panels | 584.0 V | 22 panels |
| 0 C (32 F) | 43.66 V | 13 panels | 567.6 V | 22 panels |
| 25 C (77 F STC) | 40.5 V | 14 panels | 567.0 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-120BHC-360W?
Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-120BHC-360W (360.0 W), including Apollo Renewables Inc Apollo-M660BH-360BB. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M660BH-360BB Apollo Renewables Inc |
360.0 W | Tie (0 W) | 40.5 V | 20.0% | 93.6% |
| AXITEC AC-360MH/120V AXITEC |
360.0 W | Tie (0 W) | 40.5 V | 19.89% | 92.3% |
| AXITEC AC-360MH/120VB AXITEC |
360.0 W | Tie (0 W) | 40.5 V | 19.89% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M760B 360W Dehui Solar Power (Vietnam) CoLtd |
360.0 W | Tie (0 W) | 40.5 V | 19.67% | 93.3% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-120BHC-360W?
Evaluate FreeVolt ECP-PVGRAF-120BHC-360W (360.0 W STC, 40.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-120BHC-360W reaches 46.19 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 441 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (441 sq ft).
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-120BHC-360W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-120BHC-360W 8 kW Residential Fit
Needs 23 modules (441 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Apollo Renewables Inc Apollo-M660BH-360BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 333.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-120BHC-360W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-120BHC-360W?
Multiplying FreeVolt ECP-PVGRAF-120BHC-360W's 11.33 A short-circuit current by 1.56 equals 17.67 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-120BHC-360W before finalizing component orders.
Can FreeVolt ECP-PVGRAF-120BHC-360W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.92 V cold Voc at 14 F and handles 11.33 A Isc; string inverters cap FreeVolt ECP-PVGRAF-120BHC-360W at 13 panels on 600 V.
Is FreeVolt ECP-PVGRAF-120BHC-360W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-120BHC-360W rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)