Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: STP20000TL-US-10 {480V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: STP20000TL-US-10 {480V} outputs 20,000 W AC at 480 V, 3-phase (24.1 A continuous, 35 A OCPD), ranking #478 of 2,343 CEC inverters at 97.68% efficiency with a 380-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
20,000 W
AC Voltage
480 V, 3-phase
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
97.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: STP20000TL-US-10 {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for SMA America: STP20000TL-US-10 {480V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Ranking #631 of 2,343 CEC inverters (top 27.2%; higher than 72.8% of peers), SMA America: STP20000TL-US-10 {480V} is a grid-tied PV inverter delivering 20,000 W continuous AC at 480 V, 3-phase (24.1 A continuous). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 97.68% (-0.34 pts vs the 98.02% 480 V median) against peers like Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} (20,000 W).

Where Does SMA America: STP20000TL-US-10 {480V} Fall Across Listed CEC Models?

Marks SMA America: STP20000TL-US-10 {480V} (20,000 W AC) across the California Energy Commission inverter AC capacity distribution. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: STP20000TL-US-10 {480V} (20,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: STP20: 20,000 W

What Dataset Percentiles Define SMA America: STP20000TL-US-10 {480V}?

Benchmarks SMA America: STP20000TL-US-10 {480V} continuous AC output, 97.68% CEC weighted efficiency, and 35 A OCPD breaker demand.

SMA America: STP20000TL-US-10 {480V} Technical ThresholdsPercentile comparison for SMA America: STP20000TL-US-10 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output20,000 WCEC Efficiency97.68%Backfeed Breaker35 A

What Do the Dataset Ranks Show for SMA America: STP20000TL-US-10 {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining SMA America: STP20000TL-US-10 {480V} by SMA America. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Eff #478 / 2,343

97.68% CEC Weighted Efficiency

-0.34 pts vs the 98.02% 480 V median; overall power rank #631 (20,000 W, top 27.2%; higher than 72.8% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 24.1 A = 30.1 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

380 V - 800 V (Max 800 V DC)

Tracking span of 420.0 V; listed since 2019-02-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 20000.0W / 480 V 3-phase -> 24.1 A | Breaker >= 1.25 * 24.1 = 30.1 A -> 35 A

CEC Inverters.csv for SMA America: STP20000TL-US-10 {480V}: Paco=20000.0 W, Vac=480 V, Vdcmax=800.0 V, Eff=97.68%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: STP20000TL-US-10 {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: STP20000TL-US-10 {480V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for SMA America: STP20000TL-US-10 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 20,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 380 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 29.4605 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.68% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2019-02-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to SMA America: STP20000TL-US-10 {480V} (480 V, 3-phase)?

Evaluates SMA America: STP20000TL-US-10 {480V} (35 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SMA America: STP20000TL-US-10 {480V} (35 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 35 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (480V) 80 A 35 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 35 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 35 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 35 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: STP20000TL-US-10 {480V}?

Sample PV string lengths aligned within 380-800 V MPPT and 800 V DC max at -10 C. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sampled CEC PV modules aligned within 380.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 9 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 12 to 18 panels 7.92 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 12 to 17 panels 7.22 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 14 to 19 panels 3.8 kW

Which Competing Grid-Support Inverters Compare to SMA America: STP20000TL-US-10 {480V}?

Competing CEC grid-support inverters near 20,000 W AC and 480 V, 3-phase, led by Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}
Chint Power Systems America
20,000 W Tie (0 W) 480.0 V 850.0 V 97.86%
Fronius International GmbH: Fronius Symo 200-3 480 {480V}
Fronius International GmbH
20,000 W Tie (0 W) 480.0 V 800.0 V 97.72%
Fronius International GmbH: Fronius Symo Advanced 200-3 480 {480V}
Fronius International GmbH
20,227 W +227 W 480.0 V 800.0 V 97.69%
Fronius International GmbH: Fronius Symo Advanced 200-3 480 Lite {480V}
Fronius International GmbH
20,227 W +227 W 480.0 V 800.0 V 97.69%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: STP20000TL-US-10 {480V}?

Check SMA America: STP20000TL-US-10 {480V} (20,000 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on SMA America: STP20000TL-US-10 {480V}.

SMA America: STP20000TL-US-10 {480V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.68%) and MPPT window (380-800 V) directly against Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} (20,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: STP20000TL-US-10 {480V} by SMA America covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does SMA America: STP20000TL-US-10 {480V} require?

At 20,000 W continuous AC (480 V, 3-phase), continuous current is 24.1 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: STP20000TL-US-10 {480V} require?

At 20,000 W AC and 480 V, 3-phase, continuous line current is 24.1 A, requiring a 35 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does SMA America: STP20000TL-US-10 {480V} compare to Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}?

SMA America: STP20000TL-US-10 {480V} delivers 20,000 W AC at 97.68% CEC efficiency with a 800 V DC ceiling, while Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} outputs 20,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.