Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} — CEC Inverter Specifications

Manufacturer: Chint Power Systems America Registry: CEC Verified Engineering Specification

Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} outputs 20,000 W AC at 480 V, 3-phase (24.1 A continuous, 35 A OCPD), ranking #404 of 2,343 CEC inverters at 97.86% efficiency with a 560-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
20,000 W
AC Voltage
480 V, 3-phase
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
97.86%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}.

Rated at 20,000 W AC (24.1 A continuous), Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} ranks #404 of 2,343 CEC units at 97.86% efficiency (-0.16 pts vs the 98.02% 480 V median). Minimum 75 C copper conductor sizing for its 35 A circuit is 8 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 850 V DC at record local winter lows.

Where Does Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} Fall Across Listed CEC Models?

Marks Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} (20,000 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} (20,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACChint Power System: 20,000 W

What Dataset Percentiles Define Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}?

Benchmarks Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} continuous AC output, 97.86% CEC weighted efficiency, and 35 A OCPD breaker demand.

Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} Technical ThresholdsPercentile comparison for Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output20,000 WCEC Efficiency97.86%Backfeed Breaker35 A

What Do the Dataset Ranks Show for Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} by Chint Power Systems America.

Eff #404 / 2,343

97.86% CEC Weighted Efficiency

-0.16 pts vs the 98.02% 480 V median; overall power rank #631 (20,000 W, top 27.2%; higher than 72.8% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 24.1 A = 30.1 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

560 V - 850 V (Max 850 V DC)

Tracking span of 290.0 V; listed since 2022-06-13 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 20000.0W / 480 V 3-phase -> 24.1 A | Breaker >= 1.25 * 24.1 = 30.1 A -> 35 A

CEC Inverters.csv for Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}: Paco=20000.0 W, Vac=480 V, Vdcmax=850.0 V, Eff=97.86%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}.

Official California Energy Commission (NREL SAM) test parameters for Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 20,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 850 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 560 V - 850 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 27.806 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.86% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2022-06-13 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} (480 V, 3-phase)?

Evaluates Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} (35 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} (35 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 35 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (480V) 80 A 35 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 35 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 35 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 35 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}?

Sample PV string lengths aligned within 560-850 V MPPT and 850 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 560.0-850.0 V MPPT and 850.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 14 to 15 panels 8.85 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 17 to 20 panels 8.8 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 17 to 18 panels 7.65 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 20 panels (fixed) 4.0 kW

Which Competing Grid-Support Inverters Compare to Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}?

Competing CEC grid-support inverters near 20,000 W AC and 480 V, 3-phase, led by Fronius International GmbH: Fronius Symo 200-3 480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Fronius International GmbH: Fronius Symo 200-3 480 {480V}
Fronius International GmbH
20,000 W Tie (0 W) 480.0 V 800.0 V 97.72%
Fronius International GmbH: Fronius Symo Advanced 200-3 480 {480V}
Fronius International GmbH
20,227 W +227 W 480.0 V 800.0 V 97.69%
Fronius International GmbH: Fronius Symo Advanced 200-3 480 Lite {480V}
Fronius International GmbH
20,227 W +227 W 480.0 V 800.0 V 97.69%
Fronius International GmbH: Fronius Symo 175-3 480 {480V}
Fronius International GmbH
17,500 W -2500 W 480.0 V 800.0 V 97.77%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}?

Check Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} (20,000 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}.

Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.86%) and MPPT window (560-850 V) directly against Fronius International GmbH: Fronius Symo 200-3 480 {480V} (20,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} by Chint Power Systems America covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} require?

At 20,000 W continuous AC (480 V, 3-phase), continuous current is 24.1 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} require?

At 20,000 W AC and 480 V, 3-phase, continuous line current is 24.1 A, requiring a 35 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} compare to Fronius International GmbH: Fronius Symo 200-3 480 {480V}?

Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} delivers 20,000 W AC at 97.86% CEC efficiency with a 850 V DC ceiling, while Fronius International GmbH: Fronius Symo 200-3 480 {480V} outputs 20,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.