Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: STP 50-US-41 {480V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: STP 50-US-41 {480V} outputs 50,000 W AC at 480 V, 3-phase (60.1 A continuous, 80 A OCPD), ranking #576 of 2,343 CEC inverters at 97.43% efficiency with a 500-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
50,000 W
AC Voltage
480 V, 3-phase
Min PV Breaker
80 A (4 AWG Cu)
CEC Efficiency
97.43%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: STP 50-US-41 {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for SMA America: STP 50-US-41 {480V}.

Rated at 50,000 W AC (60.1 A continuous), SMA America: STP 50-US-41 {480V} ranks #576 of 2,343 CEC units at 97.43% efficiency (-0.59 pts vs the 98.02% 480 V median). Minimum 75 C copper conductor sizing for its 80 A circuit is 4 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 800 V DC at record local winter lows.

Where Does SMA America: STP 50-US-41 {480V} Fall Across Listed CEC Models?

Marks SMA America: STP 50-US-41 {480V} (50,000 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: STP 50-US-41 {480V} (50,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: STP 5: 50,000 W

What Dataset Percentiles Define SMA America: STP 50-US-41 {480V}?

Benchmarks SMA America: STP 50-US-41 {480V} continuous AC output, 97.43% CEC weighted efficiency, and 80 A OCPD breaker demand.

SMA America: STP 50-US-41 {480V} Technical ThresholdsPercentile comparison for SMA America: STP 50-US-41 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output50,000 WCEC Efficiency97.43%Backfeed Breaker80 A

What Do the Dataset Ranks Show for SMA America: STP 50-US-41 {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining SMA America: STP 50-US-41 {480V} by SMA America.

Eff #576 / 2,343

97.43% CEC Weighted Efficiency

-0.59 pts vs the 98.02% 480 V median; overall power rank #438 (50,000 W, top 19.3%; higher than 80.7% of peers).

NEC 705.12 Check

80 A Required Backfeed OCPD

125% x 60.1 A = 75.1 A -> 80 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

500 V - 800 V (Max 800 V DC)

Tracking span of 300.0 V; listed since 2022-11-01 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 50000.0W / 480 V 3-phase -> 60.1 A | Breaker >= 1.25 * 60.1 = 75.1 A -> 80 A

CEC Inverters.csv for SMA America: STP 50-US-41 {480V}: Paco=50000.0 W, Vac=480 V, Vdcmax=800.0 V, Eff=97.43%.

Result: Min 80 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: STP 50-US-41 {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: STP 50-US-41 {480V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: STP 50-US-41 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 50,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 500 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 70.7829 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.43% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2022-11-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to SMA America: STP 50-US-41 {480V} (480 V, 3-phase)?

Evaluates SMA America: STP 50-US-41 {480V} (80 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SMA America: STP 50-US-41 {480V} (80 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 80 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 80 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 80 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 80 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 80 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: STP 50-US-41 {480V}?

Sample PV string lengths aligned within 500-800 V MPPT and 800 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 500.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 12 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 15 to 18 panels 7.92 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 15 to 17 panels 7.22 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 18 to 19 panels 3.8 kW

Which Competing Grid-Support Inverters Compare to SMA America: STP 50-US-41 {480V}?

Competing CEC grid-support inverters near 50,000 W AC and 480 V, 3-phase, led by ABB: TRIO-500-TL-OUTD-US-480 {480V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: TRIO-500-TL-OUTD-US-480 {480V}
ABB
50,000 W Tie (0 W) 480.0 V 800.0 V 98.27%
Canadian Solar Inc: CSI-50KTL-CT {480V}
Canadian Solar Inc
50,000 W Tie (0 W) 480.0 V 850.0 V 98.36%
Canadian Solar Inc: CSI-50KTL-GS {480V}
Canadian Solar Inc
50,000 W Tie (0 W) 480.0 V 720.0 V 98.43%
Canadian Solar Inc: CSI-50KTL-GS-FL {480V}
Canadian Solar Inc
50,000 W Tie (0 W) 480.0 V 720.0 V 98.47%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: STP 50-US-41 {480V}?

Check SMA America: STP 50-US-41 {480V} (50,000 W AC, 80 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on SMA America: STP 50-US-41 {480V}.

SMA America: STP 50-US-41 {480V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on an 80 A OCPD breaker (60.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.43%) and MPPT window (500-800 V) directly against ABB: TRIO-500-TL-OUTD-US-480 {480V} (50,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: STP 50-US-41 {480V} by SMA America covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does SMA America: STP 50-US-41 {480V} require?

At 50,000 W continuous AC (480 V, 3-phase), continuous current is 60.1 A; 125% NEC 690.8/705.12 sizing requires an 80 A breaker and 4 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: STP 50-US-41 {480V} require?

At 50,000 W AC and 480 V, 3-phase, continuous line current is 60.1 A, requiring an 80 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does SMA America: STP 50-US-41 {480V} compare to ABB: TRIO-500-TL-OUTD-US-480 {480V}?

SMA America: STP 50-US-41 {480V} delivers 50,000 W AC at 97.43% CEC efficiency with a 800 V DC ceiling, while ABB: TRIO-500-TL-OUTD-US-480 {480V} outputs 50,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.