SMA America: STP 13-US-50 {208V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: STP 13-US-50 {208V} outputs 13,000 W AC at 208 V, 3-phase (36.1 A continuous, 50 A OCPD), ranking #2,025 of 2,343 CEC inverters at 95.92% efficiency with a 230-640 V MPPT window and 640 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
13,000 W
AC Voltage
208 V, 3-phase
Min PV Breaker
50 A (8 AWG Cu)
CEC Efficiency
95.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: STP 13-US-50 {208V} Compare Against Peer CEC Listings?

How SMA America SMA America: STP 13-US-50 {208V} compares on 95.92% efficiency, MPPT span, and 120% busbar interconnection.

SMA America certifies SMA America: STP 13-US-50 {208V} (grid-tied PV inverter, active in CEC directory) at 13,000 W AC (8,000 W above the 5,000 W 208 V median). Its 640 V DC ceiling pairs with an MPPT window of 230-640 V (span 410.0 V). Under NEC 690.8/705.12, 125% sizing demands 8 AWG Cu conductors on a 50 A OCPD.

Where Does SMA America: STP 13-US-50 {208V} Fall Across Listed CEC Models?

Position of SMA America: STP 13-US-50 {208V} (13,000 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: STP 13-US-50 {208V} (13,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: STP 1: 13,000 W

What Dataset Percentiles Define SMA America: STP 13-US-50 {208V}?

Percentile placement of SMA America: STP 13-US-50 {208V} across AC power class, conversion efficiency, and backfeed breaker size.

SMA America: STP 13-US-50 {208V} Technical ThresholdsPercentile comparison for SMA America: STP 13-US-50 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output13,000 WCEC Efficiency95.92%Backfeed Breaker50 A

What Do the Dataset Ranks Show for SMA America: STP 13-US-50 {208V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for SMA America: STP 13-US-50 {208V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Eff #2,025 / 2,343

95.92% CEC Weighted Efficiency

-0.49 pts vs the 96.41% 208 V median; overall power rank #694 (13,000 W, top 29.7%; higher than 70.3% of peers).

NEC 705.12 Check

50 A Required Backfeed OCPD

125% x 36.1 A = 45.1 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

230 V - 640 V (Max 640 V DC)

Tracking span of 410.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 13000.0W / 208 V 3-phase -> 36.1 A | Breaker >= 1.25 * 36.1 = 45.1 A -> 50 A

CEC Inverters.csv for SMA America: STP 13-US-50 {208V}: Paco=13000.0 W, Vac=208 V, Vdcmax=640.0 V, Eff=95.92%.

Result: Min 50 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: STP 13-US-50 {208V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for SMA America: STP 13-US-50 {208V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: STP 13-US-50 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 13,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 640 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 230 V - 640 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 40.4572 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.92% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: STP 13-US-50 {208V} (208 V, 3-phase)?

Check whether SMA America: STP 13-US-50 {208V} (50 A breaker) fits without main breaker derate or supply-side taps.

Evaluates SMA America: STP 13-US-50 {208V} (50 A required OCPD at 208 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 50 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 50 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 50 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 50 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 50 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: STP 13-US-50 {208V}?

Verified cold-weather (-10 C) series module counts matched to SMA America: STP 13-US-50 {208V}'s 640 V DC ceiling.

Sampled CEC PV modules aligned within 230.0-640.0 V MPPT and 640.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 11 panels 6.49 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 7 to 15 panels 6.6 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 7 to 14 panels 5.95 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 8 to 15 panels 3.0 kW

Which Competing Grid-Support Inverters Compare to SMA America: STP 13-US-50 {208V}?

Alternative CEC inverters comparable to SMA America: STP 13-US-50 {208V}, including EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W) at 208 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}
EG4 Electronics LLC
13,899 W +899 W 208.0 V 440.0 V 96.46%
Chint Power Systems America: CPS ECH12KTL/US {208V}
Chint Power Systems America
12,000 W -1000 W 208.0 V 480.0 V 96.63%
EcoFlow Inc: EF-PCS-24 {208V 115kW}
EcoFlow Inc
11,444 W -1556 W 208.0 V 480.0 V 96.52%
Chint Power Systems America: CPS ECH114KTL/US {208V}
Chint Power Systems America
11,350 W -1650 W 208.0 V 480.0 V 96.63%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: STP 13-US-50 {208V}?

Check SMA America: STP 13-US-50 {208V} (13,000 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 640 V DC on SMA America: STP 13-US-50 {208V}.

SMA America: STP 13-US-50 {208V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (36.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.92%) and MPPT window (230-640 V) directly against EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: STP 13-US-50 {208V} by SMA America covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

What breaker and wire size does SMA America: STP 13-US-50 {208V} require?

At 13,000 W continuous AC (208 V, 3-phase), continuous current is 36.1 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: STP 13-US-50 {208V} require?

At 13,000 W AC and 208 V, 3-phase, continuous line current is 36.1 A, requiring a 50 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does SMA America: STP 13-US-50 {208V} compare to EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}?

SMA America: STP 13-US-50 {208V} delivers 13,000 W AC at 95.92% CEC efficiency with a 640 V DC ceiling, while EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} outputs 13,899 W at 208 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.