Manufacturer: Chint Power Systems America Registry: CEC Verified Engineering Specification

Chint Power Systems America: CPS ECH114KTL/US {208V} outputs 11,350 W AC at 208 V, commercial single-phase (54.6 A continuous, 70 A OCPD), ranking #1,325 of 2,343 CEC inverters at 96.63% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
11,350 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
70 A (4 AWG Cu)
CEC Efficiency
96.63%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Chint Power Systems America: CPS ECH114KTL/US {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,325), 200-480 V MPPT tracking, and panel fit for Chint Power Systems America: CPS ECH114KTL/US {208V}.

Chint Power Systems America: CPS ECH114KTL/US {208V} from Chint Power Systems America outputs 54.6 A continuous AC at 208 V, commercial single-phase (11,350 W AC, rank #799). Paired with 4 AWG Cu conductors and a 70 A OCPD, its 96.63% CEC efficiency compares closely with EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V} (11,325 W). Keep NEC 690.7 winter string Voc below 480 V DC.

Where Does Chint Power Systems America: CPS ECH114KTL/US {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Chint Power Systems America: CPS ECH114KTL/US {208V} at 11,350 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Chint Power Systems America: CPS ECH114KTL/US {208V} (11,350 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACChint Power System: 11,350 W

What Dataset Percentiles Define Chint Power Systems America: CPS ECH114KTL/US {208V}?

Dataset percentiles comparing Chint Power Systems America: CPS ECH114KTL/US {208V} against 2,343 certified grid-support inverters nationwide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Chint Power Systems America: CPS ECH114KTL/US {208V} Technical ThresholdsPercentile comparison for Chint Power Systems America: CPS ECH114KTL/US {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output11,350 WCEC Efficiency96.63%Backfeed Breaker70 A

What Do the Dataset Ranks Show for Chint Power Systems America: CPS ECH114KTL/US {208V}?

Engineering highlights for Chint Power Systems America: CPS ECH114KTL/US {208V} covering efficiency, 4 AWG Cu feeder, and panel compatibility.

Eff #1,325 / 2,343

96.63% CEC Weighted Efficiency

+0.22 pts vs the 96.41% 208 V median; overall power rank #799 (11,350 W, top 34.1%; higher than 65.9% of peers).

NEC 705.12 Check

70 A Required Backfeed OCPD

125% x 54.6 A = 68.2 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2025-04-21 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11350.0W / 208 V -> 54.6 A | Breaker >= 1.25 * 54.6 = 68.2 A -> 70 A

CEC Inverters.csv for Chint Power Systems America: CPS ECH114KTL/US {208V}: Paco=11350.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=96.63%.

Result: Min 70 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Chint Power Systems America: CPS ECH114KTL/US {208V}?

California Energy Commission Solar Equipment List parameters for Chint Power Systems America: CPS ECH114KTL/US {208V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Chint Power Systems America: CPS ECH114KTL/US {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 11,350 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 31.7442 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.63% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-04-21 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

What Switchgear Limits Apply to Chint Power Systems America: CPS ECH114KTL/US {208V} (208 V, commercial single-phase)?

Panelboard and switchgear backfeed allowances for Chint Power Systems America: CPS ECH114KTL/US {208V} (70 A OCPD). Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Evaluates Chint Power Systems America: CPS ECH114KTL/US {208V} (70 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 70 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 70 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 70 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 70 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 70 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Chint Power Systems America: CPS ECH114KTL/US {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Chint Power Systems America: CPS ECH114KTL/US {208V}.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Chint Power Systems America: CPS ECH114KTL/US {208V}?

Four alternative CEC inverters matched to Chint Power Systems America: CPS ECH114KTL/US {208V} (11,350 W AC), led by EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V}
EG4 Electronics LLC
11,325 W -25 W 208.0 V 440.0 V 96.79%
EcoFlow Inc: EF-PCS-24 {208V 115kW}
EcoFlow Inc
11,444 W +94 W 208.0 V 480.0 V 96.52%
EG4 Electronics LLC: 18KPV-12LV {208V}
EG4 Electronics LLC
10,499 W -851 W 208.0 V 480.0 V 96.07%
Delta Electronics: S12_BDI {208V}
Delta Electronics
10,057 W -1293 W 208.0 V 480.0 V 96.7%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Chint Power Systems America: CPS ECH114KTL/US {208V}?

Check Chint Power Systems America: CPS ECH114KTL/US {208V} (11,350 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Chint Power Systems America: CPS ECH114KTL/US {208V}.

Chint Power Systems America: CPS ECH114KTL/US {208V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (54.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.63%) and MPPT window (200-480 V) directly against EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V} (11,325 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Chint Power Systems America: CPS ECH114KTL/US {208V} by Chint Power Systems America covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Chint Power Systems America: CPS ECH114KTL/US {208V} require?

At 11,350 W continuous AC (208 V, commercial single-phase), continuous current is 54.6 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Chint Power Systems America: CPS ECH114KTL/US {208V} require?

At 11,350 W AC and 208 V, commercial single-phase, continuous line current is 54.6 A, requiring a 70 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Chint Power Systems America: CPS ECH114KTL/US {208V} compare to EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V}?

Chint Power Systems America: CPS ECH114KTL/US {208V} delivers 11,350 W AC at 96.63% CEC efficiency with a 480 V DC ceiling, while EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V} outputs 11,325 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.