Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: SHP FLEX-US-21 {660V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SHP FLEX-US-21 {660V} outputs 172,810 W AC at 660 V, 3-phase (151.2 A continuous, 200 A OCPD), ranking #60 of 2,343 CEC inverters at 98.57% efficiency with a 968-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
172,810 W
AC Voltage
660 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
98.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SHP FLEX-US-21 {660V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 660 V, 3-phase grid-support overview for SMA America: SHP FLEX-US-21 {660V}.

Ranking #260 of 2,343 CEC inverters (top 11.1%; higher than 88.9% of peers), SMA America: SHP FLEX-US-21 {660V} is a grid-tied PV inverter delivering 172,810 W continuous AC at 660 V, 3-phase (151.2 A continuous). Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.57% (+0.36 pts vs the 98.21% 660 V median) against peers like KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} (151,228 W).

Where Does SMA America: SHP FLEX-US-21 {660V} Fall Across Listed CEC Models?

Marks SMA America: SHP FLEX-US-21 {660V} (172,810 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SHP FLEX-US-21 {660V} (172,810 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SHP F: 172,810 W

What Dataset Percentiles Define SMA America: SHP FLEX-US-21 {660V}?

Benchmarks SMA America: SHP FLEX-US-21 {660V} continuous AC output, 98.57% CEC weighted efficiency, and 200 A OCPD breaker demand.

SMA America: SHP FLEX-US-21 {660V} Technical ThresholdsPercentile comparison for SMA America: SHP FLEX-US-21 {660V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output172,810 WCEC Efficiency98.57%Backfeed Breaker200 A

What Do the Dataset Ranks Show for SMA America: SHP FLEX-US-21 {660V}?

Four key NEC 705.12 and California Energy Commission metrics defining SMA America: SHP FLEX-US-21 {660V} by SMA America.

Eff #60 / 2,343

98.57% CEC Weighted Efficiency

+0.36 pts vs the 98.21% 660 V median; overall power rank #260 (172,810 W, top 11.1%; higher than 88.9% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 151.2 A = 189.0 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

968 V - 1,200 V (Max 1,200 V DC)

Tracking span of 232.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 660 V, 3-phase switchgear (200A Bus / 200A Main (660V) to 1,200A Bus / 1,200A Main (660V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 172810.0W / 660 V 3-phase -> 151.2 A | Breaker >= 1.25 * 151.2 = 189.0 A -> 200 A

CEC Inverters.csv for SMA America: SHP FLEX-US-21 {660V}: Paco=172810.0 W, Vac=660 V, Vdcmax=1200.0 V, Eff=98.57%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (660V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: SHP FLEX-US-21 {660V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: SHP FLEX-US-21 {660V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP FLEX-US-21 {660V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 172,810 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 660 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 968 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 160.995 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.57% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: SHP FLEX-US-21 {660V} (660 V, 3-phase)?

Evaluates SMA America: SHP FLEX-US-21 {660V} (200 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SMA America: SHP FLEX-US-21 {660V} (200 A required OCPD at 660 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (660V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (660V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (660V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (660V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (660V) 240 A 200 A PASS (120% Commercial Busbar)

Which Competing Grid-Support Inverters Compare to SMA America: SHP FLEX-US-21 {660V}?

Competing CEC grid-support inverters near 172,810 W AC and 660 V, 3-phase, led by KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}
KACO new energy GmbH
151,228 W -21582 W 660.0 V 1300.0 V 98.78%
KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQX {660V}
KACO new energy GmbH
151,228 W -21582 W 660.0 V 1300.0 V 98.78%
EPC Power Corp: 50-200100 {660V}
EPC Power Corp
515,072 W +342262 W 660.0 V 1500.0 V 98.47%
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1715TL U B660 {660V}
INGETEAM POWER TECHNOLOGY SA
1,390,614 W +1217804 W 660.0 V 1200.0 V 97.22%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP FLEX-US-21 {660V}?

Check SMA America: SHP FLEX-US-21 {660V} (172,810 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SHP FLEX-US-21 {660V}.

SMA America: SHP FLEX-US-21 {660V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (151.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.57%) and MPPT window (968-1,200 V) directly against KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} (151,228 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP FLEX-US-21 {660V} by SMA America covering breaker sizing, MPPT limits, and 660 V, 3-phase interconnection.

What breaker and wire size does SMA America: SHP FLEX-US-21 {660V} require?

At 172,810 W continuous AC (660 V, 3-phase), continuous current is 151.2 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SHP FLEX-US-21 {660V} require?

At 172,810 W AC and 660 V, 3-phase, continuous line current is 151.2 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (660V) or NEC 705.11 interconnection.

How does SMA America: SHP FLEX-US-21 {660V} compare to KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}?

SMA America: SHP FLEX-US-21 {660V} delivers 172,810 W AC at 98.57% CEC efficiency with a 1,200 V DC ceiling, while KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} outputs 151,228 W at 660 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.