SMA America: SHP FLEX-US-21 {660V} outputs 172,810 W AC at 660 V, 3-phase (151.2 A continuous, 200 A OCPD), ranking #60 of 2,343 CEC inverters at 98.57% efficiency with a 968-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 172,810 W
- AC Voltage
- 660 V, 3-phase
- Min PV Breaker
- 200 A (3/0 AWG Cu)
- CEC Efficiency
- 98.57%
How Does SMA America: SHP FLEX-US-21 {660V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 660 V, 3-phase grid-support overview for SMA America: SHP FLEX-US-21 {660V}.
Ranking #260 of 2,343 CEC inverters (top 11.1%; higher than 88.9% of peers), SMA America: SHP FLEX-US-21 {660V} is a grid-tied PV inverter delivering 172,810 W continuous AC at 660 V, 3-phase (151.2 A continuous). Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.57% (+0.36 pts vs the 98.21% 660 V median) against peers like KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} (151,228 W).
Where Does SMA America: SHP FLEX-US-21 {660V} Fall Across Listed CEC Models?
Marks SMA America: SHP FLEX-US-21 {660V} (172,810 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define SMA America: SHP FLEX-US-21 {660V}?
Benchmarks SMA America: SHP FLEX-US-21 {660V} continuous AC output, 98.57% CEC weighted efficiency, and 200 A OCPD breaker demand.
What Do the Dataset Ranks Show for SMA America: SHP FLEX-US-21 {660V}?
Four key NEC 705.12 and California Energy Commission metrics defining SMA America: SHP FLEX-US-21 {660V} by SMA America.
98.57% CEC Weighted Efficiency
+0.36 pts vs the 98.21% 660 V median; overall power rank #260 (172,810 W, top 11.1%; higher than 88.9% of peers).
200 A Required Backfeed OCPD
125% x 151.2 A = 189.0 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).
968 V - 1,200 V (Max 1,200 V DC)
Tracking span of 232.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 660 V, 3-phase switchgear (200A Bus / 200A Main (660V) to 1,200A Bus / 1,200A Main (660V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 172810.0W / 660 V 3-phase -> 151.2 A | Breaker >= 1.25 * 151.2 = 189.0 A -> 200 A
CEC Inverters.csv for SMA America: SHP FLEX-US-21 {660V}: Paco=172810.0 W, Vac=660 V, Vdcmax=1200.0 V, Eff=98.57%.
Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (660V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for SMA America: SHP FLEX-US-21 {660V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: SHP FLEX-US-21 {660V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 172,810 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 660 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 968 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 160.995 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.57% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to SMA America: SHP FLEX-US-21 {660V} (660 V, 3-phase)?
Evaluates SMA America: SHP FLEX-US-21 {660V} (200 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (660V) | 40 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (660V) | 80 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (660V) | 120 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (660V) | 160 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (660V) | 240 A | 200 A | PASS (120% Commercial Busbar) |
Which Competing Grid-Support Inverters Compare to SMA America: SHP FLEX-US-21 {660V}?
Competing CEC grid-support inverters near 172,810 W AC and 660 V, 3-phase, led by KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} KACO new energy GmbH |
151,228 W | -21582 W | 660.0 V | 1300.0 V | 98.78% |
| KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQX {660V} KACO new energy GmbH |
151,228 W | -21582 W | 660.0 V | 1300.0 V | 98.78% |
| EPC Power Corp: 50-200100 {660V} EPC Power Corp |
515,072 W | +342262 W | 660.0 V | 1500.0 V | 98.47% |
| INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1715TL U B660 {660V} INGETEAM POWER TECHNOLOGY SA |
1,390,614 W | +1217804 W | 660.0 V | 1200.0 V | 97.22% |
What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP FLEX-US-21 {660V}?
Check SMA America: SHP FLEX-US-21 {660V} (172,810 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SHP FLEX-US-21 {660V}.
SMA America: SHP FLEX-US-21 {660V} Panel & Wire Spec
Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (151.2 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.57%) and MPPT window (968-1,200 V) directly against KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} (151,228 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SMA America: SHP FLEX-US-21 {660V} by SMA America covering breaker sizing, MPPT limits, and 660 V, 3-phase interconnection.
What breaker and wire size does SMA America: SHP FLEX-US-21 {660V} require?
At 172,810 W continuous AC (660 V, 3-phase), continuous current is 151.2 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does SMA America: SHP FLEX-US-21 {660V} require?
At 172,810 W AC and 660 V, 3-phase, continuous line current is 151.2 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (660V) or NEC 705.11 interconnection.
How does SMA America: SHP FLEX-US-21 {660V} compare to KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}?
SMA America: SHP FLEX-US-21 {660V} delivers 172,810 W AC at 98.57% CEC efficiency with a 1,200 V DC ceiling, while KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} outputs 151,228 W at 660 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)