SMA America: SHP FLEX-US-21 {600V} outputs 150,079 W AC at 600 V, 3-phase (144.4 A continuous, 200 A OCPD), ranking #67 of 2,343 CEC inverters at 98.52% efficiency with a 880-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
150,079 W
AC Voltage
600 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
98.52%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SHP FLEX-US-21 {600V} Compare Against Peer CEC Listings?

Breaker sizing (200 A), 3/0 AWG Cu wire rules, and DC input limits for SMA America: SHP FLEX-US-21 {600V}.

For NEC 705.12 solar interconnection, SMA America: SHP FLEX-US-21 {600V} outputs 144.4 A continuous AC at 600 V, 3-phase and needs a 200 A backfeed breaker on 3/0 AWG Cu (75 C). Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap. Conversion efficiency scores 98.52% (#67 of 2,343, +1.70 pts vs overall CEC median).

Where Does SMA America: SHP FLEX-US-21 {600V} Fall Across Listed CEC Models?

Output power comparison showing where SMA America: SHP FLEX-US-21 {600V} sits among all 2,343 CEC-listed grid-support inverters. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SHP FLEX-US-21 {600V} (150,079 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SHP F: 150,079 W

What Dataset Percentiles Define SMA America: SHP FLEX-US-21 {600V}?

Relative ranking of SMA America: SHP FLEX-US-21 {600V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

SMA America: SHP FLEX-US-21 {600V} Technical ThresholdsPercentile comparison for SMA America: SHP FLEX-US-21 {600V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output150,079 WCEC Efficiency98.52%Backfeed Breaker200 A

What Do the Dataset Ranks Show for SMA America: SHP FLEX-US-21 {600V}?

Snapshot of SMA America: SHP FLEX-US-21 {600V} efficiency rank (#67), OCPD breaker size, MPPT span, and busbar verdict.

Eff #67 / 2,343

98.52% CEC Weighted Efficiency

+0.24 pts vs the 98.28% 600 V median; overall power rank #271 (150,079 W, top 11.6%; higher than 88.4% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 144.4 A = 180.5 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

880 V - 1,200 V (Max 1,200 V DC)

Tracking span of 320.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 150079.0W / 600 V 3-phase -> 144.4 A | Breaker >= 1.25 * 144.4 = 180.5 A -> 200 A

CEC Inverters.csv for SMA America: SHP FLEX-US-21 {600V}: Paco=150079.0 W, Vac=600 V, Vdcmax=1200.0 V, Eff=98.52%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (600V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: SHP FLEX-US-21 {600V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SMA America: SHP FLEX-US-21 {600V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP FLEX-US-21 {600V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 150,079 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 600 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 880 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 158.674 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.52% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: SHP FLEX-US-21 {600V} (600 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for SMA America: SHP FLEX-US-21 {600V} at 600 V, 3-phase.

Evaluates SMA America: SHP FLEX-US-21 {600V} (200 A required OCPD at 600 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (600V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (600V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (600V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (600V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (600V) 240 A 200 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: SHP FLEX-US-21 {600V}?

Minimum and maximum series solar module strings fitting SMA America: SHP FLEX-US-21 {600V} MPPT and 1,200 V limits.

Sampled CEC PV modules aligned within 880.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 21 panels (fixed) 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 27 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 26 panels (fixed) 11.05 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 22 panels (fixed) 11.33 kW

Which Competing Grid-Support Inverters Compare to SMA America: SHP FLEX-US-21 {600V}?

Peer 600 V, 3-phase CEC inverters near 150,079 W AC output such as Xiamen Kehua Digital Energy Tech Co Ltd: BCS150K-B-HM-US X2 {600V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Xiamen Kehua Digital Energy Tech Co Ltd: BCS150K-B-HM-US X2 {600V}
Xiamen Kehua Digital Energy Tech Co Ltd
150,015 W -64 W 600.0 V 1450.0 V 98.35%
Yaskawa Solectria Solar: XGI 1500-150/166-UL {600V}
Yaskawa Solectria Solar
150,000 W -79 W 600.0 V 1250.0 V 98.48%
Yaskawa Solectria Solar: XGI 1500-150/166-UL-A {600V}
Yaskawa Solectria Solar
150,000 W -79 W 600.0 V 1250.0 V 98.48%
LS Energy Solutions LLC: PBE-6140-R61-1A0-1000 {600V}
LS Energy Solutions LLC
139,449 W -10630 W 600.0 V 1350.0 V 98.27%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP FLEX-US-21 {600V}?

Check SMA America: SHP FLEX-US-21 {600V} (150,079 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SHP FLEX-US-21 {600V}.

SMA America: SHP FLEX-US-21 {600V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (144.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.52%) and MPPT window (880-1,200 V) directly against Xiamen Kehua Digital Energy Tech Co Ltd: BCS150K-B-HM-US X2 {600V} (150,015 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP FLEX-US-21 {600V} by SMA America covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.

What breaker and wire size does SMA America: SHP FLEX-US-21 {600V} require?

At 150,079 W continuous AC (600 V, 3-phase), continuous current is 144.4 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SHP FLEX-US-21 {600V} require?

At 150,079 W AC and 600 V, 3-phase, continuous line current is 144.4 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.

How does SMA America: SHP FLEX-US-21 {600V} compare to Xiamen Kehua Digital Energy Tech Co Ltd: BCS150K-B-HM-US X2 {600V}?

SMA America: SHP FLEX-US-21 {600V} delivers 150,079 W AC at 98.52% CEC efficiency with a 1,200 V DC ceiling, while Xiamen Kehua Digital Energy Tech Co Ltd: BCS150K-B-HM-US X2 {600V} outputs 150,015 W at 600 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.