Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: SHP FLEX-US-21 {208V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SHP FLEX-US-21 {208V} outputs 55,076 W AC at 208 V, 3-phase (152.9 A continuous, 200 A OCPD), ranking #1,808 of 2,343 CEC inverters at 96.26% efficiency with a 372-1,195 V MPPT window and 1,195 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
55,076 W
AC Voltage
208 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
96.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SHP FLEX-US-21 {208V} Compare Against Peer CEC Listings?

Breaker sizing (200 A), 3/0 AWG Cu wire rules, and DC input limits for SMA America: SHP FLEX-US-21 {208V}.

Classified as a grid-tied PV inverter (listed since 2025-01-02), SMA America: SHP FLEX-US-21 {208V} requires 191.1 A design capacity -> 200 A breaker using 3/0 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 96.26% (-0.56 pts vs overall CEC median) across 2,343 CEC models, while commercial 208 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (208v) or nec 705.11 supply-side tap.

Where Does SMA America: SHP FLEX-US-21 {208V} Fall Across Listed CEC Models?

Output power comparison showing where SMA America: SHP FLEX-US-21 {208V} sits among all 2,343 CEC-listed grid-support inverters. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SHP FLEX-US-21 {208V} (55,076 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SHP F: 55,076 W

What Dataset Percentiles Define SMA America: SHP FLEX-US-21 {208V}?

Relative ranking of SMA America: SHP FLEX-US-21 {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

SMA America: SHP FLEX-US-21 {208V} Technical ThresholdsPercentile comparison for SMA America: SHP FLEX-US-21 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output55,076 WCEC Efficiency96.26%Backfeed Breaker200 A

What Do the Dataset Ranks Show for SMA America: SHP FLEX-US-21 {208V}?

Snapshot of SMA America: SHP FLEX-US-21 {208V} efficiency rank (#1,808), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,808 / 2,343

96.26% CEC Weighted Efficiency

-0.15 pts vs the 96.41% 208 V median; overall power rank #432 (55,076 W, top 18.4%; higher than 81.6% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 152.9 A = 191.1 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

372 V - 1,195 V (Max 1,195 V DC)

Tracking span of 823.0 V; listed since 2025-01-02 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 55076.0W / 208 V 3-phase -> 152.9 A | Breaker >= 1.25 * 152.9 = 191.1 A -> 200 A

CEC Inverters.csv for SMA America: SHP FLEX-US-21 {208V}: Paco=55076.0 W, Vac=208 V, Vdcmax=1195.0 V, Eff=96.26%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: SHP FLEX-US-21 {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SMA America: SHP FLEX-US-21 {208V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP FLEX-US-21 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 55,076 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,195 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 372 V - 1,195 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 98.1407 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.26% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-01-02 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to SMA America: SHP FLEX-US-21 {208V} (208 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for SMA America: SHP FLEX-US-21 {208V} at 208 V, 3-phase.

Evaluates SMA America: SHP FLEX-US-21 {208V} (200 A required OCPD at 208 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (208V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (208V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (208V) 240 A 200 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: SHP FLEX-US-21 {208V}?

Minimum and maximum series solar module strings fitting SMA America: SHP FLEX-US-21 {208V} MPPT and 1,195 V limits.

Sampled CEC PV modules aligned within 372.0-1195.0 V MPPT and 1195.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 9 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 12 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 11 to 26 panels 11.05 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 13 to 29 panels 5.8 kW

Which Competing Grid-Support Inverters Compare to SMA America: SHP FLEX-US-21 {208V}?

Peer 208 V, 3-phase CEC inverters near 55,076 W AC output such as Chint Power Systems America: SCA50K-T-US-208 {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: SCA50K-T-US-208 {208V}
Chint Power Systems America
50,000 W -5076 W 208.0 V 700.0 V 95.93%
CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}
CSI Solar Co Ltd
29,878 W -25198 W 208.0 V 680.0 V 96.38%
Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}
Chint Power Systems America
25,000 W -30076 W 208.0 V 850.0 V 96.26%
EcoFlow Inc: EF-PCS-24 {208V 24kW}
EcoFlow Inc
24,291 W -30785 W 208.0 V 480.0 V 96.01%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP FLEX-US-21 {208V}?

Check SMA America: SHP FLEX-US-21 {208V} (55,076 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,195 V DC on SMA America: SHP FLEX-US-21 {208V}.

SMA America: SHP FLEX-US-21 {208V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (152.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.26%) and MPPT window (372-1,195 V) directly against Chint Power Systems America: SCA50K-T-US-208 {208V} (50,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP FLEX-US-21 {208V} by SMA America covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

What breaker and wire size does SMA America: SHP FLEX-US-21 {208V} require?

At 55,076 W continuous AC (208 V, 3-phase), continuous current is 152.9 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SHP FLEX-US-21 {208V} require?

At 55,076 W AC and 208 V, 3-phase, continuous line current is 152.9 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does SMA America: SHP FLEX-US-21 {208V} compare to Chint Power Systems America: SCA50K-T-US-208 {208V}?

SMA America: SHP FLEX-US-21 {208V} delivers 55,076 W AC at 96.26% CEC efficiency with a 1,195 V DC ceiling, while Chint Power Systems America: SCA50K-T-US-208 {208V} outputs 50,000 W at 208 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.