Manufacturer: Chint Power Systems America Registry: CEC Verified Engineering Specification

Chint Power Systems America: SCA50K-T-US-208 {208V} outputs 50,000 W AC at 208 V, 3-phase (138.8 A continuous, 175 A OCPD), ranking #2,021 of 2,343 CEC inverters at 95.93% efficiency with a 200-700 V MPPT window and 700 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
50,000 W
AC Voltage
208 V, 3-phase
Min PV Breaker
175 A (2/0 AWG Cu)
CEC Efficiency
95.93%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Chint Power Systems America: SCA50K-T-US-208 {208V} Compare Against Peer CEC Listings?

Breaker sizing (175 A), 2/0 AWG Cu wire rules, and DC input limits for Chint Power Systems America: SCA50K-T-US-208 {208V}.

For NEC 705.12 solar interconnection, Chint Power Systems America: SCA50K-T-US-208 {208V} outputs 138.8 A continuous AC at 208 V, 3-phase and needs a 175 A backfeed breaker on 2/0 AWG Cu (75 C). Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Conversion efficiency scores 95.93% (#2,021 of 2,343, -0.89 pts vs overall CEC median).

Where Does Chint Power Systems America: SCA50K-T-US-208 {208V} Fall Across Listed CEC Models?

Output power comparison showing where Chint Power Systems America: SCA50K-T-US-208 {208V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Chint Power Systems America: SCA50K-T-US-208 {208V} (50,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACChint Power System: 50,000 W

What Dataset Percentiles Define Chint Power Systems America: SCA50K-T-US-208 {208V}?

Relative ranking of Chint Power Systems America: SCA50K-T-US-208 {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Chint Power Systems America: SCA50K-T-US-208 {208V} Technical ThresholdsPercentile comparison for Chint Power Systems America: SCA50K-T-US-208 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output50,000 WCEC Efficiency95.93%Backfeed Breaker175 A

What Do the Dataset Ranks Show for Chint Power Systems America: SCA50K-T-US-208 {208V}?

Snapshot of Chint Power Systems America: SCA50K-T-US-208 {208V} efficiency rank (#2,021), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,021 / 2,343

95.93% CEC Weighted Efficiency

-0.48 pts vs the 96.41% 208 V median; overall power rank #438 (50,000 W, top 19.3%; higher than 80.7% of peers).

NEC 705.12 Check

175 A Required Backfeed OCPD

125% x 138.8 A = 173.5 A -> 175 A standard OCPD using 2/0 AWG Cu (75 C).

MPPT Window

200 V - 700 V (Max 700 V DC)

Tracking span of 500.0 V; listed since 2026-04-21 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 50000.0W / 208 V 3-phase -> 138.8 A | Breaker >= 1.25 * 138.8 = 173.5 A -> 175 A

CEC Inverters.csv for Chint Power Systems America: SCA50K-T-US-208 {208V}: Paco=50000.0 W, Vac=208 V, Vdcmax=700.0 V, Eff=95.93%.

Result: Min 175 A breaker & 2/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Chint Power Systems America: SCA50K-T-US-208 {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Chint Power Systems America: SCA50K-T-US-208 {208V}.

Official California Energy Commission (NREL SAM) test parameters for Chint Power Systems America: SCA50K-T-US-208 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 50,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 700 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 700 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 137.166 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.93% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2026-04-21 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Chint Power Systems America: SCA50K-T-US-208 {208V} (208 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Chint Power Systems America: SCA50K-T-US-208 {208V} at 208 V, 3-phase.

Evaluates Chint Power Systems America: SCA50K-T-US-208 {208V} (175 A required OCPD at 208 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (208V) 120 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (208V) 160 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (208V) 240 A 175 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Chint Power Systems America: SCA50K-T-US-208 {208V}?

Minimum and maximum series solar module strings fitting Chint Power Systems America: SCA50K-T-US-208 {208V} MPPT and 700 V limits.

Sampled CEC PV modules aligned within 200.0-700.0 V MPPT and 700.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 12 panels 7.08 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 16 panels 7.04 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 15 panels 6.38 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 17 panels 3.4 kW

Which Competing Grid-Support Inverters Compare to Chint Power Systems America: SCA50K-T-US-208 {208V}?

Peer 208 V, 3-phase CEC inverters near 50,000 W AC output such as CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}
CSI Solar Co Ltd
29,878 W -20122 W 208.0 V 680.0 V 96.38%
EcoFlow Inc: EF-PCS-24 {208V 24kW}
EcoFlow Inc
24,291 W -25709 W 208.0 V 480.0 V 96.01%
EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}
EG4 Electronics LLC
13,899 W -36101 W 208.0 V 440.0 V 96.46%
EcoFlow Inc: EF-PCS-24 {208V 115kW}
EcoFlow Inc
11,444 W -38556 W 208.0 V 480.0 V 96.52%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Chint Power Systems America: SCA50K-T-US-208 {208V}?

Check Chint Power Systems America: SCA50K-T-US-208 {208V} (50,000 W AC, 175 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 700 V DC on Chint Power Systems America: SCA50K-T-US-208 {208V}.

Chint Power Systems America: SCA50K-T-US-208 {208V} Panel & Wire Spec

Size 75 C copper conductors at 2/0 AWG Cu on a 175 A OCPD breaker (138.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.93%) and MPPT window (200-700 V) directly against CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} (29,878 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Chint Power Systems America: SCA50K-T-US-208 {208V} by Chint Power Systems America covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

What breaker and wire size does Chint Power Systems America: SCA50K-T-US-208 {208V} require?

At 50,000 W continuous AC (208 V, 3-phase), continuous current is 138.8 A; 125% NEC 690.8/705.12 sizing requires a 175 A breaker and 2/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Chint Power Systems America: SCA50K-T-US-208 {208V} require?

At 50,000 W AC and 208 V, 3-phase, continuous line current is 138.8 A, requiring a 175 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Chint Power Systems America: SCA50K-T-US-208 {208V} compare to CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}?

Chint Power Systems America: SCA50K-T-US-208 {208V} delivers 50,000 W AC at 95.93% CEC efficiency with a 700 V DC ceiling, while CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} outputs 29,878 W at 208 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.