Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: SHP 172-US-21 {660V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SHP 172-US-21 {660V} outputs 172,000 W AC at 660 V, 3-phase (150.5 A continuous, 200 A OCPD), ranking #60 of 2,343 CEC inverters at 98.57% efficiency with a 968-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
172,000 W
AC Voltage
660 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
98.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SHP 172-US-21 {660V} Compare Against Peer CEC Listings?

CEC efficiency rank (#60), 968-1,200 V MPPT tracking, and panel fit for SMA America: SHP 172-US-21 {660V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Operating at 660 V, 3-phase, SMA America: SHP 172-US-21 {660V} converts DC array energy at 98.57% CEC weighted efficiency (top 2.7%; higher than 97.3% of peers) with a 1,200 V max DC input and 160.235 A max input current for NEC 690.7 string safety. Compare this 172,000 W grid-tied PV inverter directly with KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} (151,228 W). Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap.

Where Does SMA America: SHP 172-US-21 {660V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SMA America: SHP 172-US-21 {660V} at 172,000 W continuous AC output. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SHP 172-US-21 {660V} (172,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SHP 1: 172,000 W

What Dataset Percentiles Define SMA America: SHP 172-US-21 {660V}?

Dataset percentiles comparing SMA America: SHP 172-US-21 {660V} against 2,343 certified grid-support inverters nationwide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

SMA America: SHP 172-US-21 {660V} Technical ThresholdsPercentile comparison for SMA America: SHP 172-US-21 {660V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output172,000 WCEC Efficiency98.57%Backfeed Breaker200 A

What Do the Dataset Ranks Show for SMA America: SHP 172-US-21 {660V}?

Engineering highlights for SMA America: SHP 172-US-21 {660V} covering efficiency, 3/0 AWG Cu feeder, and panel compatibility.

Eff #60 / 2,343

98.57% CEC Weighted Efficiency

+0.36 pts vs the 98.21% 660 V median; overall power rank #261 (172,000 W, top 11.1%; higher than 88.9% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 150.5 A = 188.1 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

968 V - 1,200 V (Max 1,200 V DC)

Tracking span of 232.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 660 V, 3-phase switchgear (200A Bus / 200A Main (660V) to 1,200A Bus / 1,200A Main (660V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 172000.0W / 660 V 3-phase -> 150.5 A | Breaker >= 1.25 * 150.5 = 188.1 A -> 200 A

CEC Inverters.csv for SMA America: SHP 172-US-21 {660V}: Paco=172000.0 W, Vac=660 V, Vdcmax=1200.0 V, Eff=98.57%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (660V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: SHP 172-US-21 {660V}?

California Energy Commission Solar Equipment List parameters for SMA America: SHP 172-US-21 {660V} (grid-tied PV inverter) interconnection. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP 172-US-21 {660V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 172,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 660 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 968 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 160.235 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.57% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: SHP 172-US-21 {660V} (660 V, 3-phase)?

Panelboard and switchgear backfeed allowances for SMA America: SHP 172-US-21 {660V} (200 A OCPD). Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Evaluates SMA America: SHP 172-US-21 {660V} (200 A required OCPD at 660 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (660V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (660V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (660V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (660V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (660V) 240 A 200 A PASS (120% Commercial Busbar)

Which Competing Grid-Support Inverters Compare to SMA America: SHP 172-US-21 {660V}?

Four alternative CEC inverters matched to SMA America: SHP 172-US-21 {660V} (172,000 W AC), led by KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}
KACO new energy GmbH
151,228 W -20772 W 660.0 V 1300.0 V 98.78%
KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQX {660V}
KACO new energy GmbH
151,228 W -20772 W 660.0 V 1300.0 V 98.78%
EPC Power Corp: 50-200100 {660V}
EPC Power Corp
515,072 W +343072 W 660.0 V 1500.0 V 98.47%
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1715TL U B660 {660V}
INGETEAM POWER TECHNOLOGY SA
1,390,614 W +1218614 W 660.0 V 1200.0 V 97.22%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP 172-US-21 {660V}?

Check SMA America: SHP 172-US-21 {660V} (172,000 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SHP 172-US-21 {660V}.

SMA America: SHP 172-US-21 {660V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (150.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.57%) and MPPT window (968-1,200 V) directly against KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} (151,228 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP 172-US-21 {660V} by SMA America covering breaker sizing, MPPT limits, and 660 V, 3-phase interconnection.

What breaker and wire size does SMA America: SHP 172-US-21 {660V} require?

At 172,000 W continuous AC (660 V, 3-phase), continuous current is 150.5 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SHP 172-US-21 {660V} require?

At 172,000 W AC and 660 V, 3-phase, continuous line current is 150.5 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (660V) or NEC 705.11 interconnection.

How does SMA America: SHP 172-US-21 {660V} compare to KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}?

SMA America: SHP 172-US-21 {660V} delivers 172,000 W AC at 98.57% CEC efficiency with a 1,200 V DC ceiling, while KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} outputs 151,228 W at 660 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.