SMA America: SBSE38-US-50 {240V} outputs 3,870 W AC at 240 V (16.1 A continuous, 25 A OCPD), ranking #630 of 2,343 CEC inverters at 97.38% efficiency with a 91-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 3,870 W
- AC Voltage
- 240 V
- Min PV Breaker
- 25 A (10 AWG Cu)
- CEC Efficiency
- 97.38%
How Does SMA America: SBSE38-US-50 {240V} Compare Against Peer CEC Listings?
How SMA America SMA America: SBSE38-US-50 {240V} compares on 97.38% efficiency, MPPT span, and 120% busbar interconnection. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
With a 91-480 V MPPT tracking band and 480 V DC ceiling, SMA America: SBSE38-US-50 {240V} handles 3,870 W continuous AC (1,906 W below the 5,776 W 240 V median). Requires a 25 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Installers comparing SMA America against Delta Electronics: E4-TL-US {240V} (3,870 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.
Where Does SMA America: SBSE38-US-50 {240V} Fall Across Listed CEC Models?
Position of SMA America: SBSE38-US-50 {240V} (3,870 W AC) relative to the 7,680 W CEC median inverter. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define SMA America: SBSE38-US-50 {240V}?
Percentile placement of SMA America: SBSE38-US-50 {240V} across AC power class, conversion efficiency, and backfeed breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Do the Dataset Ranks Show for SMA America: SBSE38-US-50 {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for SMA America: SBSE38-US-50 {240V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
97.38% CEC Weighted Efficiency
+0.70 pts vs the 96.68% 240 V median; overall power rank #1,633 (3,870 W, below CEC median; higher than 30.3% of peers).
25 A Required Backfeed OCPD
125% x 16.1 A = 20.1 A -> 25 A standard OCPD using 10 AWG Cu (75 C).
91 V - 480 V (Max 480 V DC)
Tracking span of 389.0 V; active in CEC directory (hybrid battery-capable inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 3869.9W / 240 V -> 16.1 A | Breaker >= 1.25 * 16.1 = 20.1 A -> 25 A
CEC Inverters.csv for SMA America: SBSE38-US-50 {240V}: Paco=3869.9 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.38%.
Result: Min 25 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for SMA America: SBSE38-US-50 {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for SMA America: SBSE38-US-50 {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 3,870 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 91 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 10.5417 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.38% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for SMA America: SBSE38-US-50 {240V}?
Check whether SMA America: SBSE38-US-50 {240V} (25 A breaker) fits without main breaker derate or supply-side taps. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 25 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 25 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 25 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 25 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 25 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With SMA America: SBSE38-US-50 {240V}?
Verified cold-weather (-10 C) series module counts matched to SMA America: SBSE38-US-50 {240V}'s 480 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 3 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 3 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 3 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 4 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to SMA America: SBSE38-US-50 {240V}?
Alternative CEC inverters comparable to SMA America: SBSE38-US-50 {240V}, including Delta Electronics: E4-TL-US {240V} (3,870 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: E4-TL-US {240V} Delta Electronics |
3,870 W | Tie (0 W) | 240.0 V | 400.0 V | 97.99% |
| Base Power Inc: MIN 3800TL-XH-US {240V} Base Power Inc |
3,888 W | +18 W | 240.0 V | 480.0 V | 97.51% |
| Delta Electronics: E4-TL-US(AC) {240V} Delta Electronics |
3,888 W | +18 W | 240.0 V | 480.0 V | 98.48% |
| Delta Electronics: E4_BDI {240V} Delta Electronics |
3,898 W | +28 W | 240.0 V | 480.0 V | 97.67% |
What Are the Interconnection Limits and Best-Fit Uses for SMA America: SBSE38-US-50 {240V}?
Check SMA America: SBSE38-US-50 {240V} (3,870 W AC, 25 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 25 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SMA America: SBSE38-US-50 {240V}.
SMA America: SBSE38-US-50 {240V} Panel & Wire Spec
Size 75 C copper conductors at 10 AWG Cu on a 25 A OCPD breaker (16.1 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.38%) and MPPT window (91-480 V) directly against Delta Electronics: E4-TL-US {240V} (3,870 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SMA America: SBSE38-US-50 {240V} by SMA America covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does SMA America: SBSE38-US-50 {240V} require?
At 3,870 W continuous AC (240 V), continuous current is 16.1 A; 125% NEC 690.8/705.12 sizing requires a 25 A breaker and 10 AWG Cu (75 C) wire.
Does SMA America: SBSE38-US-50 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 25 A at 240 V means PASS (120% Rule).
How does SMA America: SBSE38-US-50 {240V} compare to Delta Electronics: E4-TL-US {240V}?
SMA America: SBSE38-US-50 {240V} delivers 3,870 W AC at 97.38% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E4-TL-US {240V} outputs 3,870 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)