Base Power Inc: MIN 3800TL-XH-US {240V} outputs 3,888 W AC at 240 V (16.2 A continuous, 25 A OCPD), ranking #546 of 2,343 CEC inverters at 97.51% efficiency with a 160-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 3,888 W
- AC Voltage
- 240 V
- Min PV Breaker
- 25 A (10 AWG Cu)
- CEC Efficiency
- 97.51%
How Does Base Power Inc: MIN 3800TL-XH-US {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Base Power Inc: MIN 3800TL-XH-US {240V}.
Ranking #1,628 of 2,343 CEC inverters (below CEC median; higher than 30.4% of peers), Base Power Inc: MIN 3800TL-XH-US {240V} is a hybrid battery-capable inverter delivering 3,888 W continuous AC at 240 V (16.2 A continuous). Requires a 25 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Weighted CEC efficiency reaches 97.51% (+0.83 pts vs the 96.68% 240 V median) against peers like Delta Electronics: E4-TL-US(AC) {240V} (3,888 W).
Where Does Base Power Inc: MIN 3800TL-XH-US {240V} Fall Across Listed CEC Models?
Marks Base Power Inc: MIN 3800TL-XH-US {240V} (3,888 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define Base Power Inc: MIN 3800TL-XH-US {240V}?
Benchmarks Base Power Inc: MIN 3800TL-XH-US {240V} continuous AC output, 97.51% CEC weighted efficiency, and 25 A OCPD breaker demand.
What Do the Dataset Ranks Show for Base Power Inc: MIN 3800TL-XH-US {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining Base Power Inc: MIN 3800TL-XH-US {240V} by Base Power Inc.
97.51% CEC Weighted Efficiency
+0.83 pts vs the 96.68% 240 V median; overall power rank #1,628 (3,888 W, below CEC median; higher than 30.4% of peers).
25 A Required Backfeed OCPD
125% x 16.2 A = 20.2 A -> 25 A standard OCPD using 10 AWG Cu (75 C).
160 V - 480 V (Max 480 V DC)
Tracking span of 320.0 V; active in CEC directory (hybrid battery-capable inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 3888.0W / 240 V -> 16.2 A | Breaker >= 1.25 * 16.2 = 20.2 A -> 25 A
CEC Inverters.csv for Base Power Inc: MIN 3800TL-XH-US {240V}: Paco=3888.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.51%.
Result: Min 25 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Base Power Inc: MIN 3800TL-XH-US {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Base Power Inc: MIN 3800TL-XH-US {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 3,888 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 160 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 10.4925 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.51% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Base Power Inc: MIN 3800TL-XH-US {240V}?
Evaluates Base Power Inc: MIN 3800TL-XH-US {240V} (25 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 25 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 25 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 25 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 25 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 25 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Base Power Inc: MIN 3800TL-XH-US {240V}?
Sample PV string lengths aligned within 160-480 V MPPT and 480 V DC max at -10 C. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 4 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 5 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 5 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 6 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Base Power Inc: MIN 3800TL-XH-US {240V}?
Competing CEC grid-support inverters near 3,888 W AC and 240 V, led by Delta Electronics: E4-TL-US(AC) {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: E4-TL-US(AC) {240V} Delta Electronics |
3,888 W | Tie (0 W) | 240.0 V | 480.0 V | 98.48% |
| Delta Electronics: E4_BDI {240V} Delta Electronics |
3,898 W | +10 W | 240.0 V | 480.0 V | 97.67% |
| Delta Electronics: E4-TL-US {240V} Delta Electronics |
3,870 W | -18 W | 240.0 V | 400.0 V | 97.99% |
| Delta Electronics: M4-TL-US {240V} Delta Electronics |
3,840 W | -48 W | 240.0 V | 480.0 V | 97.59% |
What Are the Interconnection Limits and Best-Fit Uses for Base Power Inc: MIN 3800TL-XH-US {240V}?
Check Base Power Inc: MIN 3800TL-XH-US {240V} (3,888 W AC, 25 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 25 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Base Power Inc: MIN 3800TL-XH-US {240V}.
Base Power Inc: MIN 3800TL-XH-US {240V} Panel & Wire Spec
Size 75 C copper conductors at 10 AWG Cu on a 25 A OCPD breaker (16.2 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.51%) and MPPT window (160-480 V) directly against Delta Electronics: E4-TL-US(AC) {240V} (3,888 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Base Power Inc: MIN 3800TL-XH-US {240V} by Base Power Inc covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Base Power Inc: MIN 3800TL-XH-US {240V} require?
At 3,888 W continuous AC (240 V), continuous current is 16.2 A; 125% NEC 690.8/705.12 sizing requires a 25 A breaker and 10 AWG Cu (75 C) wire.
Does Base Power Inc: MIN 3800TL-XH-US {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 25 A at 240 V means PASS (120% Rule).
How does Base Power Inc: MIN 3800TL-XH-US {240V} compare to Delta Electronics: E4-TL-US(AC) {240V}?
Base Power Inc: MIN 3800TL-XH-US {240V} delivers 3,888 W AC at 97.51% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E4-TL-US(AC) {240V} outputs 3,888 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)