Skip to main content
WireAndSun
Calculators
CEC Brand Hub

G-Star Pte Ltd — CEC Certified Solar Equipment Catalog

Registry: California Energy Commission (CEC) Verified: 2026-11-26

G-Star Pte Ltd holds 66 verified California Energy Commission (CEC) certifications including 66 module series (365–740W PV). G-Star Pte Ltd carries 66 module series ranging from 365 W to 740 W STC (median 585 W vs 385 W CEC fleet median; 22.2% median aperture efficiency, cell architecture Mono-c-Si).

Manufacturer
G-Star Pte Ltd
PV Module Series
66
Listed Inverters
0
Output Range
365–740W PV
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Do G-Star Pte Ltd Solar Specifications Compare Across the CEC Catalog?

Technical overview of G-Star Pte Ltd solar certifications used by municipal inspectors and utilities to approve residential rooftop permits.

Independent third-party test metrics from the CEC confirm electrical ratings for G-Star Pte Ltd hardware under UL 1703/61730 and IEEE 1547 utility protocols. Typical PVUSA (PTC) real-world thermal output retains 95.1% of nameplate STC watts. G-Star Pte Ltd carries 66 module series ranging from 365 W to 740 W STC (median 585 W vs 385 W CEC fleet median; 22.2% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match G-Star Pte Ltd in our federal recall archive as of 2026.

Which G-Star Pte Ltd PV Module Series Are CEC Certified? (66)

Certified G-Star Pte Ltd PV module specifications below include exact variant counts so installers can match permitted plan sets to CEC datasheets.

Deduplicated CEC photovoltaic module series for G-Star Pte Ltd.
Module Series STC (W) PTC (W) Voc (V) Eff (%) Variants
G-Star Pte Ltd GSN8K66T(H)740WT 740.0 704.8 50.12 24.03 4
G-Star Pte Ltd GSD8K66T-735BT 735.0 700.4 49.93 23.86 4
G-Star Pte Ltd GSD8K66T-735WT 735.0 700.4 49.93 23.86 4
G-Star Pte Ltd GSN8K66T(H)735BT 735.0 699.9 49.93 23.86 4
G-Star Pte Ltd GSD8K66T-710BT 710.0 676.0 48.98 23.05 5
G-Star Pte Ltd GSD8K66T-710WT 710.0 676.0 48.98 23.05 5
G-Star Pte Ltd GSN8K66T(H)710BT 710.0 675.6 48.98 23.05 5
G-Star Pte Ltd GSN8K66T(H)710WT 710.0 675.6 48.98 23.05 5
G-Star Pte Ltd GSD8J66M-675BT 675.0 636.1 46.4 21.92 1
G-Star Pte Ltd GSD8J66M-675WT 675.0 636.1 46.4 21.92 1
G-Star Pte Ltd GSD8J66M-660BT 660.0 621.7 45.8 21.43 5
G-Star Pte Ltd GSD8J66M-660WT 660.0 621.7 45.8 21.43 5
G-Star Pte Ltd GSD7S78T-655BT 655.0 623.8 58.0 23.65 2
G-Star Pte Ltd GSD7S78T-655WT 655.0 623.8 58.0 23.65 2
G-Star Pte Ltd GSD8R66T-650BT 650.0 619.4 50.3 24.25 1
G-Star Pte Ltd GSD8R66T-650WT 650.0 619.4 50.3 24.25 1
G-Star Pte Ltd GSD7S78T-635BT 635.0 604.3 57.12 22.92 5
G-Star Pte Ltd GSD7S78T-635WT 635.0 604.3 57.12 22.92 5
G-Star Pte Ltd GSD8R66T-635BT 635.0 604.8 49.64 23.69 5
G-Star Pte Ltd GSD8R66T-635WT 635.0 604.8 49.64 23.69 5
G-Star Pte Ltd GSD7S78T-615BT 615.0 584.8 56.24 22.2 3
G-Star Pte Ltd GSD7S78T-615WT 615.0 584.8 56.24 22.2 3
G-Star Pte Ltd GSD8R66T-615BT 615.0 585.3 48.76 22.95 4
G-Star Pte Ltd GSD8R66T-615WT 615.0 585.3 48.76 22.95 4
G-Star Pte Ltd GSD7G78M-605BT 605.0 570.9 54.29 21.84 3
G-Star Pte Ltd GSD7G78M-605WT 605.0 570.9 54.29 21.84 3
G-Star Pte Ltd GSD7S72T-605BT 605.0 576.1 53.57 23.63 3
G-Star Pte Ltd GSD7S72T-605WT 605.0 576.1 53.57 23.63 3
G-Star Pte Ltd GSD8J60M-605BT 605.0 569.9 41.8 21.53 3
G-Star Pte Ltd GSD8J60M-605WT 605.0 569.9 41.8 21.53 3
G-Star Pte Ltd GSD8J60M-595BT 595.0 560.3 41.4 21.17 2
G-Star Pte Ltd GSD8J60M-595WT 595.0 560.3 41.4 21.17 2
G-Star Pte Ltd GSD7G78M-585BT 585.0 551.6 53.73 21.12 5
G-Star Pte Ltd GSD7G78M-585WT 585.0 551.6 53.73 21.12 5
G-Star Pte Ltd GSD7S72T-585BT 585.0 556.7 52.85 22.85 5
G-Star Pte Ltd GSD7S72T-585WT 585.0 556.7 52.85 22.85 5
G-Star Pte Ltd GSD7S72T-570BT 570.0 542.1 52.31 22.27 2
G-Star Pte Ltd GSD7S72T-570WT 570.0 542.1 52.31 22.27 2
G-Star Pte Ltd GSD7G72M-555BT 555.0 523.6 50.08 21.68 3
G-Star Pte Ltd GSD7G72M-555WT 555.0 523.6 50.08 21.68 3
G-Star Pte Ltd GSP7G72M(H)555WT 555.0 522.0 50.08 21.68 3
G-Star Pte Ltd GSD7G72M-540BT 540.0 509.1 49.6 21.09 4
G-Star Pte Ltd GSD7G72M-540WT 540.0 509.1 49.6 21.09 4
G-Star Pte Ltd GSP7G72M(H)535WT 535.0 502.7 49.46 20.9 5
G-Star Pte Ltd GSD8R48T-460BT 460.0 437.9 35.99 23.23 5
G-Star Pte Ltd GSD8R48T-460WT 460.0 437.9 35.99 23.23 5
G-Star Pte Ltd GSD7S54T-455BT 455.0 433.2 40.46 23.45 2
G-Star Pte Ltd GSD7S54T-455WT 455.0 433.2 40.46 23.45 2
G-Star Pte Ltd GSD8R48T-445BT 445.0 423.3 35.36 22.47 2
G-Star Pte Ltd GSD8R48T-445WT 445.0 423.3 35.36 22.47 2
G-Star Pte Ltd GSD7S54T-435BT 435.0 413.8 39.86 22.42 5
G-Star Pte Ltd GSD7S54T-435WT 435.0 413.8 39.86 22.42 5
G-Star Pte Ltd GSD7S54T-420BT 420.0 399.2 39.41 21.65 1
G-Star Pte Ltd GSD7S54T-420WT 420.0 399.2 39.41 21.65 1
G-Star Pte Ltd GSD7G54M-410BT 410.0 386.6 37.5 21.13 5
G-Star Pte Ltd GSD7G54M-410WT 410.0 386.6 37.5 21.13 5
G-Star Pte Ltd GSP7F54M(H)410BB 410.0 386.2 37.5 21.03 4
G-Star Pte Ltd GSP7F54M(H)410BW 410.0 386.2 37.5 21.03 4
G-Star Pte Ltd GSD7G54M-395BT 395.0 372.1 36.75 20.36 1
G-Star Pte Ltd GSD7G54M-395WT 395.0 372.1 36.75 20.36 1
G-Star Pte Ltd GSP7F54M(H)395BB 395.0 371.8 36.75 20.26 2
G-Star Pte Ltd GSP7F54M(H)395BW 395.0 371.8 36.75 20.26 2
G-Star Pte Ltd GSP6G60M(H)380BT 380.0 358.6 41.5 20.99 3
G-Star Pte Ltd GSP6G60M(H)380WT 380.0 358.6 41.5 20.99 3
G-Star Pte Ltd GSP6G60M(H)365BT 365.0 344.1 40.9 20.17 4
G-Star Pte Ltd GSP6G60M(H)365WT 365.0 344.1 40.9 20.17 4
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for G-Star Pte Ltd Solar Hardware?

Evaluate G-Star Pte Ltd CEC certifications (365–740W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

  • G-Star Pte Ltd certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
  • Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

G-Star Pte Ltd Module + Third-Party Inverter

Pair G-Star Pte Ltd modules (365–740W PV) with microinverters or string inverters rated above local cold-weather Voc.

Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical answers covering G-Star Pte Ltd CEC certifications, winter voltage headroom, and panel-busbar interconnection checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

How many G-Star Pte Ltd solar models are verified on the CEC list?

Our CEC archive indexes 66 G-Star Pte Ltd equipment records (66 module series and 0 inverter models) spanning 365–740W PV. Check local building department permit requirements for G Star Pte Ltd before finalizing component orders.

What should homeowners check before approving G-Star Pte Ltd equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

How efficient are G-Star Pte Ltd solar panels compared to CEC averages?

Across listed series, G-Star Pte Ltd modules show a median aperture efficiency of 22.2% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting G Star Pte Ltd.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
  4. CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.