G-Star Pte Ltd GSD8R48T-445WT is a 445.0 W STC (423.3 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 22.47% efficiency, 35.36 V Voc at 25 C, and 38.29 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 445.0 W
- PTC Wattage
- 423.3 W
- Voc @ 25C
- 35.36 V
- Efficiency
- 22.47%
How Does G-Star Pte Ltd GSD8R48T-445WT Compare Against Peer CEC Listings?
Solar engineering breakdown for G-Star Pte Ltd GSD8R48T-445WT: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from G-Star Pte Ltd and peers, G-Star Pte Ltd GSD8R48T-445WT stands 35.0 W above the 410.0 W Mono-c-Si median and strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,559-$2,560/yr in baseline US bill offset. Lower 35.36 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.
Where Does G-Star Pte Ltd GSD8R48T-445WT Fall Across Listed CEC Models?
Distribution marker showing G-Star Pte Ltd GSD8R48T-445WT (445.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define G-Star Pte Ltd GSD8R48T-445WT?
Dataset percentiles tracking G-Star Pte Ltd GSD8R48T-445WT power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for G-Star Pte Ltd GSD8R48T-445WT?
Benchmark highlights for G-Star Pte Ltd GSD8R48T-445WT covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 29.6% STC Output
445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.47% Aperture Efficiency
Power density 224.7 W/m2 (2.56 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 38.29 V at -10 C (574.4 V string) and 39.13 V at -20 C (15 max).
18 Panels = 8,010 W STC
Occupies 35.6 m2 (384 sq ft) producing 7,619 W PTC; NEC 690.8 OCPD floor is 24.62 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 35.36 * (1 + (-0.237/100) * (-10 - 25)) = 38.29 V | OCPD = 1.56 * 15.78 = 24.62 A
Inputs from CEC Modules.csv for G-Star Pte Ltd GSD8R48T-445WT: Voc=35.36 V, beta_Voc=-0.237%/C, Isc=15.78 A, STC=445.0 W, Area=1.98 m2.
Result: 15 panels max on 600 V (574.4 V); 18 panels for 8 kW (384 sq ft).
What Are the Published CEC Specifications for G-Star Pte Ltd GSD8R48T-445WT?
Official CEC datasheet figures for G-Star Pte Ltd GSD8R48T-445WT (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 445.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 423.3 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 35.36 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.78 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.65 V / 15.01 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.237 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.47% (1.98 m2) | Array roof footprint density |
| Cell Count & Technology | 16 cells (Mono-c-Si) | Monofacial backsheet |
How Many G-Star Pte Ltd GSD8R48T-445WT Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many G-Star Pte Ltd GSD8R48T-445WT modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.23 kW | 298 sq ft | $1,559 | $2,637 |
| 8 kW Class | 18 | 8.01 kW | 384 sq ft | $2,005 | $3,390 |
| 10 kW Class | 23 | 10.23 kW | 490 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This G-Star Pte Ltd Series?
Consolidated G-Star Pte Ltd wattage variants sharing the G-Star Pte Ltd GSD8R48T-445WT mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| G-Star Pte Ltd GSD8R48T-440WT | 440.0 W | 418.4 W | 35.15 V | 29.42 V | 22.22% |
| G-Star Pte Ltd GSD8R48T-445WT | 445.0 W | 423.3 W | 35.36 V | 29.65 V | 22.47% |
How Many G-Star Pte Ltd GSD8R48T-445WT Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on G-Star Pte Ltd GSD8R48T-445WT (38.29 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 39.13 V | 15 panels | 587.0 V | 25 panels |
| -10 C (14 F) | 38.29 V | 15 panels | 574.4 V | 26 panels |
| 0 C (32 F) | 37.46 V | 16 panels | 599.4 V | 26 panels |
| 25 C (77 F STC) | 35.36 V | 16 panels | 565.8 V | 28 panels |
Which Cross-Brand Solar Modules Compare Closest to G-Star Pte Ltd GSD8R48T-445WT?
Competing CEC solar panels closest to G-Star Pte Ltd GSD8R48T-445WT in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS62-48TM-440H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS62-48TM-440H CSI Solar Co Ltd |
440.0 W | -5.0 W | 35.4 V | 22.8% | 94.9% |
| ELITE Solar ET-NR48TBH440GB ELITE Solar |
440.0 W | -5.0 W | 35.29 V | 22.0% | 95.0% |
| ELITE Solar ET-NR48TBH440GL ELITE Solar |
440.0 W | -5.0 W | 35.29 V | 22.0% | 95.0% |
| CSI Solar Co Ltd CS61-54TM-440H CSI Solar Co Ltd |
440.0 W | -5.0 W | 38.5 V | 22.22% | 94.7% |
What Are the Design Limits and Best-Fit Uses for G-Star Pte Ltd GSD8R48T-445WT?
Evaluate G-Star Pte Ltd GSD8R48T-445WT (445.0 W STC, 35.36 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), G-Star Pte Ltd GSD8R48T-445WT reaches 39.13 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 384 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (384 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of G-Star Pte Ltd GSD8R48T-445WT carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
G-Star Pte Ltd GSD8R48T-445WT 8 kW Residential Fit
Needs 18 modules (384 sq ft) with a 25 A string OCPD, offsetting ~$2,005/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare CSI Solar Co Ltd CS62-48TM-440H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 423.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for G-Star Pte Ltd GSD8R48T-445WT by G-Star Pte Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for G-Star Pte Ltd GSD8R48T-445WT?
Multiplying G-Star Pte Ltd GSD8R48T-445WT's 15.78 A short-circuit current by 1.56 equals 24.62 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can G-Star Pte Ltd GSD8R48T-445WT pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 38.29 V cold Voc at 14 F and handles 15.78 A Isc; string inverters cap G-Star Pte Ltd GSD8R48T-445WT at 15 panels on 600 V.
Is G-Star Pte Ltd GSD8R48T-445WT eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of G-Star Pte Ltd GSD8R48T-445WT rely on utility bill offset (~$2,005/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)